2. Programming Concepts<br />

e) Commands of VFD c an be specified by changing the value in D1496, e.g. D1496 =<br />

H12=>VFD forward operation; D1496 = H1=> VFD stops)<br />

f) Frequency of VFD can be specified by ch anging the value in D1497, e.g. D1497 = K5000, set<br />

VFD frequency as 50kHz.<br />

g) In addition to VFD AC motor drives, devices support MODBUS protocol such as DTA/DTB<br />

temperature controllers and ASDA servo drives can also be connected as Slaves. Up to 16<br />

Slaves can be connected.<br />

13. D1354 is PLC link scan cycle with unit is 1ms and max. display value is K32000. D1354 = K0<br />

when PLC Link stops or when the first scan is completed.<br />

2-83