Installation instructions<br />

7 INSTALLATION OF EQUIPMENT<br />

7.1 Central Equipment<br />

All central cabinets shall be installed in accordance with applicable Layout Drawings and<br />

Equipment Arrangement Drawings.<br />

• Care shall be taken while installing the equipment not to cause any unnecessary damage<br />

due to unfamiliarity of the equipment.<br />

7.2 Installation of Field Equipment<br />

General<br />

All field equipment, such as Loudspeakers, Beacons, Access Panels etc. shall be installed in<br />

accordance with applicable Data sheets, Layout Drawings and Equipment Arrangement<br />

Drawings. A document revision check shall be carried out to ensure that the work packages<br />

contain the latest issue of the drawings/documents.<br />

Any equipment installed outdoors and left in a turned off condition must be properly weather<br />

proofed as per manufacturers manuals. Weather proofing shall ensure that no excess humidity<br />

or water enters the equipment causing corrosion.<br />

General Location Rules<br />

Equipment should be located in accordance with the following requirements:<br />

• Protected against damage.<br />

• Protected against vibration.<br />

• Operability and serviceability.<br />

• Display instruments and flashing lights to be legible and visible from main access areas.<br />

• Accessibility for maintenance without scaffolding.<br />

Electrical equipment should not be located in open deck areas.<br />

Equipment, which has to be installed in exposed areas, should be sheltered by use of<br />

enclosures.<br />

When Junction Boxes are installed in exposed areas, drain plugs shall be installed.<br />

Final location shall be selected to avoid interference with escape routings, walkways, other<br />

equipment, pipes, etc. and obstruction against activities related to transport and lifting<br />

operations.<br />

Heavy equipment should not be supported on pipe work, handrails, access ladders or cable<br />

ladders.<br />

Equipment located in areas which do not allow for maintenance accessibility as required,<br />

should be installed on brackets which are arranged such that the equipment can be rotated,<br />

raised or lowered into areas where maintenance can take place without the need for scaffolding.<br />

Junction Boxes<br />

Local Junction Boxes should be installed directly on steel supports adjacent to the equipment.<br />

The junction boxes shall be installed so that they are easily accessible.<br />

Area Junction Boxes shall be installed in accordance with the functional requirements<br />

discussed above.<br />

Access Panels<br />

Access Panels, which are not installed in consoles/cabinets/racks/etc. but are to be field<br />

mounted, shall be located approximately 1.5 m above deck/floor.<br />

96106-000-IN Installation instructions.doc<br />

Page 4 of 9