<strong>2010</strong><br />
<strong>New</strong> <strong>Products</strong><br />
<strong>COMTECH</strong><br />
<strong>New</strong> <strong>Products</strong><br />
<strong>2010</strong><br />
Good quality at a competitive<br />
price from Europe<br />
www.comtech.co.hu
About us<br />
Our company is certified by ISO9001. Reliability<br />
is guaranted by the closed control and test<br />
process. Every products comply with EU and<br />
CE standars. When making our offers we are<br />
trying to give the best possible delivery times<br />
to our customers as we have an appropriate<br />
stock and flexible employees.<br />
Our products are sold to the domestic and the<br />
European customers. We have representatives<br />
in many countries. Our most important references<br />
are: Magyar Telekom, Fibernet, UPC,<br />
Tarr, Siemens, Synergon, Smartcable and other<br />
hundreds of Hungarian and foreign users. Our<br />
company is a SCTE member too.<br />
For customers guidance and service we have a<br />
qualified team. You can find help also from our<br />
catalogue or webpage or user guides. We have<br />
20 years experience in CATV business and our<br />
effort is to be your reliable and competitive<br />
supplier.<br />
Comtech Ltd. was founded in 1990 as a 100<br />
percent Hungarian private property company.<br />
The company produces cable television equipments.<br />
Our premise and production area is<br />
situated in Hungary, Gyôr. The number of employees<br />
is around 50.<br />
We produce the total range of active HFC elements,<br />
for example: optical nodes and headend<br />
optical transmitters and receivers, trunk-, line-,<br />
house amplifiers. We also produce Headend RF<br />
signal organizer products which help to handle<br />
the return paths data transfer. Our most successful<br />
product is our network-management<br />
system which can be built in all of our products.<br />
It helps the economical and reliable operation of<br />
interactive HFC networks assured by „triple play”<br />
function.<br />
Our products are our own developments, they<br />
meet the most up-to-date requirements and<br />
their prices are very competitive. We also satisfy<br />
unique and special requests.<br />
HU11594Q
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
<strong>2010</strong><br />
<strong>New</strong> <strong>Products</strong><br />
Table of contents<br />
HEADEND OPTICAL PRODUCTS..........................................................................................2<br />
SFOR1000 Forward path optical receiver.............................................................................................................2<br />
OPTICAL NODES...............................................................................................................4<br />
MO1004 Optical node.......................................................................................................................................... 4<br />
MO1003 Optical node ......................................................................................................................................... 8<br />
FOR1000H Forward path optical receiver module..............................................................................................12<br />
FOR1000F Forward path optical receiver module..............................................................................................14<br />
DISTRIBUTION AMPLIFIERS.............................................................................................16<br />
MT1000 Series mini trunk amplifiers..................................................................................................................16<br />
MB1000 Series mini bridger amplifiers..............................................................................................................19<br />
LE1000 Series line amplifiers............................................................................................................................. 22<br />
MONITORING PRODUCTS.................................................................................................25<br />
Standard HMS transponders (Pre-liminary)........................................................................................................25<br />
NMT-COM4 Monitoring transponder module......................................................................................................27<br />
RBS622Q-C Return path amplifier module with monitoring option.....................................................................29<br />
NMT-HLW3 Monitoring transponder module for Harmonic optical nodes...........................................................30<br />
RSW-H4 Return path switch module into Harmonic HLN-384x optical node.......................................................32<br />
Specifications are subject to change without notice!<br />
1 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
HEADEND OPTICAL PRODUCTS<br />
SFOR1000 FORWARD PATH OPTICAL RECEIVER<br />
• Frequency range up to 1GHz<br />
• Connection to the Monitoring System<br />
• RF testpoint on the face<br />
• Redundant RF input for a secondary receiver<br />
• Display and knobs on the face<br />
• Excellent price/value ratio<br />
TECHNICAL SPECIFICATIONS ___________________________________________________________<br />
Optical parameters<br />
Wavelength [nm] 1280…1620<br />
Input optical power [dBm] (2)<br />
Return loss of the optical input [dB] > 45<br />
Equivalent input noise current [pA/√Hz] 7<br />
Optical connector<br />
RF parameters<br />
-10…+3<br />
SC/APC, EURO-<br />
2000, FC/APC<br />
Frequency range [MHz] 47 … 1000<br />
Impedance [Ω] 75<br />
Return loss [dB] > 16<br />
Output level control<br />
Output level setup range [dBmV] (1,2) 28…44<br />
AGC deviation [dB] ±1<br />
Flatness [dB] ±0,5<br />
Slope [dB] ±0,5<br />
RF testpoint [dB] -20±0,5<br />
Composite triple beat (CTB) [dBc] (3) > 72<br />
Composite second order (CSO) [dBc] (3) > 68<br />
General parameters<br />
Current consumption [mA] 350<br />
Power supply voltage [V] 24<br />
Power consumption [W] 8,5<br />
Temperature range [°C] 0…40<br />
Dimensions [mm]<br />
Weight [kg] 0,6<br />
OLC<br />
230x130x35<br />
Specifications are subject to change without notice!<br />
2 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
<strong>2010</strong><br />
<strong>New</strong> <strong>Products</strong><br />
(1) 4% OMI can be adjusted in 0,5dB steps<br />
(2) Recommended optical input and RF output power are indicated on the diagrams<br />
(3) Output level
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
OPTICAL NODES<br />
MO1004 OPTICAL NODE<br />
• Low noise optical receiver module<br />
• Return path optical transmitter module<br />
• Segmentation in forward and return path<br />
• HFC and Fiber Deep versions<br />
• 2 high-leveled RF outputs (splittable to 2x2)<br />
• 1GHz GaAs or GaN Power-doubler hybrids<br />
• Remote powered switching power supply<br />
• Monitoring option<br />
GENERAL DESCRIPTION______________________________________________________________<br />
The optical node is available in different configurations. This depends on the configuration module which can be<br />
ordered. CM5 configuration module allows (2 transmitter and 2 receiver modules) the segmented operation<br />
mode in forward and return path too. Using CM6 configuration module – can be used 2 transmitter and 1<br />
receiver modules – you can realize the return path segmentation. CM7 configuration module uses 1<br />
transmitter and 1 receiver module – in this operation mode segmented operation is impossible. CM8<br />
configuration module enables the redundant operation in forward and return path with 2 transmitters and 2<br />
receivers. In basic configuration the device contains 1 optical receiver module (FOR1000H for HFC version or<br />
FOR1000F for Fiber Deep version). For the optical node FP, DFB or CWDM return path optical transmitter, another<br />
other receiver module as well as monitoring option can be added.<br />
TECHNICAL SPECIFICATIONS ___________________________________________________________<br />
Parameters of the optical receiver MO1004xH MO1004xF<br />
Bandwidth [MHz] 47...1000<br />
Wavelength [nm] 1290…1570<br />
Optical input level range [dBm] -5…+3 -8…+3<br />
Nominal optical input level [dBm] 0 -3<br />
Return loss of the optical input [dB] > 45<br />
Equivalent input noise [pA/√Hz] 7<br />
RF level on the output of the receiver module (4% OMI) [dBµV] 79±1 76±1 @ 47MHz<br />
86±1 @ 1GHz<br />
(862MHz)<br />
TILT [dB] 0 10 (5)<br />
Type of the optical connector<br />
SC/APC, FC/APC, EURO2000<br />
Specifications are subject to change without notice!<br />
4 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
<strong>2010</strong><br />
<strong>New</strong> <strong>Products</strong><br />
Parameters of the optical transmitter<br />
Bandwidth [MHz] 5-65<br />
Wavelength [nm]<br />
1310 or CWDM<br />
Optical input level range [mW] FP: 1, DFB: 2, CWDM: 2 or 4<br />
Type of the optical connector<br />
SC/APC, FC/APC, EURO-2000<br />
RF input level (OUT1,2,10% OMI) [dBµV] 78±1<br />
Flatness [dB] ±0,5<br />
Input return loss (40MHz -1,5 dB/octave) [dB] > 18<br />
Input impedance [Ω] 75<br />
RF level on the testpoint of the optical transmitter (1) [dBµV] 70+1/-2<br />
RF parameters MO1004Cx MO1004Dx<br />
Forward path gain [dB] (2) 38<br />
CTB [dB] -63 (3) -69 (4)<br />
XMOD [dB] -59 (3) -64 (4)<br />
CSO [dB] -64 (3) -70 (4)<br />
CIN [dB] - 60 (4)<br />
Output testpoint attenuation [dB] 30±1<br />
Forward path RF testpoint attenuation [dB] (2) 0±1<br />
Flatness [dB] ±0,7<br />
Type of the output amplifier-module GaAs PD hybrid GaN PD hybrid<br />
Number of active outputs 2<br />
Output diplex filter [MHz] 30/47 or 65/85<br />
Output return loss (40MHz -1,5 dB/octave) [dB] > 18<br />
Output impedance [Ω] 75<br />
Isolation between segments (forward path) [dB] > 65<br />
Isolation between segments (return path) [dB] > 75<br />
Breakpoint frequency of TILT [MHz] 606, 750, 862, 1000<br />
Return path<br />
passive<br />
General parameters<br />
Screening factor [dB] 80<br />
Maximum power consumption [W] 51<br />
Power supply voltage [V-AC] 30...65; 35...90<br />
Maximum current feed-through [A] 10<br />
Hum modulation [dB] 70<br />
Degree of protection IP 65<br />
Temperature range [°C] -20 … +50<br />
Type of the RF connector 5/8”<br />
Dimensions [mm]<br />
275x200x175<br />
Weight [kg] 5,0<br />
(1) 10% optical modulation index<br />
(2) Gain parameters are relative to FOR output level<br />
(3) 132 ch.flat, Vout:44dBmV<br />
(4) 79 ch. 7dB tilted, Vout:50dBmV @ 550MHz, 75digital ch. -6dB offset<br />
(5) TILT breakpoint frequency jumper adjustable - 862MHz or 1GHz<br />
Specifications are subject to change without notice!<br />
5 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
BLOCK DIAGRAM___________________________________________________________________<br />
SUPPLY<br />
60V AC<br />
AC FUSE<br />
SWITCHING POWER SUPPLY<br />
STATUS MONITORING SYSTEM<br />
OUT 1<br />
SURGE<br />
PROT<br />
AC TP<br />
DC TP<br />
+ 24V DC<br />
DC IND<br />
SURGE<br />
PROT<br />
OUT 2<br />
TP<br />
0 dB<br />
TP<br />
0 dB<br />
AC<br />
BYPASS<br />
AC<br />
BYPASS<br />
POST AMP<br />
ATT<br />
INT EQ<br />
INT EQ<br />
ATT<br />
POST AMP<br />
AC FUSE<br />
10 A<br />
AC FUSE<br />
10 A<br />
TP<br />
-30dB<br />
TP<br />
-30dB<br />
SP2<br />
H<br />
L<br />
DIPLEX<br />
FILTER<br />
PRE AMP<br />
PRE AMP<br />
SWITCH<br />
ATT<br />
DIPLEX<br />
FILTER<br />
H<br />
L<br />
SP<br />
DC<br />
or<br />
TP<br />
-30dB<br />
TP<br />
-30dB<br />
AC FUSE<br />
10 A<br />
AC FUSE<br />
10 A<br />
ATT<br />
AC<br />
BYPASS<br />
SWITCH<br />
AC<br />
BYPASS<br />
OUT 4<br />
OUT 3<br />
SURGE<br />
PROT<br />
CONFIGURATION MODULE<br />
RF<br />
SURGE<br />
PROT<br />
CM5<br />
ROTxxx<br />
FOR1000x<br />
FOR1000x<br />
FULL SEGMENTATION<br />
ROTxxx<br />
CM6<br />
ROTxxx<br />
ROTxxx<br />
SEGMENTATION IN RETURN PATH<br />
FOR1000x<br />
CM7<br />
ROTxxx<br />
WITHOUT SEGMENTATION<br />
FOR1000x<br />
CM8<br />
ROTxxx<br />
ROTxxx<br />
FOR1000x<br />
REDUNDANCY<br />
FOR1000x<br />
Specifications are subject to change without notice!<br />
6 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
<strong>2010</strong><br />
<strong>New</strong> <strong>Products</strong><br />
ORDERING INFORMATION_____________________________________________________________<br />
M O 1 0 0 4 X X - X X - X X<br />
Amplifier-module type<br />
C GaAs<br />
D GaN<br />
Forward path module<br />
H FOR1000H (Standard type)<br />
F FOR1000F (Fiber Deep type)<br />
Optical connector<br />
SA SC/APC (Recommended type)<br />
FA FC/APC<br />
EU EURO-2000<br />
Type of the diplex filter<br />
30 Internal 30/47MHz diplex filter<br />
65 Internal 65/85MHz diplex filter<br />
Option Required modules Ordering codes<br />
Monitoring option 1pc NMT-F, 2pcs RSW2-A NMT-Fxx, RSW2-A<br />
CONFIGURATION POSSIBILITIES_________________________________________________________<br />
Segmentation in forward and return path Required modules Ordering codes<br />
Configuration module 1pc CM5 configuration module CM5<br />
Return path optical transmitter(s) 2pcs ROT61F, ROT62D, ROT62C ROT6xx-xxxx-xx<br />
Forward path optical receiver(s) 2pcs FOR1000x (one is contained) FOR1000H or FOR1000F<br />
Segmentation in return path Required modules Ordering codes<br />
Configuration module 1pc CM6 configuration module CM6<br />
Return path optical transmitter(s) 2pcs ROT61F, ROT62D, ROT62C ROT6xx-xxxx-xx<br />
Forward path optical receiver 1pc FOR1000x (contained) FOR1000H or FOR1000F<br />
No segmentation Required modules Ordering codes<br />
Configuration module 1pc CM7 configuration module CM7<br />
Return path optical transmitter(s) 1pc ROT61F, ROT62D, ROT62C ROT6xx-xxxx-xx<br />
Forward path optical receiver 1pc FOR1000x (contained) FOR1000H or FOR1000F<br />
Redundancy in forward and return path Required modules Ordering codes<br />
Configuration module 1pc CM8 configuration module CM8<br />
Return path optical transmitter(s) 2pcs ROT61F, ROT62D, ROT62C ROT6xx-xxxx-xx<br />
Forward path optical receiver(s) 2pcs FOR1000x (one is contained) FOR1000H or FOR1000F<br />
Specifications are subject to change without notice!<br />
7 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
MO1003 OPTICAL NODE<br />
• Low noise optical receiver module<br />
• Return path optical transmitter module<br />
• Possibility of segmentation and redundancy<br />
• Pull-out internal casting tray electronics<br />
• HFC and Fiber Deep versions<br />
• 3 high-leveled RF outputs<br />
• 1GHz GaAs or GaN Power-doubler hybrids<br />
• Remote powered switching power supply<br />
• Status monitoring option<br />
GENERAL DESCRIPTION______________________________________________________________<br />
The optical node is available in different configurations. This depends on the configuration module which can be<br />
ordered. In normal configuration node contains the CM1 configuration module which allows the operation of 1<br />
transmitter and 1 receiver. The second configuration allows the redundant operation by the CM2 configuration<br />
module. With this module 2 transmitters and 2 receivers can be operated. With CM3 configuration module you<br />
can realize the segmentation. This module supports 3 transmitters and 1 receiver. With CM4 configuration<br />
module you can realize the partial segmentation. This module supports 2 transmitters and 1 receiver. The<br />
block- diagrams of these modules can be seen under the node's block- diagram.<br />
In basic configuration the device contains 1 receiver module (FOR1000H for HFC version or FOR1000F for<br />
Fiber Deep version). For the optical node an FP, DFB or CWDM-ITU return path optical transmitter, another optical<br />
receiver module as well as the monitoring option can be ordered.<br />
TECHNICAL SPECIFICATIONS ___________________________________________________________<br />
Parameters of the optical receiver MO1003xH MO1003xF<br />
Bandwidth [MHz] 47...1000<br />
Wavelength [nm] 1290…1570<br />
Optical input level range [dBm] -5…+3 -8…+3<br />
Nominal optical input level [dBm] 0 -3<br />
Return loss of the optical input [dB] > 45<br />
Equivalent input noise [pA/√Hz] 7<br />
RF level on the output of the receiver module (4% OMI) [dBµV] 79±1 76±1 @ 47MHz<br />
86±1 @ 1GHz<br />
(862MHz)<br />
TILT [dB] 0 10 (5)<br />
Type of the optical connector<br />
SC/APC, FC/APC, EURO2000<br />
Specifications are subject to change without notice!<br />
8 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
<strong>2010</strong><br />
<strong>New</strong> <strong>Products</strong><br />
Parameters of the optical transmitter<br />
Bandwidth [MHz] 5-65<br />
Wavelength [nm]<br />
1310 or CWDM<br />
Output power [mW] FP: 1, DFB: 2, CWDM: 2, 4<br />
Type of the optical connector<br />
SC/APC, FC/APC, EURO-2000<br />
RF input level (OUT1,2,3 10% OMI) [dBµV] 78±1<br />
Flatness [dB] ±0,5<br />
Input return loss (40 MHz -1,5 dB/octave) [dB] > 18<br />
Input impedance [Ω] 75<br />
RF level on the testpoint of the optical transmitter (1) [dBµV] 70+1/-2<br />
RF parameters MO1003Cx MO1003Dx<br />
Forward path gain [dB] (2) 36<br />
CTB [dB] -63 (3) -69 (4)<br />
XMOD [dB] -59 (3) -64 (4)<br />
CSO [dB] -64 (3) -70 (4)<br />
CIN [dB] - 60 (4)<br />
Output testpoint attenuation [dB] 30±1<br />
Forward path RF testpoint attenuation (TP4) [dB] (2) 0±1<br />
Flatness [dB] ±0,7<br />
Type of the output amplifier-module GaAs PD hybrid GaN PD hybrid<br />
Number of active outputs 3<br />
Output diplex filter [MHz] 30/47 or 65/85<br />
Output return loss (40 MHz -1,5 dB/octave) [dB] > 18<br />
Output impedance [Ω] 75<br />
Breakpoint frequency of TILT [MHz] 606, 750, 862, 1000<br />
Return path<br />
passive<br />
General parameters<br />
Screening factor [dB] 80<br />
Maximum power consumption [W] 56<br />
Power supply voltage [V-AC] 30...65; 35...90<br />
Maximum current feed-through [A] 10<br />
Hum modulation [dB] 70<br />
Degree of protection IP 65<br />
Temperature range [°C]<br />
-20…+50<br />
Type of the RF connector 5/8”<br />
Dimensions [mm]<br />
275x172x170<br />
Weight [kg] 3,9<br />
(1) 10% optical modulation index<br />
(2) Gain parameters are relative to FOR output level<br />
(3) 132 ch.flat, Vout:44dBmV<br />
(4) 79 ch. 7dB tilted, Vout:50dBmV @ 550MHz, 75digital ch. -6dB offset<br />
(5) TILT breakpoint frequency jumper adjustable - 862MHz or 1GHz<br />
Specifications are subject to change without notice!<br />
9 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
BLOCK DIAGRAM___________________________________________________________________<br />
SUPPLY<br />
60V AC<br />
AC FUSE<br />
SWITCHING POWER SUPPLY<br />
STATUS MONITORING SYSTEM<br />
SURGE<br />
PROT<br />
AC TP<br />
DC TP<br />
+ 24V DC<br />
POST AMP ATT INT EQ<br />
INT EQ ATT POST AMP<br />
OUT1 OUT 2<br />
DC IND<br />
SURGE<br />
PROT<br />
H<br />
H<br />
AC<br />
BYPASS<br />
L<br />
TP<br />
0dB<br />
L<br />
DIPLEX<br />
FILTER<br />
AC<br />
BYPASS<br />
ATT<br />
SWITCH<br />
ATT<br />
AC FUSE<br />
10 A<br />
TP<br />
-30dB<br />
TP<br />
-30dB<br />
AC FUSE<br />
10 A<br />
SWITCH<br />
AC FUSE<br />
10 A<br />
INT EQ<br />
ATT<br />
POST AMP<br />
TP<br />
-30dB<br />
H<br />
AC<br />
BYPASS<br />
PRE AMP<br />
L<br />
DIPLEX<br />
FILTER<br />
SWITCH<br />
ATT<br />
OUT 3<br />
CONFIGURATION MODULE<br />
RF<br />
SURGE<br />
PROT<br />
CM1<br />
ROTxxx<br />
NORMAL<br />
FOR1000x<br />
CM2<br />
ROTxxx<br />
ROTxxx<br />
REDUNDANCY<br />
FOR1000x<br />
FOR1000x<br />
CM3<br />
ROTxxx<br />
ROTxxx<br />
ROTxxx<br />
SEGMENTATION<br />
FOR1000x<br />
CM4<br />
ROTxxx<br />
PARTIAL<br />
SEGMENTATION<br />
ROTxxx<br />
FOR1000x<br />
Specifications are subject to change without notice!<br />
10 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
<strong>2010</strong><br />
<strong>New</strong> <strong>Products</strong><br />
ORDERING INFORMATION_____________________________________________________________<br />
M O 1 0 0 3 X X - X X - X X<br />
Amplifier-module type<br />
C GaAs<br />
D GaN<br />
Forward path module<br />
H FOR1000H (Standard type)<br />
F FOR1000F (Fiber Deep type)<br />
Optical connector<br />
SA SC/APC (Recommended type)<br />
FA FC/APC<br />
EU EURO-2000<br />
Type of the diplex filter<br />
30 Internal 30/47MHz diplex filter<br />
65 Internal 65/85MHz diplex filter<br />
Option Required modules Ordering information<br />
Monitoring 1pc NMT-O, 3pcs RSW2-A NMT-Oxx, RSW2-A<br />
CONFIGURATION POSSIBILITIES_________________________________________________________<br />
Normal Required modules Ordering information<br />
Configuration module 1pc CM1 configuration module CM1<br />
Return path optical transmitter(s) 1pc ROT61F, ROT62D, ROT62C ROT6xx-xxxx-xx<br />
Forward path optical receiver 1pc FOR1000x (contained) FOR1000H or FOR1000F<br />
Redundant Required modules Ordering information<br />
Configuration module 1pc CM2 configuration module CM2<br />
Return path optical transmitter(s) 2pcs ROT61F, ROT62D, ROT62C ROT6xx-xxxx-xx<br />
Forward path optical receiver(s) 2pcs FOR1000 (one is contained) FOR1000H or FOR1000F<br />
Segmentated Required modules Ordering information<br />
Configuration module 1pc CM3 configuration module CM3<br />
Return path optical transmitter(s) 3pcs ROT61F, ROT62D, ROT62C ROT6xx-xxxx-xx<br />
Forward path optical receiver 1pc FOR1000x (contained) FOR1000H or FOR1000F<br />
Partially segmentated Required modules Ordering information<br />
Configuration module 1pc CM4 configuration module CM4<br />
Return path optical transmitter(s) 2pcs ROT61F, ROT62D, ROT62C ROT6xx-xxxx-xx<br />
Forward path optical receiver 1pc FOR1000x (contained) FOR1000H or FOR1000F<br />
Specifications are subject to change without notice!<br />
11 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
FOR1000H FORWARD PATH OPTICAL RECEIVER MODULE<br />
• SC/APC, EURO2000, FC/APC optical connector<br />
(optional)<br />
• Receiving wavelengths 1290-1620 nm<br />
• Temperature-compensated construction<br />
• Frequency range 47-1000 MHz<br />
• Connection to the Monitoring System<br />
• Monitoring of the input optical level<br />
• Standard HFC applications<br />
TECHNICAL SPECIFICATIONS ___________________________________________________________<br />
Parameters of the optical receiver<br />
FOR1000H<br />
Wavelength [nm] 1290…1620<br />
Optical input level range [dBm]<br />
-5…+3<br />
Optical return loss [dB] > 45<br />
Optical level (testpoint) [V/mW] 1<br />
Nominal optical input level [dBm] 0<br />
RF parameters<br />
Bandwidth [MHz] 47…1000<br />
Equivalent input noise [pA/Hz] 7<br />
Level control<br />
OLC<br />
Output level (4% OMI) [dBµV] 79<br />
Output level accuracy [dB] ±1<br />
Flatness [dB] ±0,7<br />
General parameters<br />
Current consumption [mA] 60<br />
Power supply voltage [V] +24<br />
Temperature range [°C]<br />
-40…+70<br />
Type of the optical connector<br />
SC/APC, EURO2000, FC/APC<br />
Specifications are subject to change without notice!<br />
12 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
<strong>2010</strong><br />
<strong>New</strong> <strong>Products</strong><br />
BLOCK DIAGRAM___________________________________________________________________<br />
FOR1000H<br />
OPTICAL<br />
INPUT<br />
O<br />
E<br />
ATT<br />
POWER<br />
SUPPLY<br />
MICRO<br />
CONTROLLER<br />
TP<br />
OPT Power<br />
ORDERING INFORMATION_____________________________________________________________<br />
F O R 1 0 0 0 H - X X<br />
Type of the optical connector<br />
SA SC/APC (Recommended type)<br />
FA FC/APC<br />
EU EURO2000<br />
In basic configuration the MO1003xH and MO1004xH contains 1 FOR1000H module. You have to buy other<br />
modules for segmented and redundant operation!<br />
Specifications are subject to change without notice!<br />
13 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
FOR1000F FORWARD PATH OPTICAL RECEIVER MODULE<br />
• SC/APC, EURO2000, FC/APC optical connector<br />
(variable)<br />
• Receiving wavelengths 1290-1620 nm<br />
• Temperature-compensated construction<br />
• Frequency range 47-1000 MHz<br />
• Connection to the Monitoring System<br />
• Monitoring of the input optical level<br />
• Fiber Deep version with higher output level<br />
TECHNICAL SPECIFICATIONS ___________________________________________________________<br />
Parameters of the optical receiver<br />
FOR1000F<br />
Wavelength [nm] 1290…1620<br />
Optical input level range [dBm]<br />
-8…+3<br />
Optical return loss [dB] > 45<br />
Optical level (testpoint) [V/mW] 1<br />
Nominal optical input level [dBm] -3<br />
RF parameters<br />
Bandwidth [MHz] 47…1000<br />
Equivalent input noise [pA/Hz] 7<br />
Level control<br />
OLC<br />
Output level @ 47MHz (4% OMI) [dBµV] 76<br />
Output level @ 1GHz (4% OMI) [dBµV] 86<br />
Output level accuracy [dB] ±1<br />
TILT [dB] (1) 10<br />
Flatness [dB] ±0,7<br />
General parameters<br />
Current consumption [mA] 90<br />
Power supply voltage [V] +24<br />
Temperature range [°C]<br />
-40…+70<br />
Type of the optical connector<br />
SC/APC, EURO2000, FC/APC<br />
(1) TILT breakpoint frequency jumper adjustable - 862MHz or 1GHz<br />
Specifications are subject to change without notice!<br />
14 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
<strong>2010</strong><br />
<strong>New</strong> <strong>Products</strong><br />
BLOCK DIAGRAM___________________________________________________________________<br />
OPTICAL<br />
INPUT<br />
O<br />
E<br />
ATT<br />
ATT<br />
EQ<br />
POWER<br />
SUPPLY<br />
MICRO<br />
CONTROLLER<br />
862MHz<br />
or<br />
1GHz<br />
TP<br />
OPT Power<br />
ORDERING INFORMATION_____________________________________________________________<br />
F O R 1 0 0 0 F - X X<br />
Type of the optical connector<br />
SA SC/APC (Recommended type)<br />
FA FC/APC<br />
EU EURO2000<br />
In basic configuration the MO1003xF and MO1004xF contains 1 FOR1000F module. You have to buy other modules<br />
for segmented and redundant operation!<br />
Specifications are subject to change without notice!<br />
15 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
DISTRIBUTION AMPLIFIERS<br />
MT1000 SERIES MINI TRUNK AMPLIFIERS<br />
• Outdoor aluminium casting case<br />
• Pull-out internal casting tray electronics<br />
• Internal diplex filters<br />
• One trunk, one bridger output (splittable)<br />
• Internal return path hybrid module<br />
• 1GHz GaAs or GaN Power-doubler hybrids<br />
• Remote powered switching power supply<br />
• Pilot control option<br />
• Return path noise switch-off option<br />
• Status monitoring option<br />
TECHNICAL SPECIFICATIONS ___________________________________________________________<br />
RF parameters MT10xxC-xx MT10xxD-xx<br />
Amplifier-module GaAs PD hybrid GaN PD hybrid<br />
Number of active outputs<br />
1 trunk, 1 bridger<br />
Forward path bandwidth [MHz] 47-1000 or 85-1000<br />
Return path bandwidth [MHz] 5-30 or 5-65<br />
Type of diplex filter [MHz] 30/47, 65/85 (1)<br />
Gain on trunk output [dB] 32, 36, 42 (1)<br />
Gain on bridger output [dB] 36, 40, 46 (1)<br />
Flatness [dB] ±0,5<br />
CTB [dB] -63 (3) -69 (4)<br />
XMOD [dB] -59 (3) -64 (4)<br />
CSO [dB] -64 (3) -70 (4)<br />
CIN [dB] - 60 (4)<br />
Manual level setup (2 dB steps) [dB] Plug-in 0-20<br />
Manual TILT setup (2 dB steps) [dB] Plug-in 0-22<br />
Breakpoint frequency of TILT [MHz] 302, 606, 750, 862, 1000<br />
ASG insertion loss (20°C) [dB] 6,5<br />
ASG control range [dB] ±4<br />
ASG flatness [dB] ±0,5<br />
Noise figure [dB] 7<br />
Testpoints' attenuation (inputs, outputs) [dB] -30±1<br />
Return loss (40 MHz -1,5 dB/octave) [dB] 18<br />
Return path gain [dB] 20<br />
Specifications are subject to change without notice!<br />
16 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
<strong>2010</strong><br />
<strong>New</strong> <strong>Products</strong><br />
CTB in return path [dB] -66 (2)<br />
CSO in return path [dB] -70 (2)<br />
Return path TILT (plug-in) [dB] 2, 4, 6, 8, 10<br />
Breakpoint frequency of TILT [MHz] 30, 65<br />
Connecting impedance [Ω] 75<br />
Bridger output splitter, directional coupler [dB] Plug-in 4, 8, 12, 16<br />
Screening factor [dB] 80<br />
General parameters<br />
Maximum power consumption [W] 38<br />
Power supply voltage [V] 30-65; 35-90<br />
Class of electric shock protection<br />
III.<br />
Maximum current feed-through [A] 10<br />
Hum modulation [dB] 70<br />
Degree of protection IP 65<br />
Temperature range [°C] -40 … +60<br />
Type of connector 5/8”<br />
Dimensions [mm]<br />
275x172x122<br />
Weight [kg] 3,5<br />
(1) The value of gain and the diplex filters can be found in the typechart<br />
(2) Measured with 7 channels load in case of 110dBμV output level<br />
(3) 132 ch.flat, Vout:44dBmV<br />
(4) 79 ch. 7dB tilted, Vout:50dBmV @ 550MHz, 75digital ch. -6dB offset<br />
BLOCK DIAGRAM___________________________________________________________________<br />
SUPPLY<br />
60V AC<br />
AC FUSE<br />
SWITCHING POWER SUPPLY<br />
STATUS MONITORING SYSTEM<br />
SURGE<br />
PROT<br />
AC TP<br />
DC TP<br />
DC PWR<br />
SURGE<br />
PROT<br />
+ 24V DC<br />
BRIDGE<br />
OUT1<br />
EQ1<br />
AT1<br />
PRE AMP AT2 EQ2 BRIDG. AMP<br />
AC<br />
BYPASS<br />
BEQ<br />
AC<br />
BYPASS<br />
F1<br />
AC FUSE<br />
10 A<br />
AC FUSE<br />
10 A<br />
F4<br />
TP1<br />
-30dB<br />
TP4<br />
-30dB<br />
H<br />
L<br />
DF1<br />
ASG<br />
AT3 EQ3<br />
ASG ATT<br />
STAT. MON.<br />
INTERFACE<br />
BRIDG. AMP<br />
DF3<br />
H<br />
L<br />
DF2<br />
H<br />
L<br />
TP2<br />
-30dB<br />
TP3<br />
-30dB<br />
F2<br />
AC FUSE<br />
10 A<br />
AC FUSE<br />
10 A<br />
F3<br />
AC<br />
BYPASS<br />
30, 65 MHz<br />
RSW1<br />
SD<br />
SP or<br />
DC<br />
AC<br />
BYPASS<br />
EQ4<br />
AT3<br />
REV AMP<br />
RELPF<br />
RSW2<br />
BRIDGE<br />
OUT 3<br />
REV. INJ<br />
-20dB<br />
BRIDGE<br />
OUT 2<br />
SURGE<br />
PROT<br />
RF<br />
SURGE<br />
PROT<br />
Specifications are subject to change without notice!<br />
17 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
ORDERING INFORMATION_____________________________________________________________<br />
M T 1 0 X X X - X X R X X<br />
Return path gain<br />
20 20 dB<br />
25 25 dB<br />
Type of the diplex filter<br />
30 Internal 30/47MHz diplex filter<br />
65 Internal 65/85MHz diplex filter<br />
Gain<br />
32 Trunk: 32dB / Bridger: 36dB<br />
36 Trunk: 36dB / Bridger: 40dB<br />
42 Trunk: 42dB / Bridger: 46dB<br />
Amplifier-module type<br />
C GaAs<br />
D GaN<br />
Options<br />
ASG option<br />
Monitoring option<br />
Required modules<br />
1pc ASG 535-C, 1pc BEQxxx-A, 1pc ATxx<br />
1pc NMT-F, 2pc RSW2-A<br />
Specifications are subject to change without notice!<br />
18 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
<strong>2010</strong><br />
<strong>New</strong> <strong>Products</strong><br />
MB1000 SERIES MINI BRIDGER AMPLIFIERS<br />
• Outdoor aluminium casting case<br />
• Pull-out internal casting tray electronics<br />
• Internal diplex filters<br />
• Two active outputs (either of them is splittable)<br />
• Internal return path hybrid module<br />
• 1GHz GaAs or GaN Power-doubler hybrids<br />
• Remote powered switching power supply<br />
• Pilot control option<br />
• Return path noise switch-off option<br />
• Status monitoring option<br />
TECHNICAL SPECIFICATIONS ___________________________________________________________<br />
RF parameters MB10xxC-xx MB10xxD-xx<br />
Amplifier-module GaAs PD hybrid GaN PD hybrid<br />
Number of active outputs<br />
2 bridgers<br />
Forward path bandwidth [MHz] 47-1000 or 85-1000<br />
Return path bandwidth [MHz] 5-30 or 5-65<br />
Type of diplex filter [MHz] 30/47, 65/85 (1)<br />
Forward path gain [dB] 38, 42, 48 (1)<br />
Flatness [dB] ±0,5<br />
CTB [dB] -63 (3) -69 (4)<br />
XMOD [dB] -59 (3) -64 (4)<br />
CSO [dB] -64 (3) -70 (4)<br />
CIN [dB] - 60 (4)<br />
Manual level setup (2 dB steps) [dB] Plug-in 0-20<br />
Manual TILT setup (2 dB steps) [dB] Plug-in 0-22<br />
Breakpoint frequency of TILT [MHz] 302, 606, 750, 862, 1000<br />
ASG insertion loss (20°C) [dB] 6,5<br />
ASG control range [dB] ±4<br />
ASG flatness [dB] ±0,5<br />
Noise figure [dB] 7<br />
Testpoints' attenuation (inputs, outputs) [dB] -30±1<br />
Return loss (40 MHz -1,5 dB/octave) [dB] 18<br />
Return path gain [dB] 20<br />
CTB in return path [dB] -66 (2)<br />
CSO in return path [dB] -70 (2)<br />
Return path TILT (plug-in) [dB] 2, 4, 6, 8, 10<br />
Breakpoint frequency of TILT [MHz] 30, 65<br />
Specifications are subject to change without notice!<br />
19 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
Connecting impedance [Ω] 75<br />
Bridger output splitter, directional coupler [dB] Plug-in 4, 8, 12, 16<br />
Screening factor [dB] 80<br />
General parameters<br />
Maximum power consumption [W] 38<br />
Power supply voltage [V] 30-65; 35-90<br />
Class of electric shock protection<br />
III.<br />
Maximum current feed-through [A] 10<br />
Hum modulation [dB] 70<br />
Degree of protection IP 65<br />
Temperature range [°C] -40 … +60<br />
Type of connector 5/8”<br />
Dimensions [mm]<br />
275x172x122<br />
Weight [kg] 3,5<br />
(1) The value of gain and the diplex filters can be found in the typechart<br />
(2) Measured with 7 channels load in case of 110dBμV output level<br />
(3) 132 ch.flat, Vout:44dBmV<br />
(4) 79 ch. 7dB tilted, Vout:50dBmV @ 550MHz, 75digital ch. -6dB offset<br />
BLOCK DIAGRAM___________________________________________________________________<br />
SUPPLY<br />
60V AC<br />
AC FUSE<br />
SWITCHING POWER SUPPLY<br />
STATUS MONITORING SYSTEM<br />
SURGE<br />
PROT<br />
AC TP<br />
DC TP<br />
DC PWR<br />
SURGE<br />
PROT<br />
+ 24V DC<br />
BRIDGE<br />
OUT1<br />
EQ1<br />
AT1<br />
PRE AMP AT2 EQ2 BRIDG. AMP<br />
AC<br />
BYPASS<br />
BEQ<br />
AC<br />
BYPASS<br />
F1<br />
AC FUSE<br />
10 A<br />
AC FUSE<br />
10 A<br />
F4<br />
TP1<br />
-30dB<br />
TP4<br />
-30dB<br />
H<br />
L<br />
DF1<br />
ASG<br />
AT3 EQ3<br />
ASG ATT<br />
STAT. MON.<br />
INTERFACE<br />
BRIDG. AMP<br />
DF3<br />
H<br />
L<br />
DF2<br />
H<br />
L<br />
TP2<br />
-30dB<br />
TP3<br />
-30dB<br />
F2<br />
AC FUSE<br />
10 A<br />
AC FUSE<br />
10 A<br />
F3<br />
AC<br />
BYPASS<br />
30, 65 MHz<br />
RSW1<br />
SD<br />
SP or<br />
DC<br />
AC<br />
BYPASS<br />
EQ4<br />
AT3<br />
REV AMP<br />
RELPF<br />
RSW2<br />
BRIDGE<br />
OUT 3<br />
REV. INJ<br />
-20dB<br />
BRIDGE<br />
OUT 2<br />
SURGE<br />
PROT<br />
RF<br />
SURGE<br />
PROT<br />
Specifications are subject to change without notice!<br />
20 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
<strong>2010</strong><br />
<strong>New</strong> <strong>Products</strong><br />
ORDERING INFORMATION_____________________________________________________________<br />
M B 1 0 X X X - X X R X X<br />
Gain<br />
38 38dB gain<br />
42 42dB gain<br />
48 48dB gain<br />
Return path gain<br />
20 20 dB<br />
25 25 dB<br />
Type of the diplex filter<br />
30 Internal 30/47MHz diplex filter<br />
65 Internal 65/85MHz diplex filter<br />
Amplifier-module type<br />
C GaAs<br />
D GaN<br />
Options<br />
ASG option<br />
Monitoring option<br />
Required modules<br />
1pc ASG 535-C, 1pc BEQxxx-A, 1pc ATxx<br />
1pc NMT-F, 2pc RSW2-A<br />
Specifications are subject to change without notice!<br />
21 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
LE1000 SERIES LINE AMPLIFIERS<br />
• Outdoor aluminium casting case<br />
• Pull-out internal casting tray electronics<br />
• Internal diplex filters<br />
• Splittable high-leveled output<br />
• Internal return path hybrid module<br />
• 1GHz GaAs or GaN Power-doubler hybrids<br />
• Remote powered switching power supply<br />
• Pilot control option<br />
• Return path noise switch-off option<br />
• Status monitoring option<br />
TECHNICAL SPECIFICATIONS ___________________________________________________________<br />
RF parameters LE10xxC-xx LE10xxD-xx<br />
Amplifier-module GaAs PD hybrid GaN PD hybrid<br />
Forward path bandwidth [MHz] 47-1000 or 85-1000<br />
Return path bandwidth [MHz] 5-30 or 5-65<br />
Type of diplex filter [MHz] 30/47, 65/85 (1)<br />
Forward path gain [dB] 36 / 42 / 46 (1)<br />
Flatness [dB] ±0,75<br />
CTB [dB] -63 (3) -69 (4)<br />
XMOD [dB] -59 (3) -64 (4)<br />
CSO [dB] -64 (3) -70 (4)<br />
CIN [dB] - 60 (4)<br />
Manual level setup (2 dB steps) [dB] Plug-in 0-20<br />
Manual TILT setup (2 dB steps) [dB] Plug-in 0-22<br />
Breakpoint frequency of TILT [MHz] 302, 606, 750, 862, 1000<br />
ASG insertion loss (20°C) [dB] 6,5<br />
ASG control range [dB] ±4<br />
ASG flatness [dB] ±0,5<br />
Noise figure [dB] 7<br />
Testpoints' attenuation (inputs, outputs) [dB] -30±1<br />
Return loss (40 MHz -1,5 dB/octave) [dB] 18<br />
Return path gain [dB] 20 (3)<br />
CTB in return path [dB] -69 (2)<br />
CSO in return path [dB] -70 (2)<br />
Return path TILT [dB] Plug-in 2, 4, 6, 8, 10<br />
Breakpoint frequency of TILT [MHz] 30, 65<br />
Connecting impedance [Ω] 75<br />
Specifications are subject to change without notice!<br />
22 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
<strong>2010</strong><br />
<strong>New</strong> <strong>Products</strong><br />
Output splitter, directional coupler [dB] Plug-in 4, 8, 12, 16<br />
Screening factor [dB] 80<br />
General parameters<br />
Maximum power consumption [W] 25<br />
Power supply voltage [V] 30-65; 35-90<br />
Class of electric shock protection<br />
III.<br />
Maximum current feed-through [A] 10<br />
Hum modulation [dB] 70<br />
Degree of protection IP 65<br />
Temperature range [°C] -40 … +60<br />
Type of connector 5/8”<br />
Dimensions [mm]<br />
275x172x122<br />
Weight [kg] 3,5<br />
(1) The value of gain and the diplex filters can be found in the typechart<br />
(2) Measured with 7 channels load in case of 110dBμV output level<br />
(3) 132 ch.flat, Vout:44dBmV<br />
(4) 79 ch. 7dB tilted, Vout:50dBmV @ 550MHz, 75digital ch. -6dB offset<br />
BLOCK DIAGRAM___________________________________________________________________<br />
SUPPLY<br />
60V AC<br />
AC FUSE<br />
SWITCHING POWER SUPPLY<br />
STATUS MONITORING SYSTEM<br />
SURGE<br />
PROT<br />
AC TP<br />
DC TP<br />
DC PWR<br />
SURGE<br />
PROT<br />
IN<br />
+ 24V DC<br />
OUT 1<br />
EQ1<br />
AT1<br />
PRE AMP REQ BEQ EQ2<br />
POST AMP<br />
AC<br />
BYPASS<br />
AC<br />
BYPASS<br />
AC FUSE<br />
10 A<br />
TP1<br />
-30dB<br />
H<br />
L<br />
DF1<br />
ASG<br />
ASG ATT<br />
STAT. MON.<br />
INTERFACE<br />
H<br />
L<br />
DF2<br />
SP or<br />
DC<br />
SD<br />
TP2<br />
-30dB<br />
TP3<br />
-30dB<br />
AC FUSE<br />
10 A<br />
AC FUSE<br />
10 A<br />
30, 65 MHz<br />
AC<br />
BYPASS<br />
EQ3<br />
AT2<br />
REV AMP<br />
RELPF<br />
RSW<br />
REV. INJ<br />
-20dB<br />
OUT 2<br />
RF<br />
SURGE<br />
PROT<br />
Specifications are subject to change without notice!<br />
23 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
ORDERING INFORMATION_____________________________________________________________<br />
L E 1 0 X X X - X X R X X<br />
Gain<br />
36 Gain 36dB<br />
42 Gain 42dB<br />
46 Gain 46dB<br />
Return path gain<br />
20 20 dB<br />
25 25 dB<br />
Type of the diplex filter<br />
30 Internal 30/47MHz diplex filter<br />
65 Internal 65/85MHz diplex filter<br />
Amplifier-module type<br />
C GaAs<br />
D GaN<br />
Options<br />
ASG option<br />
Monitoring option<br />
Required modules<br />
1pc ASG 535-C, 1pc BEQxxx-A, 1pc ATxx<br />
1pc NMT-F, 1pc RSW2-A<br />
Specifications are subject to change without notice!<br />
24 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
<strong>2010</strong><br />
<strong>New</strong> <strong>Products</strong><br />
MONITORING PRODUCTS<br />
STANDARD HMS TRANSPONDERS (PRE-LIMINARY)<br />
• HMS 1.0<br />
• Remote software update<br />
• SNMP<br />
• To Comtech and other vendors' amplifiers and<br />
nodes<br />
GENERAL INFORMATION______________________________________________________________<br />
Comtech Ltd. started to develop and produce transponders 10 years ago. Present days around 15000<br />
transponders can be found in our customers systems (Tarr Kft., T-Kábel). These transponders' physical conditions<br />
(modulation, bit-rate) are in accordance with the HMS monitoring standard but the communication between<br />
transponder and HMTS is realized by a unique protocol (which enables a much faster data-communication than<br />
the HMS protocol). We have received a lot of demand for HMS compatibility, so at the end of the last year we<br />
started developing our HMS compatible transponder.<br />
The launch of the new transponder on the market is expected in june-july <strong>2010</strong>.<br />
ORDER INFORMATION_______________________________________________________________<br />
TRANSPONDERS TO <strong>COMTECH</strong> PRODUCTS:<br />
N M T H - F X X X MT800 series, MT1000 series, MB800<br />
series, MB1000 series, LE800 series,<br />
LE1000 series, MO802R, MO804R, MO1004<br />
N M T H - O X X X<br />
N M T H - C O M 1 - X X X MO801R<br />
MO803R, MO1003<br />
N M T H - C O M 2 - X X X MDO801x<br />
N M T H - C O M 3 - X X X LA8xxR-A, LA836R-C, DA836x-C<br />
N M T H - C O M 4 - X X X LA834R-H<br />
Specifications are subject to change without notice!<br />
25 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
TRANSPONDERS TO HARMONIC PRODUCTS:<br />
N M T H - H L W 1 - X X X HLR-3830, Antec LLRX200<br />
N M T H - H L W 2 - X X X HLN-3812<br />
N M T H - H L W 3 - X X X HLN-3822, HLN-3842, HLN-3844<br />
TRANSPONDERS TO KATHREIN PRODUCTS:<br />
N M T H - K A T 1 - X X X VGF amplifiers<br />
TRANSPONDERS TO MOTOROLA PRODUCTS:<br />
N M T H - M O T 1 - X X X MB-87, MB-100<br />
Frequency range<br />
85 85-88MHz<br />
108 106-114MHz<br />
Specifications are subject to change without notice!<br />
26 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
<strong>2010</strong><br />
<strong>New</strong> <strong>Products</strong><br />
NMT-COM4 MONITORING TRANSPONDER MODULE<br />
• Noise switch-off control<br />
• Monitoring of the amplifier's parameters<br />
• Monitoring of the signal and noise level in the<br />
CATV system<br />
• Remote software-update possibility<br />
• Infrared data read-out<br />
TECHNICAL SPECIFICATIONS ___________________________________________________________<br />
Monitoring parameters<br />
Monitored parameters<br />
Peak value of remote power, operation power, operation temperature, measured return path noise on 6MHz on<br />
outputs, transponder's receiver and transmitter level.<br />
Controlled parameters<br />
Monitored devices<br />
RF parameters<br />
State of the noise switch-off module (Off, On, -6dB, Auto).<br />
LA834R-H<br />
Transmitter output level range [dBµV] 80-120<br />
Receiver input level range [dBµV] 40-80<br />
Output level accuracy [dB] ±3<br />
Transmitter frequency [MHz] 18-28<br />
Receiver frequency [MHz] 85-88 or 106-114<br />
Transmitter and receiver frequency raster [kHz] 100<br />
Transmitter and receiver frequency accuracy [kHz] 10<br />
Isolation [dB] -60<br />
Output impedance [Ω] 75<br />
Modulation<br />
General parameters<br />
FSK±50kHz<br />
Baud rate [baud] 38400<br />
Power supply voltage [VDC] 12<br />
Power consumption [VA] 2,7<br />
Temperature range [°C]<br />
-40…+60<br />
Specifications are subject to change without notice!<br />
27 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
BLOCK DIAGRAM___________________________________________________________________<br />
DET<br />
C°<br />
RX<br />
MICRO<br />
CONTROLLER<br />
TX<br />
INFRA<br />
POWER<br />
SUPPLY<br />
0 dB<br />
-6 dB<br />
-60 dB<br />
OUT IN<br />
Return Path<br />
AC60V<br />
DC24V<br />
RF OUT RF IN<br />
ORDERING INFORMATION_____________________________________________________________<br />
N M T - C O M 4 - X X X<br />
Receiving frequency range<br />
85 85-88MHz<br />
108 106-114MHz<br />
Specifications are subject to change without notice!<br />
28 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
<strong>2010</strong><br />
<strong>New</strong> <strong>Products</strong><br />
RBS622Q-C RETURN PATH AMPLIFIER MODULE WITH MONITORING OPTION<br />
• High output level<br />
• Plug-in construction<br />
• Flat frequency response<br />
• Excellent return loss parameters<br />
• Built-in noise switch-off<br />
• Noise monitoring<br />
• Monitoring option for LA834R-H amplifiers<br />
TECHNICAL SPECIFICATIONS ___________________________________________________________<br />
Frequency range [MHz] 5-65<br />
Gain (at On state) [dB] 22<br />
Gain (at -6dB state) [dB] 16<br />
Attenuation (at Off state) [dB] > 60<br />
Maximum output level (IMA-III. B-60 dB) [dBµV] 116<br />
Maximum output level (IMA-II. B-60 dB) [dBµV] 119<br />
Return loss [dB] > 18<br />
Return loss (Off state) [dB] > 22<br />
Monitored noise bandwith [MHz] 5,9-6,1<br />
Supply voltage [V] 12<br />
Current consumption (at On state)[mA] 180<br />
Current consumption (at Off state)[mA] 50<br />
Temperature range [°C] -40 … +60<br />
BLOCK DIAGRAM___________________________________________________________________<br />
-60dB<br />
RBS622Q-C<br />
0 dB<br />
-6 dB<br />
Controller (0dB; -6dB; -60dB))<br />
REV-IN DETECTED<br />
NOISE LEVEL<br />
INDICATOR<br />
(6 MHz)<br />
CONTROLLING<br />
+12V<br />
REV-OUT<br />
ORDERING INFORMATION_____________________________________________________________<br />
R B S 6 2 2 Q - C<br />
Specifications are subject to change without notice!<br />
29 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
NMT-HLW3 MONITORING TRANSPONDER MODULE FOR HARMONIC OPTICAL NODES<br />
• Noise switch-off control<br />
• Monitoring of the node's parameters<br />
• Monitoring of the signal and noise level in the<br />
CATV system<br />
• Remote software-update possibility<br />
• Infrared data read-out<br />
• Supported optical nodes: HLN-3822, HLN-384x<br />
TECHNICAL SPECIFICATIONS ___________________________________________________________<br />
Monitoring parameters<br />
Optical node's monitored parameters<br />
Peak value of remote power, operation power supplies (12V, 24V), operation temperature, measured return path<br />
noise on 6MHz on outputs, transponder's receiver and transmitter level, receiver's and transmitter's power, laser<br />
current.<br />
Controlled parameters<br />
Monitored device<br />
RF parameters<br />
Transmitter output level range [dBµV] 80-110<br />
Receiver input level range [dBµV] 40-80<br />
Output level accuracy [dB] ±3<br />
Transmitter frequency [MHz] 18-28<br />
State of the noise switch-off module (Off, On, -6dB, Auto).<br />
HLN-3822,HLN-384x<br />
Receiver frequency [MHz] 85-88 or 106-114<br />
Transmitter and receiver frequency raster [kHz] 100<br />
Transmitter and receiver frequency accuracy [kHz] ±10<br />
Isolation [dB] -60<br />
Output impedance [Ω] 75<br />
Modulation<br />
General parameters<br />
FSK±50kHz<br />
Baud rate [baud] 38400<br />
Power supply voltage [VDC] +12<br />
Power consumption [VA] 2,7<br />
Temperature range [°C]<br />
-40…+60<br />
Specifications are subject to change without notice!<br />
30 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
<strong>2010</strong><br />
<strong>New</strong> <strong>Products</strong><br />
BLOCK DIAGRAM___________________________________________________________________<br />
C°<br />
INFRA<br />
RX<br />
MICRO<br />
CONTROLLER<br />
TX<br />
POWER<br />
SUPPLY<br />
0 dB<br />
-6 dB<br />
-50 dB<br />
0 dB<br />
-6 dB<br />
-50 dB<br />
OUT1<br />
Return Path<br />
OUT2<br />
Return Path<br />
OPT TX<br />
DC24V<br />
DC12V<br />
RF OUT RF IN<br />
OPT RX<br />
ORDERING INFORMATION_____________________________________________________________<br />
N M T - H L W 3 - X X X<br />
Receiving frequency range<br />
85 85-88MHz<br />
108 106-114MHz<br />
Option<br />
Required modules<br />
Ordering<br />
information<br />
Noise switch-off option HLN-3822 1pc RSW-H3 return path noise switch-off module RSW-H3<br />
Noise switch-off option HLN-384x 1pc RSW-H4 return path noise switch-off module RSW-H4<br />
Specifications are subject to change without notice!<br />
31 PG-<strong>2010</strong>-05-EN
<strong>New</strong> <strong>Products</strong> May, <strong>2010</strong><br />
RSW-H4 RETURN PATH SWITCH MODULE INTO HARMONIC HLN-384X OPTICAL NODE<br />
• Controlled by the NMT-HLW3 module<br />
• Plug-in construction<br />
• High suppression loss<br />
• Low insertion loss<br />
• Three switching states<br />
• State-indication by LED's<br />
TECHNICAL SPECIFICATIONS ___________________________________________________________<br />
Frequency range [MHz] 5-65<br />
Insertion loss (at On state) [dB] 0,6 ± 0,2<br />
Insertion loss (at -6dB state) [dB] -7 ± 0,5<br />
Insertion loss (at Off state) [dB]<br />
(5-30 MHz)<br />
(30-65 MHz)<br />
> 50<br />
> 40<br />
Maximum output level (IMA III. B-60 dB) [dBµV] 117<br />
Maximum output level (IMA II. B-60 dB) [dBµV] 116<br />
Return loss (at Off state) [dB] > 20<br />
Return loss (at On state) [dB] > 20<br />
Temperature range [°C]<br />
Power supply voltage [V] +5<br />
Current consumption (at Off state) [mA] 20<br />
Current consumption (at On state) [mA] 30<br />
Control voltage switch Off [VDC] 5<br />
Control voltage switch On [VDC] 0<br />
-40…+60<br />
BLOCK DIAGRAM___________________________________________________________________<br />
OUT1 OUT2<br />
-50dB -50dB<br />
OUT1 OUT2<br />
-50dB -50dB<br />
RSW-H4<br />
RSW-H4<br />
IN1<br />
0 dB<br />
-6 dB<br />
-50 dB<br />
IN1<br />
0 dB<br />
-6 dB<br />
-50 dB<br />
CONTROLLER<br />
CONTROLLER<br />
MUX<br />
DET<br />
MUX<br />
DET<br />
IN2<br />
0 dB<br />
-6 dB<br />
-50 dB<br />
IN2<br />
0 dB<br />
-6 dB<br />
-50 dB<br />
+24V<br />
CONTROLLING<br />
+24V<br />
CONTROLLING<br />
NMT-HLW3<br />
ORDERING INFORMATION_____________________________________________________________<br />
R S W - H 4 Return path switch module into HLN-384x optical node<br />
Specifications are subject to change without notice!<br />
32 PG-<strong>2010</strong>-05-EN
<strong>2010</strong><br />
<strong>New</strong> <strong>Products</strong>
Distributors, partners:<br />
Schaffelhofer CATV-Service<br />
Kalchgruberweg 9<br />
4210 Unterweitersdorf<br />
Austria<br />
Tel.: +43 7235 649211<br />
Fax: +43 7235 649214<br />
E-mail: catv@schaffelhofer.tv<br />
Normann Engineering GmbH<br />
Linzer str. 139<br />
A-4600 Wels<br />
Austria<br />
Tel.: +43 7242 70 921-0<br />
Fax: +43 7242 70 921-20<br />
E-mail: office@normann.at<br />
(Only monitoring system)<br />
<strong>KABELKON</strong>, The Authorized Channel Partner<br />
Cart. Florilor 41/E<br />
535500 GheorgheniRomania<br />
Romania<br />
Tel.: +40266364525<br />
Fax: +40266364080<br />
E-mail : kabelkon@kabelkon.ro<br />
EuroMedia-Service GmbH<br />
Willi-Bleicher strasse 35<br />
52353 Düren<br />
Germany<br />
Tel.: +49 2421 6936051<br />
Fax: +49 2421 6932179<br />
E-mail: christoph.tiede@euromedia-service.de<br />
(Only monitoring system)<br />
SmartCable Technology BV<br />
Hoogstad 259<br />
3131 KX Vlaardingen<br />
The Netherlands<br />
Tel.: +31 10 248 0630<br />
Fax: +31 10 248 0631<br />
E-mail: smartcable@smartcable.nl<br />
XD VISION, s.r.o.<br />
Vyšehradská 8<br />
85106 Bratislava<br />
Slovakia<br />
Tel.: +421 25363 1314,5<br />
Fax: +421 25363 1316<br />
E-mail: satba@xdvision.sk<br />
JJJ SAT & BESIE s.r.o.<br />
Strešovická 35<br />
Praha 6, 16200<br />
Czech Republic<br />
Tel.: +420 233 090 050<br />
Fax: +420 233 090 055<br />
E-mail: sales@jjjsat.cz<br />
IPMEDIA International GmbH<br />
Hermannstrasse 19<br />
31180 Giesen<br />
Germany<br />
Tel.:+49 (0) 5066 90 21 24<br />
Fax:+49 (0) 5066 90 21 25<br />
E-mail: info@ipmint.de<br />
TELETRONIC PLUS SRL<br />
Arad, Str. Roman Ciorogariu, Nr.33<br />
Judetul Arad<br />
Romania<br />
Tel.: +40 743137106<br />
Tel./Fax: +40 3574 07 080<br />
E-mail: teletronicplus@yahoo.com<br />
<strong>COMTECH</strong> Communication-technology Ltd.<br />
H-9028 GYÕR, Török Ignác u. 66.<br />
Tel.: +36 (96) 412 299<br />
Fax:+36 (96) 511 200<br />
E-mail: sales@comtech.co.hu,<br />
mail@comtech.co.hu