2 - 8 Feed Dog Timing<br />

SECTION 2 - 8<br />

PAGE 1<br />

Vertical Movement<br />

* * Before checking, follow Section 2 - 5 Feed Dog Height.<br />

Checking:<br />

1. Set machine for maximum stitch length.<br />

2. Turning hand wheel, move down feed dog.<br />

3. Check if vertical clearance (P) between needle point and needle plate surface<br />

is within the range of 4 - 6 mm when top of feed dog reaches needle<br />

plate surface level.<br />

Adjustment:<br />

1. Remove base cover.<br />

2. Loosen screw (2) of feed lifting cam (1).<br />

3. Adjust feed dog timing to needle by slightly rotating feed lifting cam (1) in<br />

either direction as shown.<br />

To retard timing ð Turn the cam to A - direction.<br />

To advance timing ð Turn the cam to B - direction.<br />

4. Tighten screw (2) after adjustment.