SECTION 2 - 15<br />

PAGE 3<br />

B - Needle touches back of needle hole (Fig. b - PAGE 2).<br />

1 Loosen screws (11), (12) of setting plate (10) for lower shaft bush.<br />

However, lower shaft bush (13) must not float. (Big clearance should<br />

not be made between setting plate and bush.)<br />

2 Moving lower shaft gear assy (14) to left (C). Lower shaft gear (8)<br />

must always engage with shuttle shaft gear.<br />

3 Loosen screws (4), (5).<br />

4 Adjust needle clearance to shuttle by moving shuttle race assy to<br />

wards you (B direction - PAGE 2) and tighten screws (4), (5).<br />

5 Move lower shaft gear assy (14) along shaft and adjust backlash be<br />

tween lower shaft gear (8) and shuttle shaft gear (9).<br />

6 Tighten screws (11), (12).<br />

※ Check following "Checking rotating direction of shuttle race assy" (next<br />

page) and "2 - 15 Needle timing to shuttle" after adjustment.