3. Instruction Set<br />

*1: Y1 is dual output. When M0 is OFF, it is controlled by M1. When M0 is ON, M12 will control Y1<br />

*2: When timer that subroutine used (T184~T199) executes first and then CJ instruction is<br />

executed, the timer will keep counting. After the timer reaches the set value, output contact of<br />

timer will be ON.<br />

*3: When high-speed counters (C235~C254) executes first and then CJ instruction is executed,<br />

the counter will keep counting and its associated output status remains.<br />

Y1 is a dual output. When M0 = OFF, Y1 is controlled by M1. M0 = ON, Y1 is controlled by M12.<br />

P0<br />

P63<br />

M0<br />

M1<br />

M2<br />

M3<br />

M4<br />

M5<br />

M6<br />

M7<br />

M10<br />

M11<br />

M0<br />

M12<br />

M13<br />

CJ P0<br />

Y1<br />

M20<br />

S1<br />

TMR T0 K10<br />

RST T240<br />

TMR T240 K1000<br />

RST C0<br />

CNT C0 K20<br />

MOV K3 D0<br />

CJ P63<br />

Y1<br />

RST T240<br />

RST<br />

RST<br />

C0<br />

D0<br />

END<br />

3-45