<strong>DVP</strong>-<strong>ES2</strong>/<strong>EX2</strong>/<strong>SS2</strong>/<strong>SA2</strong>/<strong>SX2</strong>/SE <strong>Operation</strong> <strong>Manual</strong> - Programming<br />

overflow<br />

0 1 2 3 4 5 6 7 8 9 number key<br />

BCD value 1-digit BCD code<br />

10 3 10 2 10 1 10 0<br />

BCD value<br />

BIN value<br />

D0<br />

160. As shown in the timing diagram below, four keys connected with X35, X33, X31 and X30 are<br />

pressed in order. Therefore, the number 5,301 is generated and stored in D0. 9,999 is the<br />

maximum value allowed for D0. If the entered number exceeds the available range, the<br />

highest digit performs overflow.<br />

161. When X35 is pressed, M15 remains ON until another key is pressed and the rule applies to<br />

other inputs.<br />

162. M20 = ON when any of the keys is pressed.<br />

163. When X20 is OFF, the value in D0 remains unchanged but M10~M20 will be OFF.<br />

X30<br />

3<br />

X31<br />

4<br />

X33<br />

2<br />

X35 1<br />

M10<br />

M11<br />

M13<br />

M15<br />

Key output<br />

signal<br />

M20<br />

1 2 3 4<br />