<strong>DVP</strong>-<strong>ES2</strong>/<strong>EX2</strong>/<strong>SS2</strong>/<strong>SA2</strong>/<strong>SX2</strong>/SE <strong>Operation</strong> <strong>Manual</strong> - Programming<br />

M1348: Auto reset Y1 when high speed pulse output completed<br />

M1524: Auto reset Y2 when high speed pulse output completed<br />

M1525: Auto reset Y3 when high speed pulse output completed<br />

M1538: Indicating pause status of Y0<br />

M1539: Indicating pause status of Y1<br />

M1540: Indicating pause status of Y2<br />

M1541: Indicating pause status of Y3<br />

36. Description of associated special D registers:<br />

D1030: Present number of Y0 output pulses (Low word).<br />

D1031: Present number of Y0 output pulses (High word).<br />

D1032: Present number of Y1 output pulses (Low word).<br />

D1033: Present number of Y1 output pulses (High word).<br />

D1336: Present number of Y2 output pulses (Low word).<br />

D1337: Present number of Y2 output pulses (High word).<br />

D1338: Present number of Y3 output pulses (Low word).<br />

D1339: Present number of Y3 output pulses (High word).<br />

D1220: Phase of the 1 st group pulse output (Y0,Y1), please refer to explanations of the<br />

instruction.<br />

D1221: Phase of the 2 nd group pulse output (Y2,Y3), please refer to explanations of the<br />

instruction.<br />

37. More explanations for M1347,M1348, M1524, M1525:<br />

Generally when pulse output is completed, PLSY instruction has to be reset so that the<br />

instruction can start pulse output one more time. When M1347, M1348, M1524 or M1525 is<br />

enabled, the associated output terminals (Y0~Y3) will be reset automatically when pulse<br />

output is completed, i.e. the PLSY instruction is reset. When PLC scans to PLSY instruction<br />

again, the pulse output starts automatically. In addition, PLC scans the 4 flags after END<br />

instruction, hence PLSY instruction in continuous pulse output mode requires a delay time of<br />

one scan cycle for next pulse output operation.<br />

The function is mainly used in subroutines or interrupts which require high speed pulse output.<br />

Here are some examples:<br />

3-140