Handbook page<br />

21/94<br />

<strong>SPA</strong> 1500<br />

Installation instructions<br />

For identification each cable shall be marked with cable tag number clearly visible inside<br />

cabinets. For smaller units the cable identification shall be located outside the unit (outside the<br />

cable glands).<br />

When the number of cables makes it difficult to locate each cable, the first pair in the cable<br />

shall be marked with the cable tag number.<br />

The armour shall be tied back, covered with a yellow/green sleeve and terminated on the<br />

Protective Earth Bar (PE).<br />

The screen shall be covered with a transparent sleeve and terminated on the Telecom Earth Bar<br />

or isolated based on criteria as below:<br />

• For interconnection between a main equipment cabinet and a Field Termination Cabinet<br />

(FTC) or main Distribution Frame (MDF) the screen shall be terminated in the FTC/MDF<br />

and isolated in the main cabinet.<br />

• For interconnection between main equipment cabinets the screen shall be terminated in one<br />

end only. Preference shall be given to the main equipment cabinet seen as the origin of the<br />

cable.<br />

• For interconnection between Field and Central Equipment the screen shall be terminated in<br />

the Central equipment and isolated in the Field Equipment.<br />

The cable cores shall have sufficient length to reach all terminals in the terminal block.<br />

Wires shall be terminated using a crimped lug or ferrule. The lug shall be applied using<br />

appropriate tools for the application.<br />

All cores shall be terminated.<br />

Individual cores shall be identified with a closed slip-on type of plastic identification ferrule<br />

carrying a number identical to the terminal (not valid for “plug type” connections).<br />

For terminal blocks of IDC type or similar (Krone, Wago, Bix blocks, etc.) the correct tool<br />

shall be used for core insertion. Knives, screw drivers, etc. shall not be used.<br />

For twisted pair type of cable the cores shall be kept revolved as close as possible to the<br />

terminal.<br />

The correct tool for the application shall always be used.<br />

Testing<br />

Testing of Special Cables shall be performed at the end of installation or in the mechanical<br />

completion/pre-commissioning phase.<br />

96106-000-IN Installation instructions.doc<br />

Page 6 of 9