2 - 16 Needle Clearance to Shuttle<br />

SECTION 2 - 16<br />

PAGE 1<br />

* * Before checking, follow Section 2 - 2 Needle Position at Straight and Maximum<br />

Zigzag Width and 2 - 14 Needle Height.<br />

Checking:<br />

1. Remove bobbin case and shuttle race cover.<br />

2. Set machine at "zigzag stitching C, (maximum width)" by turning selector dial.<br />

3. Turning hand wheel, bring up needle from its right hand lowest point until<br />

shuttle hook point comes to align with left side of needle. Check if clearance<br />

(A) between hook point and upper edge of needle eye is about 1.0 mm.<br />

Adjustment:<br />

1. Loosen bolt (2) of lower shaft arm (1).<br />

2. Rotate shuttle with finger until hook point comes to align with the left side of<br />

needle.<br />

3. Holding shuttle at this position, slowly bring up needle until the correct vertical<br />

clearance is attained between shuttle hook point and upper edge of<br />

needle eye.<br />

4. Tighten screw (2) securely after adjustment, keeping the angle of the shuttle<br />

as adjusted.<br />