3. Instruction Set<br />

Points to note:<br />

1. When the calculation results exceed the max frequency of PLC, the output frequency will<br />

be set as 0.<br />

2. When the total of ramp-up and ramp-down time exceeds the total time for operation, PLC<br />

will change the total time for operation (S+2) into “ramp-up time (S+3) + ramp-down<br />

time (S+4) + 1” automatically.<br />

Explanation on operands:<br />

S+0, S+1: Total number of pulses for operation (32-bit)<br />

S+2: Total time for operation (unit: ms)<br />

S+3: Ramp-up time (unit: ms)<br />

S+4: Ramp-down time(unit: ms)<br />

D+0, D+1: Optimal max output frequency (unit: Hz) (32-bit)<br />

D+2: Optimal start frequency (Unit: Hz)<br />

n: Reserved<br />

K11: Conversion from Local Time to Local Sidereal Time<br />

Unlike the common local time defined by time zones, local sidereal time is calculated based on<br />

actual longitude. The conversion helps the user obtain the more accurate time difference of<br />

each location within the same time zone.<br />

Explanation on operands:<br />

S+0, S+1: Longitude (32-bit floating point value; East: positive, West: negative)<br />

S+2: Time zone (16-bit integer; unit: hour)<br />

S+3~ S+8: Year, Month, Day, Hour, Minute, Second of local time (16-bit integer)<br />

D+0~D+5: Year, Month, Day, Hour, Minute, Second of the converted local sidereal time (16-bit<br />

integer)<br />

n: Reserved<br />

Example:<br />

Input: Longitude F121.55, Time zone: +8, Local time: AM 8:00:00, Jan/6/2011<br />

Conversion results: AM 8:06:12, Jan/6/2011<br />

K12: Proportional Value Calculation Function of Multi-point Areas (16-bit values)<br />

Explanation on operands (16-bit values):<br />

S: input value<br />

S+1, S+2….. S+n: set values of multi-point areas. S+1 must be the minimum value, S+2 must<br />

be larger than S+1 and so on. Therefore, S+n must be the maximum value.<br />

D: output value gotten from the proportional value calculation<br />

D+1, D +2 … D+n: the range of values gotten from the proportional value calculation<br />