Flag explanation:<br />

M1040:<br />

Disable step transition. When M1040 = ON, all motion of step points are disabled.<br />

91. <strong>Manual</strong> operation mode: M1040 remains ON in manual mode.<br />

92. Zero return mode/one cycle operation mode: M1040 remains ON in the interval after Auto<br />

Stop and before Auto Start is pressed.<br />

93. Step operation mode: M1040 remians ON until Auto Start is pressed.<br />

94. Continuous operation mode: When PLC goes from STOP→RUN, M1040 = ON. When Auto<br />

Start is pressed, M1040 turns OFF.<br />

M1041:<br />

Step transition starts. This special M indicates the transition from step point S2 to the next step<br />

point.<br />

95. <strong>Manual</strong> operation mode/Zero return mode: M1041 remians OFF.<br />

96. Step operation mode/One cycle operation mode: M1041 = ON when Auto Start is pressed.<br />

97. Continuous operation mode: M1041 stays ON when Auto Start is pressed and turns OFF<br />

when Auto Stop is pressed.<br />

M1042:<br />

Enable pulse operation: When Auto Start is pressed, PLC sents out pulse once for operation. .<br />

M1043:<br />

Zero return completed: M1043 = ON indicates that zero return is completed.<br />

M1044:<br />

Zero point condition: In continuous operation mode, M1044 has to be ON as a condition for enabling<br />

step transition from S2 to the next step point.<br />

M1045:<br />

Disable “all output reset” function.<br />

• If the machine (not at the zero point) goes,<br />

- from manual (S0) to zero return (S1)<br />

- from auto (S2) to manual (S0)<br />

- from auto (S2) to zero return (S1)<br />

And<br />

M1045 = OFF, any of the S among D 1 ~ D 2 in action will be reset as well as the output Y.<br />

M1045 = ON, output Y will be retained but the step in action will be reset.<br />

• If the machine (at the zero point) goes from zero return (S1) to manual (S0), no matter M1045<br />

is ON or OFF, Y output will be retained but the step in action will be reset.<br />

3-158