3. Instruction Set<br />

API Mnemonic Operands Function<br />

57 D PLSY Pulse Output<br />

Controllers<br />

<strong>ES2</strong>/<strong>EX2</strong> <strong>SS2</strong> <strong>SA2</strong><br />

SE<br />

<strong>SX2</strong><br />

Type Bit Devices Word devices Program Steps<br />

OP X Y M S K H KnX KnY KnM KnS T C D E F PLSY: 7 steps<br />

S 1 * * * * * * * * * * * DPLSY: 13 steps<br />

S 2 * * * * * * * * * * *<br />

D *<br />

PULSE 16-bit 32-bit<br />

<strong>ES2</strong>/<strong>EX2</strong> <strong>SS2</strong> <strong>SA2</strong><br />

<strong>SA2</strong><br />

<strong>SA2</strong><br />

<strong>SX2</strong> <strong>ES2</strong>/<strong>EX2</strong> <strong>SS2</strong> <strong>SX2</strong> <strong>ES2</strong>/<strong>EX2</strong> <strong>SS2</strong><br />

SE SE SE <strong>SX2</strong><br />

Operands:<br />

S 1 : Pulse output frequency S 2 : Number of output pulses D: Pulse output device (Y0 ~ Y3<br />

available)<br />

Explanations:<br />

21. When PLSY instruction has been executed, the specified quantity of pulses S 2 will be output<br />

through the pulse output device D at the specified pulse output frequency S 1<br />

22. S 1 specifies the pulse output frequency<br />

Output frequency range of MPU<br />

Output Y0, Y2 Y1, Y3<br />

<strong>SS2</strong>: 0~10,000Hz<br />

16-bit instruction<br />

0~10,000Hz<br />

range<br />

<strong>ES2</strong>/<strong>EX2</strong>/<strong>SA2</strong>/<strong>SX2</strong>/SE: 0~32,767 Hz<br />

<strong>SS2</strong>: 0~10,000Hz<br />

32-bit instruction<br />

0~10,000Hz<br />

<strong>ES2</strong>/<strong>EX2</strong>/<strong>SA2</strong>/<strong>SX2</strong>/SE: 0~100,000 Hz<br />

If frequency equals or smaller than 0Hz is specified, pulse output will be disabled.<br />

If frequency bigger than max frequency is specified, PLC will output with max frequency.<br />

23. S 2 specifies the number of output pulses.<br />

16-bit instruction: -32,768~32,767. 32-bit instruction: -2,147,483,648~2,147,483,647.<br />

When S 2 is specified as K0, the pulse will be output continuously regardless of the limit of<br />

pulse number.<br />

24. When D1220/D1221 = K1 or K2, the positive/negative sign of S 2 denotes pulse output direction<br />

(Positive/negative).<br />