Handook page<br />
50/128<br />
Installation Guide<br />
PBX Interface T942PX<br />
TD 91012GB<br />
PBX Interface T942PX - Installation Guide<br />
T942PX is an interface unit between the teleCOURIER <strong>900</strong> paging system and a telephone exchange,<br />
PBX (Private Branch Exchange). In some cases the T942PX is used to connect a telephone as control<br />
instrument. The PX unit may be connected to an extension or to a trunk line. When connected to a<br />
trunk line it detects and generates both dial pulses and DTMF tone signals. When connected to an<br />
extension it detects and generates DTMF tone signals and generates dial pulses.<br />
E & M signaling according to ”ESPA standard interface recommendation 4.4.3” is also possible. If<br />
speech is used in the system, speech module T941SM is included.<br />
A FLASH PROM in T942PX enables remote programming of the program and parameters.<br />
Note: T942PX is not intended for connection to public telephone networks.<br />
1. General<br />
Supply voltage: 12,5 Vdc ± 10%<br />
Current consumption: Max 0,5 A<br />
Delivery includes:<br />
• T942PX<br />
• Modular bus cabling<br />
• If the T942PX is to be used in a speech installation,<br />
speech module T941SM is mounted on the<br />
T942PX PC board and installation guide<br />
TD 90648GB is included in the delivery.<br />
56,5<br />
Dimensions (H x W x D)<br />
275 x 130 x 60 mm<br />
112<br />
It is possible to order from your dealer package<br />
T942PX-2 art. no 541175. In addition to the above<br />
the delivery includes the following items:<br />
• Power supply Mascot 8311, 42 Vac<br />
• Telephone wall socket<br />
• Telephone (Respons)<br />
188,5<br />
9 9<br />
275<br />
Tools etc. required:<br />
• 2 mm drill<br />
• Screwdriver<br />
• Cutting pliers<br />
• Screws for installation<br />
• Multimeter<br />
• (Oscilloscope)<br />
65<br />
130<br />
Note:<br />
To facilitate service after the unit is installed,<br />
we recommend a free space of about 50 mm<br />
above and 150 mm below the unit.<br />
2<br />
2. Installation<br />
T942PX should be placed in a dry environment with<br />
a temperature of 0 to +40ºC. The unit can be<br />
connected together with other units in the<br />
teleCOURIER <strong>900</strong> system, either via modular bus<br />
cabling or via twisted-pairs (see points 8, 9, and 10).<br />
To replace the PC board, see point 18.<br />
The second drawing at left shows dimensions for<br />
installing the T942PX.<br />
1<br />
1<br />
Use a screwdriver or similar to release the cover by<br />
applying a light pressure to the two snap-catches (1)<br />
and remove the cover (2).<br />
1996 11 06 1