Special register<br />

D1168<br />

D1256~D1295<br />

Function<br />

The specific end word to be detected for RS instruction to execute an<br />

interruption request (I150) on COM2 (RS-485).<br />

Supported communication instruction: RS<br />

For COM2 RS-485 MODRW instruction. D1256~D1295 store the sent<br />

data of MODRW instruction. When MODRW instruction sends out data,<br />

the data will be stored in D1256~D1295. Users can check the sent data<br />

in these registers.<br />

Supported communication instruction: MODRW<br />

D1296~D1311<br />

For COM2 RS-485 MODRW instruction. D1296~D1311 store the<br />

converted hex data from D1070 ~ D1085 (ASCII). PLC automatically<br />

converts the received ASCII data in D1070 ~ D1085 into hex data.<br />

Supported communication instruction: MODRW<br />

3. PLC COM3 RS-485: Associated flags (Auxiliary relays) and special registers (Special D) for<br />

communication instructions RS / MODRW and FWD / REV / STOP / RDST / RSTEF when<br />

M1177 = ON.<br />

Flag Function Action<br />

M1136<br />

M1320<br />

M1316<br />

M1317<br />

M1318<br />

COM3 retain communication settings. Communication settings will<br />

be reset (changed) according to the content in D1109 after every<br />

scan cycle. Users can set ON M1136 if the communication protocol<br />

requires to be retained. When M1136 = ON, communication settings<br />

will not be reset (changed) when communication instructions are<br />

being processed, even if the content in D1109 is changed<br />

COM3 ASCII / RTU mode selection. ON : RTU mode, OFF: ASCII<br />

mode.<br />

COM3 sending request. Before executing communication<br />

instructions, users need to set M1316 to ON by trigger pulse, so that<br />

the data sending and receiving will be started. When the<br />

communication is completed, PLC will reset M1316 automatically.<br />

Data receiving ready. When M1317 is ON, PLC is ready for data<br />

receiving.<br />

COM3 data receiving completed.<br />

User<br />

sets and<br />

resets<br />

User<br />

sets and<br />

resets<br />

User<br />

sets,<br />

system<br />

resets<br />

System<br />

sets<br />

System<br />

sets,<br />

user<br />

resets<br />