Handbook page<br />

27/94<br />

COMMISSIONING PROCEDURE<br />

FOR<br />

<strong>SPA</strong>-1500 SYSTEM<br />

Doc.No.: 96106-000-CP<br />

1. CHECK THAT CABLING IS ACCORDING TO APPROVED DRAWINGS.<br />

2. USE <strong>SPA</strong>-1501 AND 1593 UNIT TO ACCESS ZONE 1 TO 3 AND VERIFY AUDIO IN<br />

THE CORRESPONDING SPEAKERS. ALSO VERIFY 24VDC VOLUME<br />

OVERRIDE OUTPUT FOR ZONE 1-3(TERM.15/16,17/18,33/34) IF IN USE.<br />

3. ACTIVATE ENTERTAINMENT IF INSTALLED AND VERIFY THAT IT’S<br />

DISTRIBUTED TO THE SELECTED ZONE.(SWITCHES IN FRONT)<br />

4. IF AN ALARMCARD IS INSTALLED TEST THAT BOTH ALARMS IS<br />

DISTRIBUTED TO ALL ZONES AND CAN BE OVERRIDED BY THE<br />

ACCESS PANEL(S) 1501 AND 1593. (USER1 TO USER 3 AND EXTERNAL INPUT)<br />

CHECH PRIORITY AS FOLLOW:<br />

• PRIO 1 = USER 1 (1501 OR 1593)<br />

• PRIO 2 = USER 2<br />

• PRIO 3 = USER 3<br />

5. IF AN ALARMCARD OR DING-DONG CARD IS INSTALLED EACH<br />

ANNOUNCEMENT COULD START WITH A PRETONE.<br />

6. IF THE EXTERNAL INPUT IS IN USE, THEN CHECK THAT THE AUDIO<br />

IS DISTRIBUTED TO THE PRESELECTED ZONES(DIPSWITCH S7 1-3)<br />

7. IF EXTERNAL OUTPUT(AUDIO/KEY) IS IN USE, VERIFY AUDIO IS<br />

PRESENT AT TERMINALS 100/101 REGARDLESS OF THE ZONE SELECTIONS.<br />

KEY 1 AND 2 OUTPUT IS POTENSIAL FREE RELAY CONTACTS.<br />

02 19.08.2009 REVISION, EM 1209 CD TBA CD<br />

01 11.10.2006 CUSTOM REQUIRE TBA PA AHJ<br />

0 05.02.02 CUSTOM REQUIRE AHJ TEH AHJ<br />

Page 1 of 2<br />

V:\prosjekt\96106 <strong>SPA</strong>-1500\DOC\96106-000-CP Commissioning procedure.doc<br />

This document is the property of PHONTECH and must<br />

not be copied or shown to a third person without our<br />

written acceptance. In the interest of product<br />

improvement, PHONTECH reserves the right to alter<br />

specification and design without notice.<br />

REV No: ISSUE DATE REASON FOR ISSUE PREPARED CHECKED APPROVED<br />

TITLE: <strong>SPA</strong> 1500 system<br />

COMMISSIONING PROCEDURE SIZE: A4 UED no:<br />

DOC no: 96106-000-CP<br />

FILE NAME:<br />

96106-000-CP<br />

Commissioning procedure.doc

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!