Maintenance Instructions<br />

1.2 RECOMMENDED CONTROL ROUTINES<br />

• Check all central units and field units for damage or other irregularities that can cause<br />

damage to the system.<br />

• Operation control.<br />

This control must be carried out on all access units.<br />

Use the microphone and check that access is possible from all the access units.<br />

The Operating instruction doc no. 96106-000-OI can be used as a guide during the test.<br />

Check that audio is clear and that the loudspeaker coverage is OK.<br />

Verify that muting is OK for each access unit local loudspeaker when PA message.<br />

Check access in correct zones.<br />

• Override outputs<br />

Check that override function is OK on all volume control units.<br />

Write down every irregularity in the log book.<br />

1.3 FAULT FINDING<br />

1.3.1 Fuses<br />

Replace a blown fuse with a new one of the same value. If the second fuse blows, locate and<br />

correct the fault.<br />

Make sure that you always have a good supply of fuses.<br />

1.3.2 Contacts<br />

A high percentage of failures are caused by faulty cable connections, plugs, sockets etc.<br />

Such details are checked very carefully during installation, but it is difficult to guard fully<br />

against vibration, corrosion and dust.<br />

You are therefore advised to make an occasional thorough check on all plugs, sockets, terminal<br />

boards, switches and relays.<br />

1.3.3 Equipment/loudspeakers<br />

Keep all equipment clean - outside and inside. Keeping the main switch off, remove cover plates<br />

and clean all parts carefully - using a soft brush. Be careful not to damage components. Keep all<br />

ground connections tight and clean.<br />