3. Instruction Set<br />

API Mnemonic Operands Function<br />

156 D ZRN Zero return<br />

Controllers<br />

<strong>ES2</strong>/<strong>EX2</strong> <strong>SS2</strong> <strong>SA2</strong> <strong>SX2</strong><br />

SE<br />

Type Bit Devices Word Devices Program Steps<br />

OP X Y M S K H KnX KnY KnM KnS T C D E F DZRN: 17 steps<br />

S 1 * * * * * * * * * *<br />

S 2 * * * * * * * * * *<br />

S 3 *<br />

D *<br />

PULSE 16-bit 32-bit<br />

<strong>ES2</strong>/<strong>EX2</strong> <strong>SS2</strong> <strong>SA2</strong><br />

<strong>SA2</strong><br />

<strong>SA2</strong><br />

<strong>SX2</strong> <strong>ES2</strong>/<strong>EX2</strong> <strong>SS2</strong> <strong>SX2</strong> <strong>ES2</strong>/<strong>EX2</strong> <strong>SS2</strong><br />

SE SE SE <strong>SX2</strong><br />

Operands:<br />

S 1 : Target frequency for zero return S 2 : JOG frequency for DOG S 3 : input device for DOG D:<br />

Pulse output device<br />

Explanations:<br />

1. S 1 (zero return speed): max. 100kHz. S 2 (JOG speed for DOG) has to be lower than S 1. JOG<br />

speed for DOG also refers to the start frequency.<br />

2. S 3 and D operands have to be used as an input/output set according to the table below, i.e. when<br />

S 3 is specified as X4, D has to be specified as Y0; also when S 3 is specified as X6, D has to be<br />

specified as Y2.<br />

3. M1307 enables (ON) / disables (OFF) left limit switch of CH0 (Y0, Y1) and CH1 (Y2, Y3). M1307<br />

has to be set up before the instruction executes. M1305 and M1306 can reverse the pulse output<br />

direction on Y1 and Y3 and have to be set up before instruction executes. Associated left limit<br />

switch for CH0 (Y0, Y1) is X5; associated left limit switch for CH1 (Y2, Y3) is X7. All functions,<br />

input points and output points are arranged as follows:<br />

Channel<br />

Input<br />

CH0(Y0,Y1) CH1(Y2,Y3) Remark<br />

DOG point X4 X6<br />

Left limit switch (M1307 = ON) X5 X7<br />

Reverse pulse output direction M1305 M1306<br />

Zero point selection M1106 M1107<br />

Please refer to point<br />

7 for the explanation.<br />

M1346=On<br />

Please refer to point<br />

Y4<br />

Y5<br />

Start output clear signals<br />

8 for the explanation.<br />

D1312 != 0<br />

D1312 != 0<br />

M1308 = Off<br />

(seeking Z-phase signal)<br />

X2<br />

X3<br />

M1308 = On<br />

(outputting the designated number of<br />

pulses)<br />

Please refer to point<br />

9 for the explanation.<br />

Please refer to<br />

point 10 for the<br />

explanation.<br />

3-363