2. Programming Concepts<br />

Function Group ID of right side modules on <strong>ES2</strong>/<strong>EX2</strong><br />

Number<br />

D1320~ D1327<br />

Contents:<br />

When right side modules are connected on <strong>ES2</strong>/<strong>EX2</strong>, the ID of each I/O module will be stored in<br />

D1320~D1327 in connection order.<br />

ID of each special module:<br />

Name ID (HEX) Name ID (HEX)<br />

<strong>DVP</strong>04AD-E2 H’0080 <strong>DVP</strong>06XA-E2 H’00C4<br />

<strong>DVP</strong>02DA-E2 H’0041 <strong>DVP</strong>04PT-E2 H’0082<br />

<strong>DVP</strong>04DA-E2 H’0081 <strong>DVP</strong>04TC-E2 H’0083<br />

Function Group ID of left side modules on <strong>SA2</strong>/<strong>SX2</strong><br />

Number<br />

D1386~D1393<br />

Contents:<br />

When left side modules are connected on <strong>SA2</strong>/<strong>SX2</strong>, the ID of each I/O module will be stored in<br />

D1386~D1393 in connection order.<br />

ID of each special module:<br />

Name ID (HEX) Name ID (HEX)<br />

<strong>DVP</strong>04AD-SL H’4480 <strong>DVP</strong>01HC-SL<br />

H’4120<br />

<strong>DVP</strong>04DA-SL H’4441 <strong>DVP</strong>02HC-SL H’4220<br />

<strong>DVP</strong>04PT-SL H’4402 <strong>DVP</strong>DNET-SL H’4131<br />

<strong>DVP</strong>04TC-SL H’4403 <strong>DVP</strong>EN01-SL H’4050<br />

<strong>DVP</strong>06XA-S L<br />

H’6404 <strong>DVP</strong>MDM-SL H’4040<br />

<strong>DVP</strong>01PU-SL H’4110 <strong>DVP</strong>COPM-SL H’4133<br />

Function Group Output clear signals when ZRN is completed<br />

Number<br />

M1346<br />

Contents:<br />

When M1346 = ON, PLC will output clear signals when ZRN is completed. The clear si gnals to Y0,<br />

Y1 will be sent by Y4 for 20ms, and the clear signals to Y2, Y3 will be sent by Y5 for 20ms.<br />

Function Group<br />

Number<br />

Contents:<br />

PLC LINK<br />

M1350-M1356, M1360-M1439, D1355-D1370, D1399, D1415-D1465, D1480-<br />

D1991<br />

1. PLC LINK supports COM2 (RS-485) with communication of up to 16 slaves and access of up<br />

to 50 words.<br />

2. Special D and special M corresponding to Slave ID1~ Slave ID8: (M1353 = OFF, access<br />

available for only 16 words)<br />