3. Instruction Set<br />

Program Example 1:<br />

EI<br />

FEND<br />

I 001<br />

M1000<br />

SET<br />

M1347<br />

DPLSY K1000 K1000 Y0<br />

IRET<br />

I 101<br />

M1000<br />

SET<br />

M1524<br />

DPLSY K1000 K1000 Y2<br />

IRET<br />

END<br />

Explanations:<br />

a) Whenever I001 is triggered, Y0 will output 1,000 pulses; whenever I101 is triggered, Y2 will<br />

output 1,000 pulses.<br />

b) When pulse output is completed, there should be an interval of at least one scan cycle<br />

before next pulse output operation is triggered. .<br />

Program Example 2:<br />

X1<br />

X2<br />

SET<br />

M1347<br />

PLSY K1000 K1000 Y0<br />

END<br />

Explanation:<br />

When both X1 and X2 are ON, Y0 pulse output will operate continuously. However, there will be a<br />

delay of approx. 1 scan cycle every 1000 pulses.<br />