5 OPERATING INSTRUCTIONS<br />

5.1 FBR-3 FLOAT FREE BRACKET<br />

When the capsule is mounted in the FBR-3 bracket release mechanism, it operates<br />

as a float free automatic unit.<br />

5.2 MANUAL OPERATION OF EPIRB MODULE<br />

Figure 5.2, EPIRB Main switch<br />

The manual operation can be done when the capsule is mounted in the bracket<br />

or when the capsule is removed from the bracket.<br />

Break the seal on the main switch and pull the locking pin. Push in the leftmost<br />

part of switch mechanism and the switch will automatically go to the ON (Emergency)<br />

position.<br />

The red indicator lamp and the Xenon flash on the main board will start operating,<br />

indicating that the EPIRB module is active.<br />

NOTE!<br />

The EPIRB module performs a complete self-test before any emergency signals<br />

are transmitted. The Transmitters will start after approx. 70 seconds. At the<br />

same time GPS receiver is started. This is done to prevent the GPS receiver to<br />

start in TEST position. Turning the switch back to the READY position stops the<br />

transmission. If the Capsule is out of the bracket, make sure the battery compartment<br />

is dry to prevent activation of the seawater contacts.<br />