Installation Guide<br />
T942C- and T942C/2 Central Unit<br />
TD 91684GB<br />
Handook page<br />
13/128<br />
1.3.7 Connection of Code and Absent Indication from Common Line Charging Rack<br />
Connect absent indication from charging rack in system 5000 to T942C connector J11<br />
screw 4 and 5.<br />
T942C<br />
+6V<br />
S05<br />
J12<br />
3 OUT2 (CODE2)<br />
2 OUT1 (CODE1)<br />
1 +12V EXT OUT<br />
(CODE+)<br />
J11<br />
5 IN4 (ABS)<br />
4 IN3 (ABS+)<br />
1 +12V EXT IN<br />
to Common Line<br />
Charging Rack<br />
Figure 12. Connection of code and absent indication.<br />
Note: The digital inputs must be provided with supply voltage, see 1.3.9 Connection of<br />
Supply Voltage on page 13.<br />
1.3.8 Connection of Buses<br />
Buses are connected either via modular bus cabling or twisted-pairs.<br />
Note: The data buses are polarized. Use only twisted-pairs for two-wire connections!<br />
Bus connection via Modular Bus Cabling<br />
See figure 13 on page 12 for information about modular bus connectors.<br />
1 Connect modular bus cabling to J01 and J02.<br />
2 Connect additional modular bus cabling.<br />
For Common Line System:<br />
• connect J07<br />
For CTS System:<br />
• J07:connect to a C940LX<br />
• J08:connect only the ER and E-buses to a C940LX via a quick-connect terminal block<br />
(type Krone)<br />
2003-01-08 / Rev.C<br />
11