Catalog 2007/2008


Pipetman® Neo is an evolution of the classic<br />

Pipetman P that addresses the growing susceptibility<br />

of pipette users to repetitive strain injuries.<br />

Microman® positive displacement pipette is now<br />

available with a calibration certificate issued by the<br />

Gilson ISO 17025 accredited laboratory.<br />

The Gilson ISO 17025 accredited laboratory in France<br />

provides the undisputable guarantee and confidence<br />

that our Quality System and Standard Operating<br />

Procedures have been thoroughly evaluated and<br />

approved by a legitimate third party.<br />

Gilson Safe Aspiration Station® is a stand-alone<br />

vacuum system that incorporates all the essential<br />

characteristics to aspirate quickly and safely all kinds<br />

of liquids and collect them in a safe container.<br />

GmCLab is a compact and highly dependable<br />

personal mini-centrifuge that quickly separates<br />

particles from the supernatant in a solid-liquid<br />

mixture or spin down liquids to the bottom<br />

of a tube.<br />

ISO9001<br />

Certified<br />

Gilson Reagent Reservoirs are ideal for<br />

dispensing reagent with multichannel pipettes.<br />

Two different types of reservoirs are available,<br />

25 mL and 50 mL, standard or sterilized.<br />

Minipuls Evolution® laboratory peristaltic pump<br />

is the newest innovation from the makers<br />

of the Minipuls3, offering unmatched<br />

flexibility and performance for liquid<br />

transfer applications.<br />

ISO17025<br />

Accredited


MOTORIZED ELECTRONIC PIPETTES<br />

PIPETMAN Concept ® (single and multichannel) 4-7<br />

Gilson<br />

Application notes<br />

The Gilson application notes<br />

collection is included in this new<br />

catalog edition for the first time,<br />

spanning the world of pipetting<br />

and providing pipette users with<br />

keys to a better understanding of<br />

even the most mundane aspects<br />

of pipetting.<br />

See the application notes insert<br />

ADJUSTABLE AND FIXED VOLUME PIPETTES<br />

PIPETMAN ® Ultra (single and multichannel) 8-11<br />

PIPETMAN ® P 12-13<br />

PIPETMAN ® Neo 14-15<br />

PIPETMAN ® F 16<br />

PIPETTE KITS<br />

PIPETMAN ® Ultra Starter Kit 17<br />

PIPETMAN ® Micro-Volume Kit 17<br />

PIPETMAN ® Starter Kit 17<br />

PIPETMAN ® Large-Volume Kit 17<br />

ISO 17025 and Gilson pipettes 18-19<br />

PIPETTE ACCESSORIES<br />

Carrousel TM 20<br />

Gilson Reagent Reservoirs 20<br />

Name Tags 20<br />

Single TM Pipette Holder 20<br />

Trio TM Pipette Stand 20<br />

Coloris TM Identification Clips 20<br />

Pipetman Concept® Rapid-Charge Stand 20<br />

MOTORIZED PIPETTING AIDS<br />

Gilson Pipetting Aid 21<br />

Total commitment to our customers’<br />

satisfaction<br />

In accordance with the ISO 9001:2000, our company’s organization<br />

is based on processes addressing customers’ needs.<br />

High quality of conception and<br />

calibration of our products<br />

Our pipettes are designed, manufactured and calibrated in compliance<br />

with the specifications and methods of the ISO 8655 standard.<br />

Guarantee of our pipettes’ safety<br />

for In Vitro Diagnostics<br />

All our pipettes comply with the IVD Directive (98/79/EC) for In Vitro<br />

Diagnostics Medical Devices.<br />

High technical and metrological<br />

performances of our calibration<br />

laboratory<br />

Our independent pipette calibration laboratory is<br />

accredited by a national accreditation organization:<br />

- For its ability to calibrate pipettes in accordance with the ISO 8655.<br />

- For its capacity to reproduce reliable results.<br />

- For the reliability of its quality system.<br />

PIPETTE TIPS<br />

Diamond ® Tips: 22-27<br />

Standard tips, Filter tips, Sterilized tips<br />

Packaging: Tipack TM , Tower Pack TM , SterilPack TM ,<br />

EcoPack TM , EasyPack TM , Empty Racks<br />

POSITIVE DISPLACEMENT PIPETTES<br />

MICROMAN ® and Capillary Pistons 28-29<br />

MANUAL AND ELECTRONIC REPEATER PIPETTES<br />

DISTRIMAN ® and DistriTips ® 30<br />

REPETMAN ® and Repet-Tips 31<br />

PIPETTE REPLACEMENT PARTS 32-34<br />

ELECTRONIC MULTI-FUNCTION DILUTOR DISPENSERS<br />

402 DILUTOR - DISPENSER 35<br />

BENCH-TOP SOLUTIONS<br />

MINIPULS Evolution® 36-37<br />

MINIPULS TM 3 Peristaltic Pump 38<br />

MINIPULS Applications 39<br />

MINIPULS Accessories 40<br />

Gilson Safe Aspiration Station 41<br />

GmCLab mini centrifuge 42<br />

LabStir magnetic stirrer 43<br />

GVLab vortex mixer 43<br />

SERVICE<br />

Gilson Service network of trained distributors 44<br />

Gilson Preventive Maintenance 44<br />

On-Site Service 45<br />

The “Center of Excellence” Label 45<br />

Gilson training 46<br />

Pipetman® P Service Pack 46<br />

Do-it-yourself Performance Check: Weighing Kit 46<br />

CHEMICAL COMPATIBILITY TABLE 47


PIPETMAN Concept ®<br />

Simply a Click Away From Perfection<br />

The new Pipetman Concept motorized<br />

electronic pipette is even more finely<br />

tuned to your needs, a combination of<br />

tangible quality with high usability and<br />

comfort. Conceived with simplicity<br />

and flexibility in mind, it features<br />

exclusive multifunction<br />

characteristics housed in a<br />

traditional Gilson quality design.<br />

Twelve models cover the full range of<br />

volumes from 0.5 μL to 10 mL with<br />

single and multichannel pipettes for<br />

higher productivity and greater comfort.<br />

Multifunction Concept<br />

Unique PC connections via USB<br />

interface<br />

Create your own pipetting modes<br />

with the PC based Utility Software<br />

that lets you create and store any<br />

number of modes on your PC and<br />

transfer them to your pipette (PC<br />

connection kit, Ref. F30755). Modes are<br />

easily created from pre-programmed<br />

tasks and can be exchanged on the<br />

Internet within a community of users.<br />

Five standard pipetting modes cover<br />

more than 95% of current<br />

application modes: Automatic<br />

pipetting, Automatic pipetting<br />

+ Mixing, <strong>Manual</strong>,<br />

Repetitive, Reverse<br />

pipetting.<br />

<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


Amazingly comfortable<br />

operation<br />

Real ergonomic design of handle and<br />

keyboard addresses the users’ concern for<br />

Repetitive Strain Injuries, backed up by<br />

extensive end-user trials.<br />

Adjustable tip-ejector<br />

button<br />

GLP Concept, make<br />

no compromise on quality<br />

• ISO 8655 and CE / IVD (98/79/EC) compliant.<br />

• Keypad disabled during pipetting.<br />

• The Utility Software allows locking of the system<br />

menu from your PC.<br />

• Pipette status always on screen.<br />

• Color coding to identify the model and corresponding<br />

Diamond® tip range.<br />

• Color-coded ID Tags to write your name or application.<br />

• User-defined stand-by screen text.<br />

For more details, see the application notes insert<br />

Adjustable tip-ejector<br />

stroke<br />

Adjustable<br />

hook<br />

Exclusive G-F.I.T. System TM .<br />

The exclusive Gilson Forceless Integrated Tip-ejection<br />

System provides instant reliable seals and low ejection<br />

forces for Large Volume (C5000, C10mL) and Multichannel<br />

models. G-F.I.T. System is compatible with most standard tips.<br />

Systematic error (µL)<br />

Calibration is easy and adaptable<br />

to your needs<br />

Exceeds ISO 8655 Specifications. Pipetman Concept’s<br />

specifications are more stringent than those required to be<br />

ISO 8655 compliant.<br />

4<br />

3<br />

2<br />

1<br />

0<br />

-1<br />

-2<br />

PIPETMANConcept C300 specifications<br />

ISO 8655<br />

Learn more about<br />

Gilson’s exclusive<br />

G-F.I.T. System on page 9<br />

G -F.I.T. S yste m<br />

-3<br />

-4<br />

0 50 100 150 200 250 300<br />

Volume (µL)<br />

10%<br />

50% 100%<br />

Powerful and easy user’s adjustment.<br />

Readjustment is performed at the 3 points of calibration<br />

recommended by the ISO 8655.<br />

A fourth calibration point enables you to maximize<br />

performance at a specific volume.


PIPETMAN Concept ®<br />

Sophisticated, Simply a Click Away Yet Simple From to Perfection Operate<br />

Manage your maintenance<br />

program<br />

Pipetman Concept’s internal software allows you to set the<br />

maintenance interval (weeks or cycles) and set the alarm<br />

that prompts you when it is time to service your pipette.<br />

PC based Utility Software gives you control of your<br />

maintenance program. You can store and organize<br />

maintenance reports, read data from, export data to your<br />

Pipetman Concept.<br />

Data compilation, simply essential for Q.A. Maintenance,<br />

calibration and system settings can be displayed on screen<br />

or on a PC when using the connection kit.<br />

Sophisticated, yet simple<br />

to operate<br />

Simple “One-step” command buttons.<br />

Just click on any of the Mode<br />

buttons to access one of five pipetting<br />

modes. Click and scroll with the<br />

thumbwheel to set the volume, to<br />

navigate or to select a menu option.<br />

Rapidly change the aspirate or dispense<br />

speeds (1 to 5) at any moment<br />

with the +/- buttons.<br />

Intuitive user interface.<br />

Sophisticated electronics driving<br />

a user-friendly display with<br />

selectable menus and straightforward<br />

navigation.<br />

For more details, see the application notes insert<br />

Easy-change battery block.<br />

Optional rapid-charge stand<br />

charges Pipetman Concept<br />

pipette 80% in one hour, fully<br />

in two. Optional second battery<br />

block is kept charged and available<br />

for continuous operation.<br />

Pipetman Concept always ready-to-use...<br />

Keeping track,<br />

Pipetman Concept<br />

does it for you<br />

All factory settings,<br />

calibration data and other<br />

useful information are stored in<br />

the internal memory and can<br />

be accessed at any time.<br />

On-screen indicator shows the<br />

number of times your pipette<br />

has been readjusted.<br />

...on the rapid charge stand... using the power supply...<br />

using the additional Li-ion battery block<br />

Accessories<br />

AC-adapter Europe<br />

AC-adapter USA/Japan<br />

AC-adapter UK<br />

AC-adapter Australia<br />

Battery block<br />

Rapid Charge Stand<br />

PC connection Kit (including Utility Software)<br />

Pipetman Concept Utility Software<br />

Name Tags<br />

Ref. Number<br />

F30701<br />

F30702<br />

F30703<br />

F30704<br />

F3071165<br />

F30750<br />

F30755<br />

F3075502<br />

F3071107<br />

<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


Pipetman Concept Single-channel Models<br />

Currently not all models are available. Gilson Maximum ISO 8655 Maximum<br />

Consult your nearest local distributor for availability. Permissible Errors Permissible Errors<br />

Model Diamond Reference Volume Systematic Random Systematic Random<br />

w/o AC-adapter Tips * Number (μL) error (μL) error (μL) error (μL) error (μL)<br />

C10 • D10 F31012 0.5 ± 0.040 ≤ 0.013 ± 0.120 ≤ 0.080<br />

0.5 - 10 μL • DL10 1 ± 0.025 ≤ 0.012 ± 0.120 ≤ 0.080<br />

5 ± 0.060 ≤ 0.020 ± 0.120 ≤ 0.080<br />

10 ± 0.080 ≤ 0.025 ± 0.120 ≤ 0.080<br />

C100 • D200 F31013 5 ± 0.35 ≤ 0.10 ± 0.8 ≤ 0.30<br />

5 - 100 μL 10 ± 0.30 ≤ 0.10 ± 0.8 ≤ 0.30<br />

50 ± 0.38 ≤ 0.12 ± 0.8 ≤ 0.30<br />

100 ± 0.40 ≤ 0.15 ± 0.8 ≤ 0.30<br />

C300 • D300 F31014 20 ± 0.80 ≤ 0.16 ± 4.00 ≤ 1.50<br />

20 - 300 μL 30 ± 0.70 ≤ 0.20 ± 4.00 ≤ 1.50<br />

150 ± 0.90 ≤ 0.23 ± 4.00 ≤ 1.50<br />

300 ± 1.05 ≤ 0.30 ± 4.00 ≤ 1.50<br />

C1200 • D1200 F31015 100 ± 2.5 ≤ 0.4 ± 16.0 ≤ 6.0<br />

100 - 1200 μL 120 ± 2.4 ≤ 0.4 ± 16.0 ≤ 6.0<br />

600 ± 3.6 ≤ 0.8 ± 16.0 ≤ 6.0<br />

1200 ± 6.0 ≤ 1.2 ± 16.0 ≤ 6.0<br />

C5000 • D5000 F31016 500 ± 10 ≤ 2 ± 40 ≤ 15<br />

500 - 5000 μL 2500 ± 15 ≤ 4 ± 40 ≤ 15<br />

5000 ± 25 ≤ 7 ± 40 ≤ 15<br />

C10ml • D10ml F31017 1 mL ± 25 ≤ 4 ± 60 ≤ 30<br />

1 - 10 mL 5 mL ± 30 ≤ 8 ± 60 ≤ 30<br />

10 mL ± 50 ≤ 12 ± 60 ≤ 30<br />

* Recommended tip for establishing maximum permissible errors (ISO 8655 requirement). A large range of suitable Gilson Diamond tips is available. (See pages 22-27)<br />

Pipetman Concept Multichannel Models<br />

Currently not all models are available. Gilson Maximum ISO 8655 Maximum<br />

Consult your nearest local distributor for availability. Permissible Errors Permissible Errors<br />

Model Diamond Reference Volume Systematic Random Systematic Random<br />

w/o AC-adapter Tips * Number (μL) error (μL) error (μL) error (μL) error (μL)<br />

8x10 • DL10 F31032 1 ± 0.04 ≤ 0.02 ± 0.24 ≤ 0.16<br />

0.5 - 10 μL F31042 5 ± 0.08 ≤ 0.04 ± 0.24 ≤ 0.16<br />

12x10 10 ± 0.10 ≤ 0.06 ± 0.24 ≤ 0.16<br />

0.5 - 10 μL<br />

8x100 • D200 F31033 10 ± 0.25 ≤ 0.14 ± 1.60 ≤ 0.60<br />

5 - 100 μL F31043 50 ± 0.50 ≤ 0.20 ± 1.60 ≤ 0.60<br />

12x100 100 ± 0.80 ≤ 0.25 ± 1.60 ≤ 0.60<br />

5 - 100 μL<br />

8x300 • D300 F31034 30 ± 1.00 ≤ 0.18 ± 8.00 ≤ 3.00<br />

20 - 300μL F31044 150 ± 1.50 ≤ 0.38 ± 8.00 ≤ 3.00<br />

12x300 300 ± 2.40 ≤ 0.60 ± 8.00 ≤ 3.00<br />

20 - 300 μL<br />

* Recommended tip for establishing maximum permissible errors (ISO 8655 requirement). A large range of suitable Gilson Diamond tips is available. (See pages 22-27)


PIPETMAN ®<br />

Ultra<br />

Advanced Pipetting at Your Fingertips<br />

Pipetman Ultra is a fully adjustable,<br />

air-displacement pipette with a patented<br />

multifunctional electronic display.<br />

Designed with robustness and precision in<br />

mind, it features exclusive enhancements<br />

and innovations that address the users<br />

concern for Repetitive Strain Injuries.<br />

Twelve models cover the full range of<br />

volumes from 0.2 µL to 10 mL with single<br />

and multichannel pipettes.<br />

For more details on ergonomics,<br />

see the application notes insert<br />

Probably the Most<br />

Comfortable Pipette Ever<br />

Whether you choose the<br />

8 or 12 channel version,<br />

only two models of<br />

Pipetman Ultra Multichannel<br />

are needed to cover the<br />

entire volume range<br />

from 1 µL to 300 µL.<br />

<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


Ultra Accuracy<br />

and Precision<br />

Improved comfort when<br />

fitting and ejecting tips<br />

Exclusive G-F.I.T. System provides instant reliable<br />

seals and low ejection forces for Pipetman Ultra<br />

and Pipetman Concept Large Volume (U5000; U10mL)<br />

and Multichannel models. G-F.I.T. System is compatible<br />

with most standard tips.<br />

Exclusive patented<br />

multifunctional<br />

electronic liquid crystal<br />

display with greater<br />

readability and zero risk<br />

of parallax errors.<br />

The force required to fit and eject Diamond tips using<br />

the G-F.I.T. System can be reduced by as much as<br />

half of that of regular tip-holders. Above 40 N, the<br />

ejection force remains at a steady level around 17 N<br />

(example for Pipetman Concept Multichannel 12x300).<br />

35<br />

Reliable seal<br />

Stop & Guide<br />

Ultra comfort<br />

in daily use<br />

Ergonomic design fits naturally<br />

in your hand and requires less effort<br />

to use.<br />

Less force is needed to pipette<br />

for a smoother pipetting on a daily<br />

basis.<br />

Quick volume setting<br />

Only ten turns are needed to change<br />

from the minimum to the nominal<br />

volume setting.<br />

Easy volume adjustment<br />

The thumbwheel’s rotating friction<br />

forces are reduced to a minimum.<br />

Natural movement<br />

Three-position tip-ejector button<br />

(patented) may be set for left- or<br />

right-handed users providing a<br />

natural accessibility.<br />

The lateral position of the button<br />

respects the hand’s anatomy,<br />

requiring less force to eject the tips.<br />

2 nd ridge:<br />

works as<br />

a guide and<br />

a stop<br />

Ejection force - Newton<br />

1 st ridge:<br />

provides<br />

instant<br />

reliable seal<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Tip-holder<br />

Standard system<br />

10 20 30 40 50 60<br />

Fitting force (Newton)<br />

Small<br />

contact<br />

areas<br />

G-F.I.T. System<br />

Adjustable patented tip-ejector works as a stop-block<br />

preventing over-insertion of the tip-holder into the tip<br />

(all models except U10mL).<br />

Maximum compatibility. The position of the tip-ejector<br />

can be adjusted to adapt most standard tips.<br />

Single-channel system<br />

Small contact areas<br />

=<br />

instant reliable seals<br />

+<br />

low ejection forces<br />

Multichannel system


PIPETMAN ®<br />

Ultra<br />

Higher Productivity Through Greater Comfort<br />

Ultra GLP and<br />

security features<br />

Lockable volume with on screen<br />

display for no risk of volume<br />

change during pipetting.<br />

Cycle counters in each Pipetman<br />

Ultra record piston strokes<br />

for quality control and ease<br />

of servicing.<br />

Ultra easy<br />

maintenance<br />

Electronic adjustment is simple, only one tool is needed.<br />

Channel numbers embossed on Multichannel heads<br />

reduce the chance of accidentally reversing sample order<br />

or cross-contaminating samples in plates.<br />

Two-part tip holder for easy maintenance and cleaning.<br />

Color-coded thumbwheel and push button to identify<br />

the model (volume range) and the corresponding Diamond®<br />

Tips range.<br />

Removable tip-ejector for easy access to the user-serviceable<br />

parts. Tip-ejector is made of PVDF to avoid corrosion.<br />

Color-coded stickers protected by a plastic window to<br />

personalize your Pipetman Ultra with your name or<br />

application.<br />

10<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


Pipetman Ultra Single-channel Models Gilson Maximum ISO 8655 Maximum<br />

Permissible Errors Permissible Errors<br />

Model Diamond Reference Volume Systematic Random Systematic Random<br />

Tips * Number (μL) error (μL) error (μL) error (μL) error (μL)<br />

U2 • D10 F21021 0.2 ± 0.024 ≤ 0.012 ± 0.08 ≤ 0.04<br />

• DL10 0.5 ± 0.025 ≤ 0.012 ± 0.08 ≤ 0.04<br />

2 ± 0.030 ≤ 0.014 ± 0.08 ≤ 0.04<br />

U10 • D10 F21022 1 ± 0.025 ≤ 0.012 ± 0.12 ≤ 0.08<br />

• DL10 5 ± 0.075 ≤ 0.030 ± 0.12 ≤ 0.08<br />

10 ± 0.100 ≤ 0.040 ± 0.12 ≤ 0.08<br />

U20 • D200 F21023 2 ± 0.10 ≤ 0.03 ± 0.20 ≤ 0.10<br />

5 ± 0.10 ≤ 0.04 ± 0.20 ≤ 0.10<br />

10 ± 0.10 ≤ 0.05 ± 0.20 ≤ 0.10<br />

20 ± 0.20 ≤ 0.06 ± 0.20 ≤ 0.10<br />

U100 • D200 F21024 20 ± 0.35 ≤ 0.10 ± 0.80 ≤ 0.30<br />

50 ± 0.40 ≤ 0.12 ± 0.80 ≤ 0.30<br />

100 ± 0.80 ≤ 0.15 ± 0.80 ≤ 0.30<br />

U200 • D200 F21025 20 ± 0.50 ≤ 0.20 ± 1.60 ≤ 0.60<br />

50 ± 0.50 ≤ 0.20 ± 1.60 ≤ 0.60<br />

100 ± 0.80 ≤ 0.25 ± 1.60 ≤ 0.60<br />

200 ± 1.60 ≤ 0.30 ± 1.60 ≤ 0.60<br />

U1000 • D1000 F21026 200 ± 3 ≤ 0.6 ± 8 ≤ 3<br />

500 ± 4 ≤ 1 ± 8 ≤ 3<br />

1000 ± 8 ≤ 1.5 ± 8 ≤ 3<br />

U5000 • D5000 F21027 1000 ± 12 ≤ 3 ± 40 ≤ 15<br />

2000 ± 12 ≤ 5 ± 40 ≤ 15<br />

5000 ± 30 ≤ 8 ± 40 ≤ 15<br />

U10ml • D10ml F21028 1mL ± 30 ≤ 6 ± 60 ≤ 30<br />

2mL ± 30 ≤ 6 ± 60 ≤ 30<br />

5mL ± 40 ≤ 10 ± 60 ≤ 30<br />

10mL ± 60 ≤ 16 ± 60 ≤ 30<br />

* Recommended tip for establishing maximum permissible errors (ISO 8655 requirement). A large range of suitable Gilson Diamond tips is available. (See pages 22-27).<br />

• Pipetman Ultra single-channel pipettes are available with a calibration<br />

certificate issued by an ISO 17025 accredited laboratory. (See pages 18-19).<br />

• A Pipetman Ultra Starter kit is available for an attractive price. (See page 17).<br />

Pipetman Ultra Multichannel Models Gilson Maximum ISO 8655 Maximum<br />

Permissible Errors Permissible Errors<br />

Model Diamond Reference Volume Systematic Random Systematic Random<br />

Tips Number (μL) error (μL) error (μL) error (μL) error (μL)<br />

8x20 • DL10* F21040 1 ± 0.10 ≤ 0.08 ± 0.40 ≤ 0.20<br />

12x20 • D200 F21041 2 ± 0.10 ≤ 0.08 ± 0.40 ≤ 0.20<br />

10 ± 0.20 ≤ 0.10 ± 0.40 ≤ 0.20<br />

20 ± 0.40 ≤ 0.20 ± 0.40 ≤ 0.20<br />

8x300 • D200 F21042 20 ± 1.00 ≤ 0.35 ± 8.00 ≤ 3.00<br />

12x300 • D300* F21043 30 ± 1.00 ≤ 0.35 ± 8.00 ≤ 3.00<br />

150 ± 1.50 ≤ 0.60 ± 8.00 ≤ 3.00<br />

300 ± 3.00 ≤ 1.00 ± 8.00 ≤ 3.00<br />

* Recommended tip for establishing maximum permissible errors (ISO 8655 requirement). A large range of suitable Gilson Diamond tips is available. (See pages 22-27)<br />

• Pipetman Ultra Multichannel pipettes are available with a calibration<br />

certificate issued by an ISO 17025 accredited laboratory. (See pages 18-19).<br />

11


PIPETMAN ® P<br />

The Pipetting Standard<br />

Pipetman P is a fully adjustable, air-displacement pipette<br />

with the selected volume shown on a digital indicator<br />

(volumeter). Designed and manufactured to provide you<br />

with a range of robust, accurate and precise pipettes, eight<br />

single-channel models cover the full range of volumes from<br />

0.2 µL to 10 mL.<br />

Easy Maintenance<br />

Routine cleaning is all that is required<br />

to keep Pipetman in top condition.<br />

No lubrication is required.<br />

Parts that may come in contact with<br />

liquid samples are easy to clean or<br />

replace. The tip-holder and tip-ejector<br />

are fully autoclavable.<br />

For more details on spare parts,<br />

see the application notes insert<br />

12<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


The standard<br />

for Robustness<br />

Built to last, constructed of stainless-steel and PVDF<br />

(a plastic with very high-resistance to chemical attack).<br />

The standard for Accuracy<br />

and Precision<br />

Unique “dry seal” technology avoids using grease to obtain<br />

adequate air-tightness, and guarantees long-term performances.<br />

Thick body (handle) in PVDF to minimize the<br />

hand-warming effect during pipetting.<br />

Rigorous quality control - each piston is checked using<br />

a microscope.<br />

P2 and P10 equipped with dual position tip-ejector<br />

(Ref. F2070903), allowing the use of Diamond D10 (short)<br />

and DL10 (long) tips : a plus for protection and<br />

precision when using microtubes.<br />

P5000 and P10ml are safer and more accurate than<br />

glass pipettes. They are equipped with a polyethylene<br />

filter (Ref. F161241) that prolongs piston life expectancy<br />

and prevents contamination.<br />

Pipetman P Models<br />

Gilson Maximum<br />

Permissible Errors<br />

SO 8655 Maximum<br />

Permissible Errors<br />

Model<br />

Diamond<br />

Tips*<br />

Reference<br />

Number<br />

Volume<br />

(μL)<br />

Systematic<br />

error (μL)<br />

Random<br />

error (μL)<br />

Systematic<br />

error (μL)<br />

Random<br />

error (μL)<br />

P2<br />

P10<br />

• D10<br />

• DL10<br />

• D10<br />

• DL10<br />

F144801 0.2 ± 0.024<br />

0.5 ± 0.025<br />

2 ± 0.030<br />

F144802 1<br />

510<br />

± 0.025<br />

± 0.075<br />

± 0.100<br />

≤ 0.012<br />

≤ 0.012<br />

≤ 0.014<br />

≤ 0.012<br />

≤ 0.030<br />

≤ 0.040<br />

± 0.08<br />

± 0.08<br />

± 0.08<br />

± 0.12<br />

± 0.12<br />

± 0.12<br />

≤ 0.04<br />

≤ 0.04<br />

≤ 0.04<br />

≤ 0.08<br />

≤ 0.08<br />

≤ 0.08<br />

P20 • D200 F123600 2<br />

510<br />

20<br />

± 0.10<br />

± 0.10<br />

± 0.10<br />

± 0.20<br />

≤ 0.03<br />

≤ 0.04<br />

≤ 0.05<br />

≤ 0.06<br />

± 0.20<br />

± 0.20<br />

± 0.20<br />

± 0.20<br />

≤ 0.10<br />

≤ 0.10<br />

≤ 0.10<br />

≤ 0.10<br />

P100 • D200 F123615 20<br />

50<br />

100<br />

± 0.35<br />

± 0.40<br />

± 0.80<br />

≤ 0.10<br />

≤ 0.12<br />

≤ 0.15<br />

± 0.80<br />

± 0.80<br />

± 0.80<br />

≤ 0.30<br />

≤ 0.30<br />

≤ 0.30<br />

P200 • D200 F123601 50<br />

100<br />

200<br />

± 0.50<br />

± 0.80<br />

± 1.60<br />

≤ 0.20<br />

≤ 0.25<br />

≤ 0.30<br />

± 1.60<br />

± 1.60<br />

± 1.60<br />

≤ 0.60<br />

≤ 0.60<br />

≤ 0.60<br />

P1000 • D1000 F123602 200<br />

500<br />

1000<br />

± 3<br />

± 4<br />

± 8<br />

≤ 0.6<br />

≤ 1<br />

≤ 1.5<br />

± 8<br />

± 8<br />

± 8<br />

≤ 3<br />

≤ 3<br />

≤ 3<br />

P5000 • D5000 F123603 1000<br />

2000<br />

5000<br />

± 12<br />

± 12<br />

± 30<br />

≤ 3<br />

≤ 5<br />

≤ 8<br />

± 40<br />

± 40<br />

± 40<br />

≤ 15<br />

≤ 15<br />

≤ 15<br />

P10ml • D10ml F161201 1mL<br />

2mL<br />

5mL<br />

10mL<br />

± 30<br />

± 30<br />

± 40<br />

± 60<br />

≤ 6<br />

≤ 6<br />

≤ 10<br />

≤ 16<br />

± 60<br />

± 60<br />

± 60<br />

± 60<br />

≤ 30<br />

≤ 30<br />

≤ 30<br />

≤ 30<br />

* Recommended tip for establishing maximum permissible errors (ISO 8655 requirement). A large range of suitable Gilson Diamond tips is available. (See pages 22-27).<br />

• Pipetman P pipettes are available with a calibration certificate issued by an ISO 17025 accredited laboratory. (See pages 18-19).<br />

• A large range of Pipetman P kits is available for an attractive price. (See page 17).<br />

• A special service offer is available with Pipetman P pipettes. (See page 46).<br />

13


PIPETMAN ® Neo<br />

The Pipetting Standard with Lighter Spring Forces<br />

Pipetman Neo is an evolution of the classic<br />

Pipetman P that addresses the growing susceptibility<br />

of pipette users to repetitive strain injuries.<br />

Pipetman Neo exhibits a distinct enhancement in comfort<br />

a wide useful volume-range with the same legendary<br />

robustness, accuracy and precision as Pipetman P.<br />

Six single-channel models cover a range of volumes<br />

from 0.2µL to 1000µL.<br />

Wide Useful<br />

Volume Range<br />

Wide useful volume range: 10-100% of<br />

the nominal volume.<br />

Specifications provided at 10%, 50%<br />

and 100% of the nominal volume, as<br />

recommended by the ISO8655<br />

standard.<br />

As for all Gilson pipettes, Pipetman Neo<br />

specifications are more stringent than<br />

those required for ISO8655 compliance.<br />

14<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


Up to 50% reduction<br />

of pipetting forces<br />

Newly engineered springs are wound to provide a<br />

significant reduction of pipetting and purge forces.<br />

Up to 50% reduction of pipetting and purge forces on<br />

certain models.<br />

Pipetman Neo was elaborated on the Pipetman P,<br />

maintaining its legendary robustness, accuracy and<br />

precision.<br />

Color-coded<br />

push-buttons<br />

Color-coded push-buttons facilitate identification of the<br />

different models and corresponding quality Diamond tips.<br />

45<br />

40<br />

Dispensing<br />

Purge<br />

Plunger force (N)<br />

35<br />

30<br />

25<br />

20<br />

15<br />

P200<br />

New P200N<br />

Helps differentiate Pipetman Neo pipettes from the classic<br />

Pipetman P models.<br />

10<br />

5<br />

0<br />

0 5 10 15 20 25<br />

Piston stroke (mm)<br />

For more details on ergonomics,<br />

see the application notes insert<br />

Pipetman Neo Models<br />

Gilson Maximum<br />

Permissible Errors<br />

ISO 8655 Maximum<br />

Permissible Errors<br />

Model<br />

Diamond<br />

Tips*<br />

Reference<br />

Number<br />

Volume<br />

(μL)<br />

Systematic<br />

error (μL)<br />

Random<br />

error (μL)<br />

Systematic<br />

error (μL)<br />

Random<br />

error (μL)<br />

P2N<br />

P10N<br />

• D10<br />

• DL10<br />

• D10<br />

• DL10<br />

F144561 0.2 ± 0.024<br />

0.5 ± 0.025<br />

2 ± 0.030<br />

F144562 1<br />

510<br />

± 0.025<br />

± 0.075<br />

± 0.100<br />

≤ 0.012<br />

≤ 0.012<br />

≤ 0.014<br />

≤ 0.012<br />

≤ 0.030<br />

≤ 0.040<br />

± 0.08<br />

± 0.08<br />

± 0.08<br />

± 0.12<br />

± 0.12<br />

± 0.12<br />

≤ 0.04<br />

≤ 0.04<br />

≤ 0.04<br />

≤ 0.08<br />

≤ 0.08<br />

≤ 0.08<br />

P20N • D200 F144563 2<br />

10<br />

20<br />

± 0.10<br />

± 0.10<br />

± 0.20<br />

≤ 0.03<br />

≤ 0.05<br />

≤ 0.06<br />

± 0.20<br />

± 0.20<br />

± 0.20<br />

≤ 0.10<br />

≤ 0.10<br />

≤ 0.10<br />

P100N • D200 F144564 10<br />

50<br />

100<br />

± 0.35<br />

± 0.40<br />

± 0.80<br />

≤ 0.10<br />

≤ 0.12<br />

≤ 0.15<br />

± 0.80<br />

± 0.80<br />

± 0.80<br />

≤ 0.30<br />

≤ 0.30<br />

≤ 0.30<br />

P200N • D200 F144565 20<br />

100<br />

200<br />

± 0.50<br />

± 0.80<br />

± 1.60<br />

≤ 0.20<br />

≤ 0.25<br />

≤ 0.30<br />

± 1.60<br />

± 1.60<br />

± 1.60<br />

≤ 0.60<br />

≤ 0.60<br />

≤ 0.60<br />

P1000N • D1000 F144566 100<br />

500<br />

1000<br />

± 3<br />

± 4<br />

± 8<br />

≤ 0.6<br />

≤ 1<br />

≤ 1.5<br />

± 8<br />

± 8<br />

± 8<br />

≤ 3<br />

≤ 3<br />

≤ 3<br />

* Recommended tip for establishing maximum permissible errors (ISO 8655 requirement). A large range of suitable Gilson Diamond tips is available. (See pages 22-27).<br />

15


PIPETMAN ® FConcept ®<br />

Sophisticated, Right Pipette! Right Yet Simple Volume! to Operate Right Price!<br />

Pipetman F is a fixed-volume, air-displacement<br />

pipette. Fourteen robust models cover a large<br />

volume range from 2 µL to 5000 µL, with legendary<br />

Pipetman accuracy and precision.<br />

Right volume<br />

Can be readjusted by users in the<br />

laboratory, for dense or viscous fluids (once reset<br />

the new volume cannot be changed accidentally).<br />

Right pipette<br />

GLP compliance - no risk of volume selection errors.<br />

Using a dedicated fixed-volume Gilson pipette for a specific<br />

test assures reliable and consistent results.<br />

Right price<br />

An economical choice for clinical<br />

diagnostics, quality control, and any<br />

routine testing.<br />

Pipetman F Models Gilson Maximum ISO 8655 Maximum<br />

Permissible Errors Permissible Errors<br />

Model Diamond Reference Volume Systematic Random Systematic Random<br />

Tips* Number (μL) error (μL) error (μL) error (μL) error (μL)<br />

F2 • D200 F123770 2 ± 0.08 ≤ 0.03 ± 0.08 ≤ 0.04<br />

F5 • D200 F123771 5 ± 0.10 ≤ 0.04 ± 0.125 ≤ 0.075<br />

F10 • D200 F123772 10 ± 0.10 ≤ 0.05 ± 0.12 ≤ 0.08<br />

F20 • D200 F123604 20 ± 0.20 ≤ 0.06 ± 0.20 ≤ 0.10<br />

F25 • D200 F123775 25 ± 0.25 ≤ 0.07 ± 0.50 ≤ 0.20<br />

F50 • D200 F123778 50 ± 0.40 ≤ 0.15 ± 0.50 ≤ 0.20<br />

F100 • D200 F123784 100 ± 0.80 ≤ 0.25 ± 0.80 ≤ 0.30<br />

F200 • D200 F123605 200 ± 1.60 ≤ 0.30 ± 1.60 ≤ 0.60<br />

F250 • D1000 F123787 250 ± 3.00 ≤ 0.75 ± 4.00 ≤ 1.50<br />

F300 • D1000 F123788 300 ± 3.50 ≤ 0.75 ± 4.00 ≤ 1.50<br />

F400 • D1000 F123789 400 ± 3.60 ≤ 0.80 ± 4.00 ≤ 1.50<br />

F500 • D1000 F123790 500 ± 4.00 ≤ 1.00 ± 4.00 ≤ 1.50<br />

F1000 • D1000 F123606 1000 ± 8.00 ≤ 1.30 ± 8.00 ≤ 3.00<br />

F5000 • D5000 F123607 5000 ± 30.00 ≤ 8.00 ± 40.00 ≤ 15.00<br />

Recommended tip for establishing maximum permissible errors (ISO 8655 requirement). A large range of suitable Gilson Diamond tips is available. (See pages 22-27)<br />

• Pipetman F pipettes are available with a calibration certificate issued<br />

by an ISO 17025 accredited Laboratory. (See pages 18-19).<br />

16<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


All You Need to Get Started, in a Single Box!<br />

Our Pipette Kits now include the Pipetman P<br />

& Pipetman Ultra ranges for all of your pipetting needs.<br />

All in One<br />

Each kit contains two or three classic<br />

Pipetman P or Pipetman Ultra models<br />

plus samples of certified-quality Diamond Tips<br />

and useful accessories, such as Single Pipette<br />

Holders (except Large Volume Kit).<br />

Economical offer<br />

Save money when compared to pipettes and accessories<br />

bought separately.<br />

Pipetman Kits contents<br />

Model<br />

Pipetman<br />

Ultra<br />

Starter<br />

Kit<br />

Pipetman<br />

Micro-Volume<br />

Kit<br />

Pipetman<br />

Starter Kit<br />

Pipetman<br />

Large-Volume<br />

Kit<br />

Reference<br />

Number<br />

F267630<br />

F167500<br />

F167300<br />

F167400<br />

Pipetman<br />

models<br />

U20<br />

U200<br />

U1000<br />

P2<br />

P10<br />

P100<br />

P20<br />

P200<br />

P1000<br />

P5000<br />

P10ml<br />

Diamond Tips<br />

(racks of 96<br />

tips)<br />

D200<br />

and<br />

D1000<br />

Sterile<br />

FilterTips<br />

DFL10ST<br />

and<br />

DF100ST<br />

D200<br />

and<br />

D1000<br />

5 x D5000 tips<br />

2 x D10ml tips<br />

(no racks)<br />

Accessories<br />

• 3 Single Pipette<br />

Holders<br />

• 3 x 5 colored<br />

Name Tags<br />

• 1 Calibration key<br />

• 3 Lubricant tubes<br />

• 3 Single Pipette<br />

Holders<br />

• 10 Coloris<br />

identification clips<br />

• 1 Gilson Guide<br />

to Pipetting<br />

• 3 Single Pipette<br />

Holders<br />

• 10 Coloris<br />

identification clips<br />

• 1 Gilson Guide<br />

to Pipetting<br />

• 2 x 10 protection<br />

filters<br />

for P5000 and<br />

P10ml<br />

PIPETMAN ® Pipette kits<br />

17


ISO 17025 and Gilson Pipettes<br />

Gilson Pipette with a Calibration Certificate<br />

Issued by ISO 17025 Accredited Laboratory<br />

Around the world, accreditation of pipette testing<br />

and calibration laboratories is based on the ISO<br />

17025 international standard. ISO 17025 accreditation<br />

enables test data to be internationally validated and<br />

accepted. This system of international mutual<br />

recognition allows test data to be equivalent throughout<br />

the world because they are linked to the same<br />

metrological chain of international standard weight.<br />

Hence, the measure of the uncertainties derived from<br />

equipment, technicians, pipettes and tips which<br />

indicates the error range attributable to the measured<br />

quantities allows the accredited laboratory to attest<br />

to the pipette’s reliability and ensures that it is within<br />

acceptable limits after calibration.<br />

• Gilson ISO 17025 accredited laboratory in France provides<br />

the undisputable guarantee and confidence that our Quality<br />

System and Standard Operating Procedures have been<br />

thoroughly evaluated and approved by a legitimate third<br />

party.<br />

• Gilson offers accredited calibration for new and<br />

serviced pipettes in full compliance with the ISO 17025<br />

& ISO 8655 requirements. A certificate of calibration,<br />

approved by the French organization of accreditation<br />

(COFRAC), is delivered with each pipette. The certificate is<br />

recognized by international organizations of accreditation.<br />

In an on-going effort to address the growing demands for<br />

enhanced traceability and affordable ISO 17025 solutions,<br />

Gilson has been granted accreditation by the COFRAC for a<br />

special Gilson 3 vol. x 4 measurements method shortly after<br />

being accredited for the standardized ISO 8655 3 vol. x 10<br />

measurements method. This enables us to offer<br />

ISO 17025 calibration at an attractive price.<br />

• The standardized ISO 8655 method<br />

(3 vol. X 10 measurements).<br />

• The special Gilson method (3 vol. X 4 measurements).<br />

Gilson successfully demonstrated the absolute equivalence<br />

between the results obtained with both methods.<br />

Gilson’s pipette<br />

Calibration<br />

Laboratory in France<br />

This certificate includes the uncertainty budget defining the<br />

uncertainties for the involved measurements.<br />

Mass accreditation<br />

for pipette calibration<br />

n° 2-1630<br />

The calibration certificate with the<br />

uncertainty measurement is approved by<br />

the French Organization of Accreditation<br />

(COFRAC).<br />

18<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


New Pipettes with a Calibration<br />

Certificate Issued by the Gilson<br />

ISO 17025 Accredited Laboratory<br />

Model<br />

Reference<br />

Reference<br />

ISO 8655 Method Gilson Method<br />

3x10 measurements 3x4 measurements<br />

Pipetman F2 F123770C F123770CG<br />

Pipetman F5 F123771C F123771CG<br />

Pipetman F10 F123772C F123772CG<br />

Pipetman F20 F123774C F123774CG<br />

Pipetman F25 F123775C F123775CG<br />

Pipetman F50 F123778C F123778CG<br />

Pipetman F100 F123784C F123784CG<br />

Pipetman F200 F123605C F123605CG<br />

Pipetman F250 F123787C F123787CG<br />

Pipetman F300 F123788C F123788CG<br />

Pipetman F400 F123789C F123789CG<br />

Pipetman F500 F123790C F123790CG<br />

Pipetman F1000 F123606C F123606CG<br />

Pipetman F5000 F123607C F123607CG<br />

Pipetman P2 F144801C F144801CG<br />

Pipetman P10 F144802C F144802CG<br />

Pipetman P20 F123600C F123600CG<br />

Pipetman P100 F123615C F123615CG<br />

Pipetman P200 F123601C F123601CG<br />

Pipetman P1000 F123602C F123602CG<br />

Pipetman P5000 F123603C F123603CG<br />

Pipetman P10ml F161201C F161201CG<br />

Pipetman U2 F21021C F21021CG<br />

Pipetman U10 F21022C F21022CG<br />

Pipetman U20 F21023C F21023CG<br />

Pipetman U100 F21024C F21024CG<br />

Pipetman U200 F21025C F21025CG<br />

Pipetman U1000 F21026C F21026CG<br />

Pipetman U5000 F21027C F21027CG<br />

Pipetman U10ml F21028C F21028CG<br />

Pipetman Ultra 8x20 F21040C F21040CG<br />

Pipetman Ultra 12x20 F21041C F21041CG<br />

Pipetman Ultra 8x300 F21042C F21042CG<br />

Pipetman Ultra 12x300 F21043C F21043CG<br />

Microman M10 F148501C F148501CG<br />

Microman M25 F148502C F148502CG<br />

Microman M50 F148503C F148503CG<br />

Microman M100 F148504C F148504CG<br />

Microman M250 F148505C F148505CG<br />

Microman M1000 F148506C F148506CG<br />

Serviced Pipettes with a Calibration<br />

Certificate Issued by ISO 17025<br />

Accredited Laboratory<br />

Some Gilson service centers in the world are accredited<br />

(ISO 17025) for pipette calibration when using the<br />

gravimetric method (ISO 8655).<br />

If your nearest service center is accredited,<br />

you can ask for a certificate of calibration including<br />

a certificate of conformity for your pipette. This<br />

certificate is recognized throughout the world and linked<br />

to the International System of Units.<br />

If your local Gilson service center is not yet accredited,<br />

Gilson’s Accredited Laboratory of calibration based in<br />

France can provide you with two service offers :<br />

1 - Accredited Cofrac calibration without repair<br />

ISO 8655 3 X 10 MEASUREMENTS METHOD (no tip change)<br />

Reference<br />

PCI 001<br />

PCI 002<br />

PCI 003<br />

PCI 004<br />

Description<br />

Fixed volume Pipettes<br />

Adjustable volume Pipettes<br />

8 channel Pipettes<br />

12 channel Pipettes<br />

GILSON 3 X 4 MEASUREMENTS METHOD (no tip change)<br />

Reference<br />

PGCI 001<br />

PGCI 002<br />

PGCI 003<br />

PGCI 004<br />

Description<br />

Fixed volume Pipettes<br />

Adjustable volume Pipettes<br />

8 channel Pipettes<br />

12 channel Pipettes<br />

2 - Repair* and accredited “Cofrac calibration”<br />

ISO 8655 3 X 10 MEASUREMENTS METHOD (no tip change)<br />

Reference<br />

PCM 001<br />

PCM 002<br />

PCM 003<br />

PCM 004<br />

Description<br />

Fixed volume Pipettes<br />

Adjustable volume Pipettes<br />

8 channel Pipettes<br />

12 channel Pipettes<br />

GILSON 3 X 4 MEASUREMENTS METHOD (no tip change)<br />

Reference<br />

PGCM 001<br />

PGCM 002<br />

PGCM 003<br />

PGCM 004<br />

* Spare parts not included<br />

Description<br />

Fixed volume Pipettes<br />

Adjustable volume Pipettes<br />

8 channel Pipettes<br />

12 channel Pipettes<br />

This offer (2) includes the systematic replacement of the seal and<br />

o-ring. If Gilson determines that some parts need to be changed,<br />

Gilson will ask for your approval of a revised estimate.<br />

19


Pipette Accessories<br />

Quality Accessories for Quality Pipettes<br />

Gilson accessories are of the same high quality as<br />

Gilson pipettes. Gilson considers accessories as a part<br />

of the pipetting system. All pipettes should be stored<br />

vertically to avoid the possibility of liquid running<br />

back into, and contaminating or corroding the<br />

interior of the pipette.<br />

Carrousel<br />

Pipette Stand<br />

The carrousel holds up to seven Gilson pipettes,<br />

all models with tips fitted (except Pipetman<br />

Concept®). Its rotating head provides easy access<br />

to the desired unit. Carrousel is robust, stable and<br />

space saving, making your work bench look neat.<br />

Its heavy base prevents toppling over.<br />

Single<br />

Pipette Holder<br />

Single is designed to conveniently hold all Gilson Pipettes<br />

except Pipetman Concept where space is limited (fume<br />

hoods, sterile hoods, etc.). Stuck to any smooth, dry surface<br />

or fastened with screws, it keeps your pipette within reach.<br />

Resistant to chemicals and UV light.<br />

Trio<br />

Pipette Stand<br />

The new Trio stand features enhanced quality<br />

and reliability. Its angled, transparent design<br />

provides a convenient and secure way to store<br />

your Gilson pipettes (any models except<br />

Pipetman Concept) with exceptional<br />

stability. Its transparent body allows you to<br />

see the objects placed behind.<br />

Pipetman Concept<br />

Rapid-Charge Stand<br />

This robust stand allows to store the Pipetman Concept in<br />

an upright position while charging 80% in one hour, fully in<br />

two. A second battery block can also be kept charged and<br />

available for continuous operation.<br />

Gilson Reagent<br />

Reservoirs<br />

Disposable reagent reservoirs are ideal for dispensing<br />

reagent with multichannel pipettes (constructed of white<br />

polystyrene), two different types are available, 25 mL and<br />

50 mL, standard or sterilized (via Gamma<br />

irradiation and individually wrapped).<br />

The Gilson Reagent Reservoirs meet<br />

stringent criteria of reliability and quality.<br />

Name<br />

Tags<br />

Personalize your Pipetman Concept and Pipetman Ultra by<br />

writing your name and application on one of the colored<br />

stickers (protected by the plastic window).<br />

Coloris<br />

Identification Clips<br />

GLP-friendly, these brightly colored clips are<br />

used to identify or personalize your Pipetman<br />

pipettes. Just write your name or application<br />

to avoid mix-ups. Made of polyacetal,<br />

Coloris clips accept permanent<br />

ink and just snap into place.<br />

Description<br />

Ref. Number<br />

Carrousel for 7 pipettes<br />

F161401<br />

Single pipette holder<br />

F161406<br />

Trio, stand for 3 pipettes<br />

F161405<br />

Rapid charge stand, PIPETMAN CONCEPT<br />

F30750<br />

Reagent Reservoir 25ml, 10 packs of 10 reservoirs<br />

F267660<br />

Reagent Reservoir 50ml, 10 packs of 10 reservoirs<br />

F267670<br />

Sterilized Reagent Reservoir 25ml, 50 individually wrapped F267661<br />

Sterilized Reagent Reservoir 50ml, 50 individually wrapped F267671<br />

Set of 5 name tags, PIPETMAN ULTRA<br />

F2070901<br />

Set of 5 name tags, PIPETMAN CONCEPT<br />

F3071107<br />

10 Coloris clips, mixed colours, PIPETMAN F161301<br />

10 Coloris clips, red, PIPETMAN F161302<br />

10 Coloris clips, yellow, PIPETMAN F161303<br />

10 Coloris clips, green, PIPETMAN F161304<br />

10 Coloris clips, blue, PIPETMAN F161305<br />

10 Coloris clips, white, PIPETMAN F161306<br />

20<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


Gilson Pipetting Aid<br />

Rapid and Controlled Pipetting with Precision and Safety<br />

Comfortable<br />

Ergonomic design for increased user comfort.<br />

Quiet motorized operation.<br />

Precise and smooth finger tip control of variable<br />

speed range.<br />

High<br />

performance<br />

Powerful battery, continuous work for 8 hours<br />

(Environmentally friendly NiMH).<br />

Works with all standard glass and plastic pipettes.<br />

Fills 25 mL pipette in 4 seconds.<br />

“Wings” to enable you<br />

to rest it on the<br />

bench with no risk of<br />

contamination.<br />

Selectable operation modes according to volume and<br />

viscosity.<br />

Safe to use<br />

Safety valve and filter prevent<br />

contamination.<br />

All parts in contact with liquid<br />

are autoclavable.<br />

CE certified.<br />

Tip adapter for D5000<br />

and D10ml with filter.<br />

Ergonomic solution<br />

to handle liquid volumes<br />

from 1 mL to 10 mL.<br />

Charging and storage stand.<br />

The Gilson Pipetting Aid is<br />

always fully charged and<br />

ready to use.<br />

Gilson Pipetting Aid*<br />

Description<br />

Reference Number<br />

Gilson Pipetting Aid (220V/50Hz) with European standard plug<br />

F161250<br />

Gilson Pipetting Aid (220V/50Hz) without power supply<br />

F161240<br />

Charging stand<br />

F161288<br />

Adapter for D5000 and D10ml Diamond Tips<br />

F161287<br />

Pipette holder<br />

F161256<br />

Nose-piece<br />

F161249<br />

Nose-piece hanger<br />

F161253<br />

PTFE autoclavable filter 0.2 µm (5 units)<br />

F161245<br />

PTFE autoclavable filter 0.45 µm (5 units)<br />

F161246<br />

* Currently not available in the US - If you want to order a Gilson Pipetting Aid with a US, UK, or other countries’ power supply, please contact your local Gilson distributor.<br />

21


DIAMOND ® Tips<br />

High Quality Tips for High Quality Pipettes<br />

Genuine Gilson Diamond® tip<br />

Pipetman® specifications are valid<br />

only with the use of Diamond tips<br />

Fully traceable<br />

from the mold to<br />

your laboratory bench<br />

Pure polypropylene<br />

ensures no contamination<br />

and complete dispensing<br />

Pure Performance Tips<br />

Perfect airtight seal<br />

ensures no leak<br />

Best match between pipette and tip<br />

reduces the strain to fit & eject tips<br />

A large choice of packaging<br />

Your needs, budget and tip consumption vary according<br />

to your activity. Gilson offers one of the largest ranges of<br />

packaging from large quantity bulk tips to an innovative<br />

refill system to satisfy virtually all requirements.<br />

Bags, the Economical Solution<br />

Available in convenient small bags or in<br />

economical bulk quantities, bags are<br />

available in 2 formats:<br />

EcoPack = 10 bags of 1,000 tips<br />

EasyPack = 5 bags of 200 tips<br />

All bulk bags are sealed with a sealing strip at the top. This<br />

seal can be easily torn off the bag to access the resealable<br />

zipper which keeps the tips secure within the bag.<br />

22<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


“<br />

Your protocols and experiments require more than just generic<br />

pipette tips. Accuracy and precision of your pipetting system is intimately<br />

linked to the performance delivered by the pipette-tip couple“.<br />

Tips are essential components of your pipetting system.<br />

By not using recommended tips, you put your experiments at risk.<br />

A filter tip<br />

you can trust<br />

Fully autoclavable<br />

No contamination<br />

Sterilized Diamond® tips are free of biological<br />

contaminants with a SAL of 10 -6<br />

Volume graduations make it easy to visually<br />

check the volume pipetted<br />

Fine point<br />

Diamond® tip geometry delivers<br />

maximum accuracy<br />

TowerPack,<br />

the Innovative Refill System<br />

• Discover a quick and easy<br />

rack refill at an affordable<br />

price. Use 60% less space<br />

on your bench and 70%<br />

less plastic.<br />

Tipack<br />

Engineered to be functional, convenient<br />

and robust.<br />

• Tipacks are securely sealed with a colorcoded<br />

sticker. It includes the batch number<br />

and the tip’s maximum volume.<br />

• Robust, designed to withstand<br />

autoclaving more than 100 times.<br />

The patented Rocky Rack system<br />

available on TowerPacks and<br />

Tipacks makes it extremely easy<br />

to fit tips on a multichannel pipette.<br />

Tips will not fall off nor will they have to<br />

be manually positioned.<br />

Tip-Pipette color-coded<br />

labels and stickers<br />

Place the tower on the<br />

reload box<br />

Press down firmly<br />

with your hand<br />

The rack snaps<br />

into place<br />

23


DIAMOND ® Tips<br />

High Quality Tips for High Quality Pipettes<br />

Precision (µl)<br />

Superior Accuracy and Precision<br />

guaranteed<br />

“The maximum permissible errors always apply to the total<br />

system of piston pipette and tip. When using pipette tips not<br />

delivered by the pipette supplier, the supplier’s declaration<br />

or certificate of conformity does not apply” (ISO 8655-2)*.<br />

Diamond Tip Geometry Delivers<br />

Maximum Accuracy<br />

Diamond tips guarantee that Gilson pipettes meet<br />

our specified tolerances and deliver consistent results<br />

over time.<br />

Evaluation of the influence of different tip brands<br />

of comparable quality (A, B,....I) on the accuracy and<br />

precision of a Pipetman® P10 at 1µl.<br />

0,018<br />

0,016<br />

0,014<br />

0,012<br />

0,01<br />

0,008<br />

0,006<br />

0,004<br />

0,002<br />

Tip brands: DL-10 A B C D E F G H I<br />

Gilson specifications<br />

0<br />

-0,125 -0,1 -0,075 -0,05 -0,025 0 0,025<br />

Accuracy (µl)<br />

Results obtained in the Gilson ISO 17025 Cofrac accredited<br />

laboratory from 10 measurements of 1μL of water at 21°C<br />

using a Pipetman P10.<br />

Best Match between Pipette and Tips<br />

Reduces the Strain to Fit & Eject Tips<br />

With Diamond tips no need to jam them on “extra<br />

tight” – use of excessive force that causes muscular stress<br />

and fatigue to the arm and shoulder is greatly reduced. As a<br />

result, thumb force to eject tips is minimal.<br />

Pure Polypropylene Ensures no<br />

Contamination and Complete Dispensing<br />

Diamond tips are made from the highest grade virgin<br />

polypropylene to prevent contamination of your<br />

experiments. This polypropylene has high hydrophobic<br />

properties to ensure the lowest possible retention no matter<br />

what liquid is pipetted.<br />

Prevention<br />

of Contamination<br />

Often overlooked as a source of sample contamination, the<br />

pipette tip comes into direct contact with the sample and<br />

may contaminate the solution. Designed to meet the most<br />

stringent demands in various fields and applications such as<br />

PCR, molecular biology or cell technology.<br />

A Filter Tip You Can Trust<br />

Equipped with a high density polypropylene filter,<br />

Diamond tips contain no sealing additive which can be<br />

released in your sample.<br />

Filter porosity has been scientifically determined<br />

to constitute an effective barrier against<br />

aerosols generated by pipetting tasks.<br />

Proven high efficiency.<br />

Adding Comfort while Fitting<br />

and Ejecting Tips<br />

Loose tip fitting is a major cause of bad performance.<br />

Specifically designed for the Gilson pipettes, the<br />

diameter of the tip-collar and tip-holder of the Gilson<br />

Diamond tips are calculated to fit perfectly.<br />

*ISO 8655 is an international standard for “piston operated apparatus”. ISO 8655<br />

defines, among other things, terms and definitions regarding piston operated<br />

pipettes and their testing, testing procedure and maximum permissible errors.<br />

<br />

Sterile and non<br />

sterile versions are<br />

autoclavable to<br />

ensure perfect<br />

sterility once the rack<br />

has been opened.<br />

For more details<br />

on filter tips, see<br />

the application<br />

notes insert<br />

We performed an evaluation of different filter<br />

tip brands over a complete aerosol size range<br />

of 0.05, 0.1, 0.3, 0.5 and 1μm and found that<br />

these particles behave as the theory of filtration<br />

would predict. By further comparison of the<br />

results, we also concluded that although these<br />

filter tips are considered of the highest quality<br />

available on the market, they behave in a<br />

different manner. For example, for 1 μm<br />

particle, filter B has an efficiency of 81% as<br />

opposed to 98% for Gilson Diamond tip.<br />

24<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


Filter efficiency (% )<br />

Clean Production Environment<br />

To avoid any contamination from human contact, the<br />

manufacturing process is fully automated. Experienced<br />

personnel is equipped with protective clothing to diminish<br />

the contamination risks.<br />

All Diamond tips are manufactured<br />

and packaged in a clean room.<br />

Trace Metal Release<br />

A certificate giving evidence of the<br />

low level of potential contamination is<br />

included with Gilson Diamond tips.<br />

Sterilized tips<br />

Sterility assurance level SAL 10 -6<br />

guaranteed, using gamma irradiation.<br />

All packs are wrapped in medical device<br />

quality plastic which provides a complete<br />

shield against contamination.<br />

Indicator dots used on Gilson products<br />

undergo an irreversible color<br />

change upon sterilization.<br />

Yellow gamma dots turn<br />

red when products have<br />

been properly exposed.<br />

Free of detectable RNases, DNases, DNA, RNA and<br />

Proteases.<br />

- Regular analysis carried out by an independent laboratory.<br />

- Certificate of compliance with detailed protocols and<br />

detection levels for each batch.<br />

Filter Tip brands: Gilson A B C D<br />

100<br />

95<br />

90<br />

85<br />

80<br />

75<br />

70<br />

0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1<br />

Aerosol diameter (µm)<br />

Take a step forward in meeting<br />

your quality requirements<br />

Pipetting Systems, as for all of your<br />

laboratory instruments are part of your<br />

Quality management.<br />

Fully traceable from the mold<br />

to your laboratory bench<br />

Gilson logo means genuine<br />

Diamond tips.<br />

Identification number guarantees<br />

the manufacturing quality of the tips.<br />

Batch number on every pack.<br />

Tip model and tip volume identification on each pack<br />

and rack.<br />

Quality certificate in every box<br />

States that each batch of tips has been sampled and<br />

inspected with strict tolerances for straightness, uniformity<br />

and performance.<br />

Batch number recorded on each certificate.<br />

States that all tips comply with the CE IVD directive.<br />

Color-coded packaging<br />

Volume recognition at a glance.<br />

Helps prevent errors<br />

in the stock room and in<br />

the laboratory.<br />

Environmental Policy<br />

Gilson is concerned about<br />

disposal of plastics into the<br />

environment and knows that most of our end users also<br />

feel responsible. The company has taken a number<br />

of initiatives to minimize the impact of tip-packaging<br />

waste and has notably designed an original reload system<br />

(Tower Pack) which uses 70% less plastic than racks.<br />

All plastic parts and cardboard packaging are recyclable<br />

and marked with the recycling logo.<br />

Filter tips efficiency<br />

25


PIPETMAN DIAMOND ® Tips Concept ®<br />

Sophisticated, A large choice of Yet packaging Simple to Operate to fit your activity and budget<br />

Diamond certified tips assure optimal performance of your Pipetman pipette. The only way to ensure precision<br />

and reproducibility across the full volume range is to use Diamond precision tips with Pipetman.<br />

Tip<br />

model<br />

Pipette model<br />

P = Pipetman P, F = Pipetman F, U = Pipetman Ultra, C = Pipetman Concept, N= Pipetman Neo<br />

Tips<br />

Volume<br />

range<br />

D10<br />

P2, P10, , P2N, P10N, U2, U10, C10<br />

0.1 - 10 µL<br />

DL10<br />

D200<br />

D300<br />

P2, P10, P2N,P10N, U2, U10, U8x20, U12x20,<br />

C10, C8x10, C12x10<br />

P20 to P200, P8x200, F2 to F200, P20N to P200N<br />

U20 to U200, U8x20, U12x20, U8x300, U12x300,<br />

C100, C300, C8x100, C12x100, C8x300, C12x300<br />

P200, P200N, U200, U8x300, U12x300,<br />

C300, C8x300, C12x300<br />

0.1 - 20 µL<br />

2 - 200 µL<br />

20 - 300 µL<br />

D1000<br />

P1000, P1000N, F250 to F1000, U1000<br />

200 - 1000 µL<br />

D1200<br />

P1000, P1000N, F250 to F1000,<br />

U1000, C1200<br />

100 - 1200 µL<br />

D5000<br />

P5000, U5000, C5000<br />

1 - 5 mL<br />

D10ml<br />

P10ml, U10ml, C10ml<br />

1 - 10 mL<br />

Work safely with the Diamond Filter Tips<br />

DF10<br />

P2, P10, P2N, P10N, U2, U10<br />

0.1 - 10 µL<br />

DFL10<br />

P2, P10, P2N, P10N, U2, U10, U8x20, U12x20,<br />

C10, C8x10, C12x10<br />

0.1 - 10 µL<br />

DF30<br />

P20, P20N, F2 to F25,<br />

U20, U8x20, U12x20<br />

2 - 30 µL<br />

DF100<br />

P100, P100N, F50 to F100, U100,<br />

C100, C8x100, C12x100<br />

20 - 100 µL<br />

DF200<br />

P200, P8x200, P200N, F200, U200, U8x300, U12x300,<br />

C300, C8x300, C12x300<br />

20 - 200 µL<br />

DF300<br />

P200, P200N, U200, U8x300, U12x300,<br />

C300, C8x300, C12x300<br />

20 - 300 µL<br />

DF1000<br />

P1000, P1000N, F250 to F1000, U1000<br />

200 - 1000 µL<br />

26<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


Tipack Diamond Tips:<br />

10 Tipacks of 96 racked tips<br />

Autoclavable -Ray sterilized<br />

Tower Pack: refill system for Diamond<br />

Tips 10 racks of 96 tips<br />

Autoclavable -Ray sterilized<br />

SterilPack:<br />

400 tips<br />

individually wrapped<br />

EcoPack:<br />

box of<br />

10,000 tips<br />

(10 bags of 1,000)<br />

EasyPack:<br />

box<br />

of 1,000 tips<br />

(5 bags of 200)<br />

Empty<br />

Racks<br />

(set of 2)<br />

F161632<br />

F161905<br />

F167101<br />

F167201<br />

-<br />

F161630<br />

F161631<br />

F161791<br />

F161452<br />

F161455<br />

F167102<br />

F167202<br />

-<br />

F161450<br />

F161451<br />

F161393<br />

F161932<br />

F161937<br />

F167103<br />

F167203<br />

F161330<br />

F161930<br />

F161931<br />

F161391<br />

F161732<br />

F161735<br />

F167105<br />

F167205<br />

-<br />

F161730<br />

F161731<br />

F161737<br />

F161672<br />

F161975<br />

F167104<br />

(7 racks of 96 tips)<br />

F167204<br />

(7 racks of 96 tips)<br />

F161340<br />

F161670<br />

F161671<br />

F161793<br />

F161102<br />

F161103<br />

-<br />

-<br />

-<br />

F161100<br />

F161101<br />

F106104<br />

F161370<br />

(12 Tipacks of 50 tips)<br />

-<br />

Item<br />

-<br />

Reference Number<br />

-<br />

-<br />

F161571<br />

(3 bags of 334)<br />

F161360<br />

(1 rack)<br />

F161230<br />

(8 Tipacks of 30 tips)<br />

-<br />

Universal reload box<br />

F167100<br />

-<br />

-<br />

F161210<br />

F161220<br />

(200 tips) (1 rack)<br />

F161710<br />

F161633<br />

D1200 Diamond Tips<br />

100 - 1200 µL<br />

F161454<br />

F161935<br />

F161453<br />

F161933<br />

New slender and long tip geometry<br />

prevents the tip holder from coming<br />

in contact with wells and tubes.<br />

Designed for use even in long,<br />

narrow tubes.<br />

1000 µL<br />

F161939<br />

F161936<br />

F161938<br />

F161934<br />

Graduations at 100 µL<br />

and 1000 µL make it easy<br />

to visually check the<br />

volume pipetted.<br />

F161734<br />

F161733<br />

F161770<br />

F161673<br />

100 µL<br />

Specially designed for Gilson Pipetman<br />

Concept C1200. Compatible with<br />

Pipetman P1000 and Pipetman Ultra U1000.<br />

27


MICROMAN ®<br />

The Positive Displacement Pipetting Reference<br />

How does it work ?<br />

1. No air-to-liquid interface<br />

2. The desired volume is aspirated rapidly<br />

and completely<br />

3. The positive wiping action of the piston against<br />

the capillary wall assures accurate dispensing<br />

of even the most viscous sample and avoids any<br />

carry-over<br />

1 2 3<br />

Improve accuracy and reliability<br />

with problem liquids<br />

Perfect solution for complete and rapid pipetting of viscous<br />

and dense liquids such as oil, syrup, cosmetic cream,<br />

liquefied food, paint, glycerol or buffers.<br />

% Random error<br />

% Systematic error<br />

5<br />

3.5<br />

4.5<br />

3<br />

4<br />

Regular Air displacement Pipette<br />

2.5<br />

3.5<br />

3<br />

Regular Air displacement Pipette<br />

2<br />

2.5<br />

1.5<br />

2<br />

1<br />

1.5<br />

1<br />

0.5<br />

MICROMAN ® 0.5<br />

MICROMAN ®<br />

0<br />

0<br />

0<br />

40 70 80 85 90 95 100 % Glycerol<br />

Viscosity/Density<br />

Unique solution to avoid leakage when pipetting high vapor<br />

pressure liquids such as acetone, chloroform, alcohol,<br />

hexane or solvents.<br />

0 40 60 80 85 90 95 100 % Glycerol<br />

Viscosity/Density<br />

3.5<br />

3<br />

2.5<br />

2<br />

1.5<br />

1<br />

0.5<br />

0<br />

% Random error<br />

0<br />

Regular Air displacement Pipette<br />

MICROMAN ®<br />

40 70 80 85 90 95 100 % Glycerol<br />

Viscosity/Density<br />

% S<br />

5<br />

4.5<br />

4<br />

3.5<br />

3<br />

2.5<br />

2<br />

1.5<br />

1<br />

0.5<br />

0<br />

Reference: Gilson S.A.S. Further details available at www.gilson.com<br />

100% protection<br />

against contamination<br />

Disposable capillaries and pistons prevent contact of the<br />

pipette with corrosive vapors or liquids.<br />

Built-in tip ejector prevents user contamination.<br />

No air-to-liquid interface protects the sample from<br />

aerosol contamination.<br />

Contamination-free pipetting of liquids such as DNA<br />

fragments, PCR templates, enzyme solutions or radio<br />

labeled components.<br />

For more details on Microman, see the<br />

application notes insert<br />

Unprotected<br />

air space:<br />

risk of aerosol<br />

contamination<br />

Protected air space,<br />

no aerosol<br />

contamination -<br />

no vapors<br />

Regular Air<br />

Displacement<br />

Pipette<br />

Microman Positive<br />

Displacement<br />

Pipette<br />

28<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


Microman and<br />

Capillary Pistons (CP)<br />

Large volume range from 1 µL to 1000 µL<br />

with six different models.<br />

No need for calibration when you<br />

change the CP.<br />

Continuous volume adjustment<br />

and direct digital display.<br />

Disposable CP, capillaries made<br />

of pure polypropylene.<br />

Free of dyes, no risk of contamination<br />

from the CP’s components.<br />

Slim CP fits in even the narrowest<br />

and deepest tubes.<br />

Microman Capillary Pistons<br />

Capillary<br />

Piston<br />

Microman<br />

Model<br />

Reference<br />

number<br />

Quantity/<br />

Box<br />

Sterilized Assembled Racked<br />

in Tipack<br />

CP10 M10 F148412 192 No Yes Yes<br />

CP10 M10 F148312 960 No Yes Yes<br />

CP10ST M10 F148413 192 Yes Yes Yes<br />

CP10ST M10 F148313 960 Yes Yes Yes<br />

CP25 M25 F148112 200 No No No<br />

CP50 M50 F148113 200 No No No<br />

CP100 M100 F148414 192 No Yes Yes<br />

CP100 M100 F148314 960 No Yes Yes<br />

CP100ST M100 F148415 192 Yes Yes Yes<br />

CP100ST M100 F148315 960 Yes Yes Yes<br />

CP250 M250 F148114 200 No No No<br />

CP1000 M1000 F148560 182 No Yes Yes<br />

CP1000ST M1000 F148180 182 Yes Yes Yes<br />

Microman Models<br />

Gilson Maximum<br />

Permissible Errors<br />

ISO 8655 Maximum<br />

Permissible Errors<br />

Model<br />

Capillary<br />

Piston<br />

Reference<br />

Number<br />

Volume<br />

(μL)<br />

Systematic<br />

error (μL)<br />

Random<br />

error (μL)<br />

Systematic<br />

error (μL)<br />

Random<br />

error (μL)<br />

M10 CP10 F148501 1<br />

5<br />

10<br />

± 0.09<br />

± 0.10<br />

± 0.15<br />

≤ 0.03<br />

≤ 0.03<br />

≤ 0.06<br />

± 0.20<br />

± 0.20<br />

± 0.20<br />

≤ 0.10<br />

≤ 0.10<br />

≤ 0.10<br />

M25 CP25 F148502 3<br />

10<br />

25<br />

± 0.25<br />

± 0.27<br />

± 0.30<br />

≤ 0.08<br />

≤ 0.08<br />

≤ 0.10<br />

± 0.70<br />

± 0.70<br />

± 0.70<br />

≤ 0.30<br />

≤ 0.30<br />

≤ 0.30<br />

M50 CP50 F148503 20<br />

50<br />

± 0.34<br />

± 0.70<br />

≤ 0.20<br />

≤ 0.30<br />

± 0.70<br />

± 0.70<br />

≤ 0.30<br />

≤ 0.30<br />

M100 CP100 F148504 10<br />

50<br />

100<br />

± 0.50<br />

± 0.75<br />

± 1.00<br />

≤ 0.20<br />

≤ 0.30<br />

≤ 0.40<br />

± 1.50<br />

± 1.50<br />

± 1.50<br />

≤ 0.60<br />

≤ 0.60<br />

≤ 0.60<br />

M250 CP250 F148505 50<br />

100<br />

250<br />

± 1.50<br />

± 1.70<br />

± 2.50<br />

≤ 0.30<br />

≤ 0.30<br />

≤ 0.50<br />

± 6.00<br />

± 6.00<br />

± 6.00<br />

≤ 2.00<br />

≤ 2.00<br />

≤ 2.00<br />

M1000 CP1000 F148506 100<br />

500<br />

1000<br />

± 3.00<br />

± 5.00<br />

± 8.00<br />

≤ 1.60<br />

≤ 2.50<br />

≤ 4.00<br />

± 12.00<br />

± 12.00<br />

± 12.00<br />

≤ 4.00<br />

≤ 4.00<br />

≤ 4.00<br />

• Microman Pipettes are available with a calibration certificate issued<br />

by an ISO 17025 accredited laboratory. (See pages 18-19).<br />

29


DISTRIMAN ® and DistriTips ®<br />

Simplify Repetitive Pipetting<br />

Distriman is a positive-displacement, continuously<br />

adjustable repeater-pipette to simplify multiple<br />

dispensing when used with Gilson DistriTip<br />

syringes.<br />

Direct volume<br />

readout<br />

With the Distriman you can dispense the exact volume,<br />

eliminating tedious calculations.<br />

Only 3 Syringes<br />

are needed<br />

Micro 125 µL, Mini 1250 µL and Maxi 12.5 mL cover the<br />

entire volume range (aliquots from 1 µL to 1.25 mL).<br />

Distriman is the only repetitive pipette available capable of<br />

dispensing more than 100 aliquots.<br />

Wide selection<br />

of packaging options<br />

Each model of DistriTip is available in standard or sterilized<br />

(ST) version, in boxes of 50 syringes. Sterilized DistriTips are<br />

individually wrapped and certified free of RNase, DNase,<br />

DNA, RNA and protease.<br />

Distriman<br />

Reference Number<br />

F164001<br />

DistriTips (box of 50 syringes)<br />

Model<br />

125 µL<br />

Micro<br />

Micro ST*<br />

1250 µL<br />

Mini<br />

Mini ST*<br />

12.5 mL<br />

Maxi<br />

Maxi ST*<br />

Aliquot<br />

Range<br />

1 µL to 12.5 µL<br />

10 µL to 125 µL<br />

100 µL to 1.25 mL<br />

Reference<br />

Number<br />

F164100<br />

F164130<br />

F164110<br />

F164140<br />

F164120<br />

F164150<br />

Volume<br />

(µL)<br />

Gilson Maximum<br />

Permissible Errors<br />

Systematic<br />

error (µL)<br />

Random<br />

error (µL)<br />

ISO 8655 Maximum<br />

Permissible Errors<br />

Systematic<br />

error (µL)<br />

Random<br />

error (µL)<br />

Min. 2 ± 0.100 ≤ 0.080 ±0.20 ≤ 0.10<br />

5 ±0.125 ≤ 0.075 ±0.20 ≤ 0.10<br />

Max. 10 ±0.200 ≤ 0.100 ±0.20 ≤ 0.10<br />

Min. 20 ±0.80 ≤ 0.20 ±1.50 ≤ 0.60<br />

50 ±1.00 ≤ 0.40 ±1.50 ≤ 0.60<br />

Max. 100 ±1.00 ≤ 0.60 ±1.50 ≤ 0.60<br />

Min. 200 ±6.00 ≤ 1.00 ±12.00 ≤ 4.00<br />

500 ±7.50 ≤ 1.50 ±12.00 ≤ 4.00<br />

Max. 1000 ±10.0 ≤ 2.50 ±12.00 ≤ 4.00<br />

*ST means sterilized syringes (individually wrapped).<br />

30<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


REPETMAN ®<br />

and Repet-Tips<br />

Rapid, Reliable, Repetitive, Motorized Dispensing<br />

High<br />

performance<br />

Wide range of dispensed volume. From 1 µL to 50 mL<br />

including non-standard such as 7.46 µL, 156 µL or 12.54 mL.<br />

Simple and intuitive operation. Three operating modes:<br />

Dispensing, Automatic Dispensing and Pipetting.<br />

Compatible with most standard syringe tips.<br />

Brand PD-Tip, Eppendorf® Combitips® plus, etc.<br />

Rechargeable battery pack. Automatic battery<br />

recharging by placing Repetman on the charging stand.<br />

A second battery pack can be charged directly on the stand.<br />

Comfortable<br />

Ergonomic design. Fits naturally in either hand<br />

and increases operator comfort.<br />

Automatic tip identification. Coded<br />

syringe-plunger automatically identifies<br />

the tip size.<br />

Learn function. Digital pipetting-rate<br />

monitoring technology detects your<br />

true pipetting-rate and then<br />

automatically adjusts dispensing<br />

rhythm.<br />

Large choice of<br />

Repet-Tip packaging<br />

Eight standard or sterile Repet-Tip<br />

syringe sizes available from 0.1 mL to 50<br />

mL. Sterile Repet-Tips are individually<br />

wrapped and certified free of endotoxins<br />

and pyrogens.<br />

Repetman*<br />

Description<br />

Repetman, EU plug (230V / 50Hz)<br />

Repetman, US plug (110V / 50-60Hz)<br />

Repetman, UK plug (230V / 50Hz)<br />

Repetman, Australian plug (240V / 50Hz)<br />

NiMH battery pack<br />

*Currently not available in the US and Canada<br />

Ref. Number<br />

F164501<br />

F164502<br />

F164503<br />

F164504<br />

F164595<br />

Repet-Tips<br />

Model Non-sterile Sterile*<br />

Repet-Tip (0.1 ml, box of 100) F164510 F164515<br />

Repet-Tip (0.5 ml, box of 100) F164520 F164525<br />

Repet-Tip (1.25 ml, box of 100) F164530 F164535<br />

Repet-Tip (2.5 ml, box of 100) F164540 F164545<br />

Repet-Tip (5.0 ml, box of 100) F164550 F164555<br />

Repet-Tip (12.5 ml, box of 100) F164560 F164565<br />

Repet-Tip (25 ml, box of 50)** F164570 -<br />

Repet-Tip (25 ml, box of 25)** - F164575<br />

Repet-Tip (50 ml, box of 25)** F164580 F164585<br />

Adapter for 25/50 ml Repet-Tip (set of 10) F164591 -<br />

Adapter for 25/50 ml Repet-Tip (set of 5) - F164592<br />

* Sterile / Endotoxin-free ** One autoclavable adapter is provided in each box<br />

31


PIPETTE Replacement Parts<br />

Spare parts manufactured by Gilson are products of intensive research and stringent quality control, guaranteed<br />

to deliver value and assure reliability and precision over the long run. Having your pipettes regularly serviced by a<br />

Gilson certified and audited service center, staffed by qualified technicians and using genuine Gilson spare parts<br />

is the best way to guarantee high performance and trouble-free pipetting. Since 2003, all PIPETMAN tip-holders,<br />

pistons and tip ejector heads are embossed with the Gilson trident to protect users from counterfeit products.<br />

Gilson spare parts are only available from your local, authorized Gilson representative.<br />

Service Kits for Pipetman P<br />

Reference Number<br />

Item key P2 P10 P20 P100 P200 P1000 P5000 P10 mL<br />

Service kit 1 st level (1 tip holder, 3 piston seals and 3 O-rings) C+D+E F144501 F144502 F144495 F144496 F144497 F144498 F144499 F144503<br />

Service kit 2 nd level (1 push-button, 1 connecting nut, 1 tip<br />

ejector and 1 tip ejector adapter only for Pipetman P2/P10)<br />

A+B+F F161970 F161971 F161972 F161973 F161974 F161978 * *<br />

* Not applicable with this model. Refer to the User’s Guide (LT80117) for details.<br />

E<br />

D C<br />

B<br />

A<br />

Pipetman P Replacement parts<br />

F<br />

Reference Number<br />

Item key P2 P10 P20 P100 P200 P1000 P5000 P10 mL<br />

Push-button assembly A * * * * * * F144787 F161281<br />

Seal & O-ring (5 sets) C+D F144861 F144862 F144863 F144864 F144865 F144866 F144867 F161829<br />

Tip-holder E * * * * * * F123608 F161263<br />

Adapter for Dual-position Tip ejector (plastic part only, 5 sets) ** F144879 F144879 * * * * * *<br />

Bags of 10 filters * * * * * * F161280 F161280<br />

Bags of 100 filters ** * * * * * * F161241 F161241<br />

* Not applicable with this model. **Not shown. Refer to the User’s Guide (LT80117) for details.<br />

Pipetman F<br />

Item<br />

F2 to F20<br />

F25 to<br />

F100<br />

Reference Number<br />

F200<br />

F250 to<br />

F1000<br />

F5000<br />

Piston assembly F123845 F144611 F123846 F123847 F123848<br />

Seal & O-ring (5 sets) F144863 F144864 F144865 F144866 F144867<br />

Connecting Nut F144723 F144723 F144723 F144723 *<br />

Tip ejector F144766 F144767 F144768 F144769 *<br />

Tip holder F123353 F144602 F123305 F123371 F123608<br />

Service kit 1st level (1 tip holder, 3 piston<br />

seals and 3 O-rings)<br />

F144495 F144496 F144497 F144498 F144499<br />

Adjustment key F123674 F123674 F123674 F123674 F123674<br />

Bags of 10 filters * * * * F161280<br />

Bags of 100 filters * * * * F161241<br />

* Not applicable with this model. Refer to the User’s Guide (LT801118) for details<br />

Pipetman 8X200<br />

Item<br />

Reference Number<br />

Push-button assembly<br />

F1861081<br />

Nozzle & Piston assembly (8 sets) F161067<br />

Silicon Grease<br />

F1485012<br />

Spring (internal)<br />

F1861072<br />

Cover liquid end box (6 screws)<br />

F1861073<br />

Refer to the User’s Guide (LT801236) for details<br />

Distriman<br />

Item<br />

Reference Number<br />

Push-button assembly<br />

F164040<br />

Piston retaining assembly<br />

F164070<br />

Red flag (set of 5)<br />

F164042<br />

Retaining spring<br />

F1864052<br />

Refer to the User’s Guide (LT801285) for details<br />

32<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


M<br />

L<br />

K<br />

J<br />

G<br />

B<br />

A<br />

H<br />

R<br />

I<br />

E + D<br />

C<br />

Q<br />

P<br />

N<br />

F<br />

O<br />

Pipetman Ultra<br />

Reference Number<br />

Item key U2 U10 U20 U100 U200 U1000 U5000 U10 mL<br />

Push-button assembly A F2070152 F2070252 F2070352 F2070452 F2070552 F2070652 F2070752 F2070852<br />

Personalization window*** B F2072102 F2072102 F2072102 F2072102 F2072102 F2072102 F2072102 F2072102<br />

Recalibration tool*** C F20751 F20751 F20751 F20751 F20751 F20751 F20751 F20751<br />

Battery holder*** D F2070158 F2070158 F2070158 F2070158 F2070158 F2070158 F2070158 F2070158<br />

Battery, flat 1.5 V*** E F20710 F20710 F20710 F20710 F20710 F20710 F20710 F20710<br />

Battery compartment cover*** F F2072107 F2072107 F2072107 F2072107 F2072107 F2072107 F2072107 F2072107<br />

Connecting nut*** G F2072111 F2072111 F2072111 F2072111 F2072111 F2072111 * *<br />

Piston assembly H F2070160 F2070260 F2070360 F2070460 F2070560 F2070664 F2070760 F2070860<br />

Spring & Guide I F2070161 F2070161 F2070161 F2070161 F2070161 * * *<br />

Tip ejector assembly J F2070159 F2070159 F2070359 F2070459 F2070559 F2070659 F2070759 F2070859<br />

Tip holder, upper part K F2070117 F2070117 F2070117 F2070417 F2070517 F2070617 * *<br />

O-ring, X5 (or Seal for U2-U10) L F161901 F161902 F161908 F2070401 F2070501 F2070601 F2070701 F2070801<br />

Tip holder, lower part M F2070118 F2070218 F2070318 F2070418 F2070518 F2070618 F2070719 F2070818<br />

Tip ejector extension for U2-U10 ** F2070903 F2070903 * * * * * *<br />

Lubricant tube «End user version» *** ** * * F2070902 F2070902 F2070902 F2070902 F2070902 F2070902<br />

Bags of 10 filters ** * * * * * * F161280 F161280<br />

Bags of 100 filters ** * * * * * * F161241 F161241<br />

Safety bags for single-channel, batch of 100 ** F144875 F144875 F144875 F144875 F144875 F144875 F144875 F144875<br />

* Not applicable with this model. **Not shown *** Suitable for Pipetman Ultra Multi-Channel. Refer to the User’s Guide (LT801441) for details.<br />

Pipetman Ultra Multichannel<br />

Reference Number<br />

Item key 8X20 12X20 8X300 12X300<br />

Push-button assembly A F2073052 F2073152 F2073252 F2073352<br />

Piston assembly N F2073060 F2073060 F2073260 F2073260<br />

Airtightness Kit O F2073065 F2073065 F2073265 F2073265<br />

Tip holder assembly, G-FIT System P F207306306 F207306306 F207326306 F207326306<br />

Tip holder assembly standard P F2073063 F2073063 F2073263 F2073263<br />

Wire clip Q F207306407 F207306407 F207306407 F207306407<br />

Ejector cover kit R F2073059 F2073159 F2073259 F2073359<br />

Reassembly tool ** F2073001 F2073001 F2073201 F2073201<br />

Safety bags for multichannel, batch of 100 ** F2073270 F2073270 F2073270 F2073270<br />

**Not shown. Refer to the User’s Guide (LT801462) for details.<br />

Microman<br />

Item<br />

Reference Number<br />

Button assembly, blue, M10<br />

F148568<br />

Button assembly, blue, M100<br />

F148569<br />

Button assembly, blue, M25<br />

F148615<br />

Button assembly, blue, M50<br />

F148616<br />

Button assembly, blue, M250<br />

F148618<br />

Button assembly, blue, M1000<br />

F148619<br />

Refer to the User’s Guide (LT801502) for details<br />

Pipetting Aid<br />

Item<br />

PTFE Filter, 0.2 µm, autoclavable (package of 5)<br />

PTFE Filter, 0.45 µm, autoclavable (package of 5)<br />

Nosepiece<br />

Nosepiece Hanger<br />

Adaptor for D5000 and D10mL Diamond® Tips<br />

Refer to the User’s Guide (LT801478) for details<br />

Reference Number<br />

F161245<br />

F161246<br />

F161249<br />

F161253<br />

F161287<br />

33


PIPETTE Replacement Parts<br />

Pipetman Concept<br />

Reference Number<br />

Item key C10 C100 C300 C1200 C5000<br />

Battery block*** A F3071165 F3071165 F3071165 F3071165 F3071165<br />

Adjustable hook*** B F3071110 F3071110 F3071110 F3071110 F3071110<br />

Personalization window*** C F3071103 F3071103 F3071103 F3071103 F3071103<br />

Connecting nut D F2072111 F2072111 F2072111 F2072111 *<br />

Piston assembly E F3071252 F3071352 F3071452 F3071552 F3071652<br />

Return spring F F2070113 F2070113 F2070113 F2070113 *<br />

Spring guide G F307115451 F307115451 F307115451 F307115451 *<br />

Tip ejector assembly H F2070159 F2070459 F2070559 F2070659 F2070759<br />

Tip holder, upper part I F2070117 F2070417 F307145302 F2070617 *<br />

O-ring, X5 (or Seal for C10) J F161902 F2070401 F307145351 F2070601 F2070701<br />

Tip holder, lower part K F2070218 F2070418 F307145301 F2070618 F2070719<br />

Tip ejector adapter for C10 ** F2070903 * * * *<br />

Lubricant tube «End user version» *** ** F3070902 F3070902 F3070902 F3070902 F3070902<br />

Bags of 10 filters ** * * * * F161280<br />

Bags of 100 filters ** * * * * F161241<br />

* Not applicable with this model. **Not shown *** Suitable for Pipetman Concept Multi-Channel. Refer to the User’s Guide (LT801489) for details.<br />

G<br />

F<br />

E<br />

K<br />

J<br />

I<br />

H<br />

D<br />

C<br />

A<br />

P<br />

O<br />

N<br />

B<br />

L<br />

M<br />

Pipetman Concept Multichannel<br />

Reference Number<br />

Item key 8X10 12X10 8X100 12X100 8X300 12X300<br />

Piston assembly L F3073254 F3073254 F3073354 F3073354 F3073454 F3073454<br />

Airtightness Kit M * * F3073360 F3073360 F2073265 F2073265<br />

Tip holder assembly, G-FIT System N F3073255 F3073255 F3073355 F3073355 F307326306 F307326306<br />

Wire clip O F207306407 F207306407 F207306407 F207306407 F207306407 F207306407<br />

Ejector cover kit P F307325051 F307425051 F307335051 F307435051 F2073259 F2073359<br />

Reassembly tool ** * * F3073301 F3073301 F2073201 F2073201<br />

* Not applicable with this model. **Not shown. Refer to the User’s Guide (LT801489) for details.<br />

34<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


402 Dilutor-Dispenser<br />

<strong>Liquid</strong> <strong>Handling</strong> at the Touch of a Button<br />

High<br />

performance<br />

Nine pre-stored tasks that can be linked: dilute, dilute<br />

serially, dispense aliquots or variable volumes,<br />

pipette, rinse, mix, titrate, measure volume and prime.<br />

High volume range from 1µL to 99 mL.<br />

Provides the same high precision and accuracy as Gilson<br />

pipettes.<br />

Adjustable flow rate.<br />

Minimal cross-contamination with the adapter kit for tips.<br />

Improve<br />

productivity<br />

Faster than any other pipettor for repetitive liquid<br />

transfer.<br />

Fully programmable: ability to save and recall up to 99<br />

methods.<br />

No need for calculation of dilution ratios.<br />

Single instrument to perform all liquid transfer tasks.<br />

Increase<br />

reliability - GLP<br />

Eliminates technician to technician variability.<br />

Coded protection of methods.<br />

Calibration certificate, IQ/OQ procedure.<br />

LED indicator for error-free manipulation.<br />

Minimize<br />

costs<br />

Maintenance-free - permanently calibrated.<br />

Reduces preparation time and consumption of expensive<br />

reagents.<br />

Highly versatile with upgrade possibilities and the<br />

tip-adapter kit.<br />

Comfort<br />

Lightweight probe (48g) and low activation forces<br />

make the 402DD even more comfortable than electronic<br />

motorized pipettes.<br />

Menu-driven software.<br />

Model (without syringes, which are sold separately)<br />

Reference Number<br />

402 Dilutor-Dispenser, single-syringe, 110-220V F410514<br />

402 Dilutor-Dispenser, single-syringe, 220V (French version) F410514F<br />

402 Dilutor-Dispenser, dual-syringe, 110-220V F410515<br />

402 Dilutor-Dispenser, dual-syringe, 220V (French version) F410515F<br />

No contamination :<br />

the probe may be fitted<br />

with Diamond Tips.<br />

Accessories<br />

Reference Number<br />

Adapter Kit for disposable tips F4015015<br />

Syringe, 100 µL 25025341<br />

Syringe, 250 µL 25025342<br />

Syringe, 500 µL 25025347<br />

Syringe, 1 mL 25025343<br />

Syringe, 5 mL 25025344<br />

Syringe, 10 mL 25025345<br />

Additional Accessories<br />

Transfer Tubing, 1 mL, FEP,<br />

1.0 x 2.0 x 1300 mm<br />

Transfer Tubing, 2 mL, FEP,<br />

1.5 x 2.0 x 1300 mm<br />

Transfer Tubing, 5 mL, FEP,<br />

1.5 x 2.1 x 3000 mm<br />

Transfer Tubing, 10 mL, FEP,<br />

1.5 x 2.1 x 6000 mm<br />

Reference Number<br />

F4015031<br />

F4015032<br />

F4015033<br />

F4015034<br />

Syringe, 25 mL 25025346<br />

35


MINIPULS Evolution ®<br />

Laboratory Peristaltic pump<br />

The Minipuls evolution® is the newest innovation<br />

from the makers of the Minipuls TM 3, offering<br />

unmatched flexibility and performance for liquid<br />

transfer applications.<br />

Unbeatable flow rate range<br />

from 0.2 μL/min to 340 mL/min<br />

Stackable pump heads<br />

for up to 16 channels<br />

Medium and high flow pump heads<br />

can be used simultaneously in the<br />

same module<br />

Reproducibility<br />

of flow rate on all channels<br />

with a variation ≤ 0.1%<br />

0.01 rpm readability below<br />

10 rpm, perfect for accurate<br />

flowrate adjustment<br />

Optimised 6-roller design limits<br />

pulsations<br />

Offers back pressure resistance up<br />

to 0.3MPa (42psi)<br />

36<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


1<br />

How to select the most<br />

appropriate configuration?<br />

Speed control module<br />

Ref. F110701<br />

2<br />

Select the pump head(s):<br />

Gilson robustness<br />

and reliability<br />

Safe and durable design, can work 24/7.<br />

Stainless steel rollers for great durability and chemical<br />

resistance.<br />

The stepper motor and the spring loaded cartridges assure a<br />

high precision of flow rate despite tubing stretching:<br />

less than 2% variation after 24h in operation.<br />

Quick, flexible<br />

& safe set up<br />

Cartridges snap in & out of the pump head<br />

for fast tubing change - no need to remove<br />

the pump head from the speed control<br />

module.<br />

Pump heads can be changed within<br />

seconds even while pump is operating - no<br />

tool required.<br />

Adjustable tubing occlusion for simple and<br />

fine pressure adjustment.<br />

Intuitive software interface with large LCD<br />

screen.<br />

Clear setting display<br />

on the large LCD screen<br />

Start/Stop.<br />

Variable flow rate and direction.<br />

* Consult your local distributor for details / availability.<br />

PATENTED<br />

PATENTED<br />

PATENTED<br />

Prime mode : purge tubing at the touch of the button.<br />

3<br />

4<br />

Select the appropriate tubing:<br />

Select the footswitch pump control for increased<br />

comfort Ref. F1077081<br />

MF1 pump head,<br />

with 1 cartridge,<br />

0.2µL/min to 70mL/min<br />

Ref. F110705<br />

MF4 pump head,<br />

with 4 cartridges, 0.2µL/min to<br />

70mL/min<br />

Ref. F110706<br />

Stack up to 4 MF pump heads<br />

together for up to 16 channels<br />

HF2 pump head,<br />

with 2 cartridges,<br />

1mL/min to 340mL/min<br />

Ref. F110707*<br />

Stack up to 3 HF pump heads<br />

together for up to 6 channels<br />

• Check the appropriate material according<br />

to your sample’s chemical compatibility<br />

• 4 types of tubing are available to choose from:<br />

- PVC for standard use<br />

- Silicone for best biocompatibility<br />

- Pharmed® for increased lifetime - conforms<br />

to USP & FDA class 4<br />

- Isoversinic® for high chemical compatibility<br />

• Check the maximum required flow-rate<br />

• Choose tubing internal diameter, connectors and extensions<br />

from the table on page 40<br />

Pharmed® and Isoversinic® are registered trademarks of Norton Performance Plastic Corp.<br />

37


PIPETMAN MINIPULS 3Concept ®<br />

Sophisticated, Pulse-free Flow Yet Peristaltic Simple to Pump Operate<br />

High performance<br />

and versatile<br />

Pulse-free flow (10 stainless steel rollers!).<br />

Excellent flow-rate accuracy and reproducibility.<br />

Wide flow-rate range from 0.3 µL/min to 220 mL/min.<br />

Operates at higher pressures than competitor products<br />

(up to 0.5 MPa).<br />

Low noise operation.<br />

Reliable and<br />

robust<br />

High chemical resistance material (drive module and<br />

pump heads).<br />

Motor speed stability (high torque stepper motor).<br />

Built-in overflow system, in case of tubing leakage.<br />

Adjustable cams allow fine flow-rate<br />

adjustment to minimize tubing wear.<br />

Two-stop calibrated tubing makes it<br />

easy to install tubing on the pump head.<br />

Item<br />

Max Flow<br />

Rate<br />

Number of<br />

channels<br />

Reference<br />

Number<br />

Pump Module Minipuls 3 F155001<br />

R1 Pump Head<br />

R2 Pump Head<br />

R4 Pump Head<br />

R8 Pump Head<br />

R2/HF Pump Head (High Flow)<br />

R4/HF Pump Head (High Flow)<br />

up to 30<br />

mL/min<br />

up to 30<br />

mL/min<br />

up to 30<br />

mL/min<br />

up to 30<br />

mL/min<br />

up to 220<br />

mL/min<br />

up to 220<br />

mL/min<br />

1 F117604<br />

2 F117800<br />

4 F117606<br />

8 F117608<br />

2 F117830<br />

4 F117831<br />

A large choice of suitable tubing is available (see page 40)<br />

38<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


MINIPULS 3<br />

Electrophysiology of rat brain cells<br />

To measure electrical signals and intracellular calcium concentrations<br />

of neuronal cells at the same time, Mr. Kwang-Hyun<br />

Cho, PhD, a postdoctoral researcher from the College of Medicine<br />

at the Catholic University of Korea, uses a microscope<br />

focusing on a perfusion chamber drained by a Minipuls 3. The<br />

neuronal cells come from a rat brain slice bathed in a buffer<br />

inside the chamber. This buffer is an oxygenated saline solution<br />

that ensures the viability of the neuronal<br />

cells, which are very sensitive to oxygen.<br />

“ ”<br />

The Minipuls 3 is very convenient<br />

for the re-circulation of solutions<br />

says Doctor Kwang-Hyun Cho when referring<br />

to a key benefit of the pump. Engineered with<br />

a 10-roller rotor, the Minipuls 3 produces<br />

smooth pulse-free flows, which eliminate<br />

siphoning or clogging phenomenon, a significant<br />

advantage when circulating sensitive<br />

neuronal cells.<br />

MINIPULS Evolution ®<br />

Study of bacterial biofilm<br />

In the Institute of Biology at the Leiden University,<br />

the molecular biology team seeks to identify Pseudomonas<br />

(Pseudomonas putida) genes and traits<br />

involved in efficient competitive root colonisation<br />

in order to understand how bacteria survive,<br />

proliferate, and compete in the rhizosphere after<br />

bacterisation of seeds. The Minipuls evolution is<br />

used to study bacterial biofilms in flowcell chambers.<br />

Bacteria grow in flowcell chambers fed by an oxygenated<br />

solution and media. The Minipuls evolution is used to<br />

bring this solution to the chambers and recycle it.<br />

The growth media was delivered at 0.125 mL/min to the flowcell<br />

system. Elen Lagendijk, technical assistant at the molecular<br />

and biology department, says<br />

“<br />

that<br />

Chamber<br />

Chamber<br />

Growth media<br />

tubing inlet<br />

Applications<br />

Inlet tubing<br />

tubing outlet<br />

Outlet tubing<br />

Flowcell chambers<br />

Minipuls 3<br />

waste<br />

bubble trap<br />

Oxygenated<br />

solution<br />

one of the outright benefits of the Gilson Minipuls evolution peristaltic<br />

pump is that it enables the operator to replace tubing, add or remove channels while the pump<br />

is running without interrupting the flow in the other chambers…<br />

”<br />

39


MINIPULS Accessories<br />

How to select the right tubing<br />

for your Minipuls 3 or Minipuls evolution?<br />

A collection of tables and charts is available at<br />

www.gilson.com to be used as a guide for selecting the<br />

appropriate tubing.<br />

Most suitable material according to your sample’s<br />

chemical compatibility.<br />

Large variety of Internal Diameters to reach desired<br />

flow rates.<br />

Appropriate connectors and extension tubing.<br />

Tubing for R1, R2, R4, R8, MF1 & MF4 pump heads<br />

(length = approx 40 cm/ 16in)<br />

Tubing for R2HF, R4HF & HF2 high flow pump heads<br />

(length = 3m / 118in )<br />

Material<br />

Internal diameter (mm)<br />

Reference tubing<br />

(calibrated tubing)<br />

Color coded stops<br />

Extension tubing<br />

(3m/118in)<br />

Connectors<br />

Minipuls 3<br />

Maximum Flow rate<br />

(mL/min)<br />

Minipuls evolution<br />

Maximum Flow rate<br />

(mL/min)<br />

Material<br />

Internal diameter (mm)<br />

Reference tubing<br />

(calibrated tubing)<br />

Minipuls 3<br />

Maximum Flow rate<br />

(mL/min)<br />

Minipuls evolution<br />

Maximum Flow rate<br />

(mL/min)<br />

PVC<br />

ISOVERSINIC®<br />

SILICONE<br />

PHARMED®<br />

0,25 F117932 F117952 F117985 0,407 0,574<br />

0,38 F117933 F117953 F117985 0,695 1,22<br />

0,51 F117934 F117954 F117985 1,415 1,90<br />

0,76 F117936 F117956 F117986 2,1 3,00<br />

1,02 F117938 F117958 F117986 4,1 6,0<br />

1,30 F117940 F117960 F1179941 6,2 9,0<br />

1,52 F117942 F117962 F1179941 9 14<br />

1,65 F117943 F117963 F1179941 10 16<br />

2,06 F117945 F117965 F1179941 16 25<br />

2,29 F117946 F117966 F1179941 20 29<br />

2,79 F117948 F117968 F1179951 23 39<br />

3,16 F117949 F117969 F1179951 29 47<br />

0,5 F1817741 F117740 F117986 1,8 2,9<br />

1,0 F1817743 F117742 F117986 4 10<br />

2,0 F1817745 F117744 F1179941 13 24<br />

3,0 F117747 F117746 F1179951 27 55<br />

4 F117749 F117748 - 33 70<br />

0,6 F1825111 F1825131 F117986 1,5 3,2<br />

1,0 F1825112 F1825132 F117986 4 7<br />

2,0 F1825113 F1825133 F1179951 15 21<br />

2,8 F1825114 F117975 F1179951 23 31<br />

0,5 F1825101 F1825121 F117986 1,4 2,5<br />

1,0 F1825102 F1825122 F117986 5 7<br />

2,0 F1825103 F1825123 F1179941 15 24<br />

PVC<br />

ISOVERSINIC®<br />

SILICONE<br />

PHARMED®<br />

2,06 F117965 24 33<br />

2,29 F117966 29 41<br />

2,79 F117968 41 66<br />

3,16 F117969 49 85<br />

4,0 F117970 75 128<br />

5,0 F117980 113 179<br />

6,0 F117981 163 218<br />

8,0 F117982 213 340<br />

2,0 F117744 23 30<br />

3,0 F117746 48 67<br />

4,0 F117748 86 120<br />

6,0 F117750 181 246<br />

2,0 F1825133 25 31<br />

3,0 F117975 44 57<br />

4,0 F117976 71 105<br />

5,0 F117977 115 148<br />

6,0 F117978 150 207<br />

7,0 F117979 220 300<br />

2,0 F1825123 26 31<br />

3,2 F1825124 57 77<br />

6,4 F1825125 171 240<br />

Pharmed® and Isoversinic® are registered trademarks<br />

of Norton Performance Plastic Corp.<br />

40<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


GILSON Safe Aspiration Station<br />

The Best Solution for Safe <strong>Liquid</strong> Aspiration<br />

Comfort<br />

& flexibility<br />

Quiet operation<br />

Motor starts only when vacuum pressure drops.<br />

Compact design and small footprint<br />

Allows for efficient use of space in laminar flow cabinets.<br />

Adjustable aspiration speed allows for quick and accurate<br />

aspiration.<br />

Handle accommodates different types of pipettes to aspirate<br />

from a variety of vessels.<br />

Always ready to use<br />

Just press the handle-button to aspirate.<br />

Convenient coupling for quick bottle emptying.<br />

Safe &<br />

contamination free<br />

Closed, stand-alone unit designed to prevent<br />

contamination hazards.<br />

All parts in contact with the liquid are autoclavable.<br />

In-line hydrophobic filter traps aerosols.<br />

Level detection to prevent overflow.<br />

Unbreakable bottle.<br />

Connect two handles to the Gilson Safe Aspiration Station<br />

with the Y-shape connector.<br />

Description<br />

Gilson Safe Aspiration Station<br />

Gilson Safe Aspiration Kit<br />

Y-shape Connector<br />

Reference Number<br />

F110741<br />

F110742<br />

F1077418<br />

Cell culture<br />

Cell culture<br />

ELISA test<br />

<strong>Liquid</strong> aspiration<br />

(supernatant, etc.)<br />

Gilson Safe Aspiration Kit<br />

• 1 handle + tubing set + 1 holder<br />

• 1 stainless steel needle adaptor<br />

• 1 tip* adaptor<br />

• 1 tip adaptor with tip* ejector<br />

• 8-needle stainless steel adaptor<br />

• 8-tip adaptor with tip* ejector<br />

* Compatible with Diamond®tips : DL10, DFL10, DF30, DF100, D200, DF200, D300, DF300<br />

41


PIPETMAN GmCLab Concept ®<br />

Sophisticated, Quick and Safe Yet Spin Simple with Your to Operate Personal Mini-Centrifuge<br />

GmCLab is a fixed-speed personal mini-centrifuge<br />

that quickly separates particles from the supernatant<br />

in a solid-liquid mixture or spin down liquids to the<br />

bottom of a microtube.<br />

Compact<br />

design<br />

Small footprint allows for easy integration on a busy<br />

workbench.<br />

Accommodates 8 micro-tubes of 1.5 or 2.0 ml, 2 strips of<br />

8-PCR (0.2 ml) tubes or 16 single PCR tubes.<br />

Simple<br />

to use<br />

Simple spin activation by closing the lid.<br />

Pinch-type connector to quickly exchange<br />

rotors - no tool needed.<br />

Lid opens up to an angle of 160° to allow easy<br />

access to the tubes.<br />

Dynamic brake for emergency stop.<br />

Robust<br />

Reinforced lid hinge cylinders.<br />

Maintenance-free.<br />

One-year warranty.<br />

GmCLab<br />

Description<br />

GmCLab, EU plug (230 V / 50-60 Hz)<br />

GmCLab, US plug (120 V / 50-60 Hz)<br />

GmCLab, UK plug (230 V / 50-60 Hz)<br />

GmCLab, AU plug (230 V / 50-60 Hz)<br />

GmCLab, JP plug (100 V / 50-60 Hz)<br />

Rotor for 1.5/2.0 ml tubes<br />

Rotor for 8-PCR tube strips<br />

Reference Number<br />

F110731<br />

F110732<br />

F110733<br />

F110734<br />

F110735<br />

F1077303<br />

F1077304<br />

42<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


LabStir<br />

Quality Mixing with an Ultra-Flat Stirrer<br />

Ultra-flat<br />

design<br />

Ultra flat: only 12 mm thick, use is only limited by<br />

the container height. Small footprint.<br />

Ultra light (0.3 Kg). Easy to move and to store where<br />

space is limited.<br />

High<br />

performance<br />

Quality mixing with the alternating stirring mode<br />

(forward / reverse every 30 sec.).<br />

Friction-free drive technology<br />

minimizes heat transfer to the solution.<br />

Accommodates containers up to<br />

800 mL and 90 mm (3.54 in.) in diameter.<br />

Variable speed control<br />

(15 - 1500 rpm) for efficient<br />

mixing, even for solutions of<br />

medium viscosity.<br />

GVLab<br />

Clearly Simple and Functional<br />

GVLab is a “touch-on” fixed speed vortex mixer<br />

that quickly mixes solutions or media<br />

contained in various formats of tubes or vials.<br />

Quality<br />

Compact design<br />

with no moving parts inside<br />

for a robust and reliable<br />

module.<br />

Maintenance-free.<br />

Three-year warranty.<br />

Safe<br />

to use<br />

Impervious to dust and splashes.<br />

Safe in Class II explosive environments.<br />

CE certified, cULus certified.<br />

LabStir<br />

Model<br />

LabStir (100 to 240V / 50-60Hz), EU plug<br />

LabStir (100 to 240V / 50-60Hz), US plug<br />

LabStir (100 to 240V / 50-60Hz), UK plug<br />

Compact design.<br />

Just touch the container against the<br />

pad for instant vigorous and uniform vortexing action.<br />

Accommodates any size of tubes<br />

and vials up to 30 mm (1.18 in.) diameter.<br />

Reference Number<br />

F110711<br />

F110712<br />

F110713<br />

GVLab<br />

Model<br />

GVLab (100 to 240V / 50-60Hz) EU plug<br />

GVLab (100 to 240V / 50-60Hz) US plug<br />

GVLab (100 to 240V / 50-60Hz) UK plug<br />

GVLab (100 to 240V / 50-60Hz) AU plug<br />

Reference Number<br />

F110721<br />

F110722<br />

F110723<br />

F110724<br />

Quality<br />

Sturdy base and housing for stability and<br />

minimal vibration during use.<br />

Special tube pad design prevents liquids from damaging<br />

the electronics.<br />

Maintenance-free. Three-year warranty.<br />

CE certified, cULus certified.<br />

43


Services<br />

Pipettes are precision instruments used daily in<br />

routine laboratory work and often involved in critical<br />

laboratory applications. Like any other instrument<br />

they need to be serviced and calibrated regularly to<br />

ensure that they perform to the highest standards.<br />

In line with the ISO 8655, Gilson recommends<br />

disassembling, cleaning, replacement of worn parts<br />

and checking of the calibration every 6 months or<br />

at least once a year. Gilson is a worldwide network<br />

of specialists present in more than 50 countries<br />

offering a breadth of services to address the<br />

demanding requirements of international standards,<br />

Good Laboratory Practices and internal procedures.<br />

Ultimately, we work to provide you with flexible<br />

solutions to extend pipette lifetime and assure you<br />

the highest level of continued accuracy and precision<br />

at a minimum cost.<br />

Gilson Service network<br />

of trained distributors<br />

All Gilson technicians are highly qualified after<br />

extensive training by Gilson at the factory and share<br />

Gilson’s experience. Their skills are continuously improved<br />

for new or upgraded products. Gilson Service Centers are<br />

routinely audited to check their abilities.<br />

Gilson preventive maintenance<br />

- repair & calibration services<br />

Pipettes are a staple of most laboratories and probably<br />

one of the most extensively used pieces of equipment.<br />

The pipette is made of a variety of mechanical and/or<br />

electronic parts moving against each other that are often<br />

exposed to corrosive or hazardous chemicals. This exposure<br />

may result in barely visible damage that may not be discovered<br />

unless regular service has been carried out. For example:<br />

• The pipette has been tested on the balance, and is imprecise<br />

and/or inaccurate.<br />

• The pipette leaks after a long period of use.<br />

• The pipette leaks after having been exposed to<br />

contaminating liquids.<br />

• The piston seal and/or O-ring are worn out.<br />

• The stainless steel piston is scratched.<br />

Gilson Service Center gives you the<br />

priority<br />

• No surprises, you pay for what is on the<br />

estimate<br />

• We propose various service offers adapted<br />

to your budget<br />

• We guarantee that Gilson genuine spare<br />

parts are used in all repairs<br />

• We guarantee that the personnel is<br />

regularly audited and the equipment<br />

checked daily<br />

• The tip-holder or other parts (tip-ejector, push<br />

button, connecting nut, etc) are damaged, chemically<br />

attacked or worn.<br />

Servicing your pipette regularly will provide you peace of<br />

mind regarding its performance and reliability. Gilson offers<br />

flexible service solutions that suit your environment:<br />

• Diagnosis, repairs, and calibration.<br />

• Preventive maintenance contract to implement the<br />

level of service most appropriate to your needs (what,<br />

how often, number of pipettes, cycle time, etc.).<br />

• Calibration by gravimetric method to check the performance<br />

of your pipettes according to the ISO 8655 standard,<br />

including ISO17025 calibration with the Calibration certificate<br />

delivery, adapted to your budget (see page 18).<br />

44<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


On-Site<br />

service<br />

Gilson’s qualified technicians are available to visit your<br />

facility for any of the following:<br />

• Diagnosis: Check that your Gilson pipettes function<br />

correctly and are mechanically sound.<br />

• Repairs: Replacement of genuine spare parts.<br />

• Upgrade of Pipetman: Systematic replacement of key<br />

components with upgraded parts.<br />

• Pipette Clinics: Servicing of all Gilson pipettes. Servicing<br />

may include cleaning, decontamination, repair,<br />

(adjustment if needed) and calibration.<br />

The “Center of Excellence”<br />

label<br />

With a clear focus on developing the quality of service to<br />

the Gilson pipette users, the company launched the “Center<br />

of Excellence” audit campaign in 2005. The “Center of<br />

Excellence” label rewards the centers that fully fulfill<br />

all Gilson’s requirements. While no detail is overlooked,<br />

the main objective of the audits is to accompany the entire<br />

Gilson network towards excellence of their service. Audits<br />

provide guidance to support the implementation of the<br />

necessary means to achieve excellence.<br />

The Center of Excellence Certificate and the use of the<br />

numbered label ensure the highest quality of Gilson service<br />

and guarantee that the Service Center performs repairs and<br />

calibration according to Gilson’s requirements:<br />

1. Undergo regular Gilson audits on technical aspects,<br />

personnel skills, service quality and service offers.<br />

2. Follow regular training.<br />

3. Repair and calibrate in accordance with Gilson’s servicing<br />

procedures or procedures validated by Gilson.<br />

4. Repair the entire Gilson pipette range.<br />

5. Repair Gilson pipettes with genuine spare parts.<br />

6. Monitor environmental conditions.<br />

7. Use correct balances (including 6-digit balance to<br />

calibrate volumes < 20 µl).<br />

8. Maintain a comprehensive Service offer that includes:<br />

a. Diagnosis, repairs, and calibration by gravimetric<br />

method (ISO 8655 Standard).<br />

b. Maintenance.<br />

c. On-site pipette service.<br />

9. Comply with local standards and regulations.<br />

10. Refuse sales of Gilson spare parts to unauthorized<br />

companies.<br />

Companies that have successfully completed the Gilson’s<br />

recommendation program may use the Center of Excellence<br />

label as a graphic symbol to let clients know they have<br />

demonstrated the expertise<br />

required to diagnose, repair and<br />

calibrate.<br />

45


Services<br />

Gilson<br />

training *<br />

Gilson’s distributors conduct comprehensive seminars to<br />

train you or your personnel. Training programs cover<br />

all aspects of service and operation of your pipettes.<br />

Gilson’s local representatives have completed extensive<br />

training in all aspects of service and operation of Gilson<br />

products and services. Your local distributor can offer you<br />

extensive pipette training covering topics such as:<br />

• Good handling practices, gesture and posture.<br />

• Use and applications.<br />

• GLP requirements, quality control, applicable standards,<br />

traceability, and record keeping.<br />

• Preventive maintenance and calibration.<br />

Contact your nearest Gilson Service Center<br />

for availability of these offers.<br />

Do-it-yourself performance<br />

check: Weighing Kit<br />

The weighing kit is intended for end-users’ use to check the<br />

performance of their Gilson pipettes across the full range of<br />

volumes from 1 μL to 10 mL. It consists of :<br />

• 4 different weighing containers, for receiving the<br />

dispensed liquid on the balance pan during calibration,<br />

• 3 reservoirs used to hold the distilled water during the<br />

calibration procedure,<br />

• filters,<br />

• tweezers,<br />

• and a User’s Guide, suitable for the gravimetric method<br />

according to ISO 8655 standard.<br />

*Service offer listed above and offered by Gilson may<br />

differ country by country. Please contact your local<br />

distributor for details.<br />

Pipetman® P<br />

Service Pack *<br />

Pipetman Service pack* includes a Pipetman P pipette with<br />

a two year service offer. No paperwork, no time is wasted<br />

waiting for estimates or purchase order numbers. Just return<br />

the coupon with your pipette to your local Gilson Distributor<br />

to maintain your pipette performance at an economical<br />

price. In every Pipetman P Service Pack, you get the<br />

pipetting standard along with Gilson’s service expertise<br />

for two years. Each Service Pack contains:<br />

• One Pipetman P pipette, accessories and<br />

User’s Guide.<br />

• Coupon for FREE service in the FIRST year<br />

after purchase.<br />

• Coupon for half-price servicing in the<br />

second year.<br />

• Extended two-year<br />

warranty from the date<br />

of purchase<br />

*Not available in all countries.<br />

Please contact your local Gilson<br />

distributor for more information.<br />

Description<br />

Reference Number<br />

Weighing Kit<br />

F144700<br />

10 Filters for Weighing Kit F123854<br />

Description<br />

Reference Number<br />

Pipetman Service Pack P2<br />

F144803<br />

Pipetman Service Pack P10<br />

F144804<br />

Pipetman Service Pack P20<br />

F123610<br />

Pipetman Service Pack P100<br />

F123625<br />

Pipetman Service Pack P200<br />

F123611<br />

Pipetman Service Pack P1000<br />

F123612<br />

Pipetman Service Pack P5000<br />

F123613<br />

Pipetman Service Pack P10ml<br />

F161203<br />

46<br />

<strong>Manual</strong> <strong>Liquid</strong> <strong>Handling</strong> Catalog 2007 / January - More information available at www.gilson.com


Product Steel PET Nitril EPDM LCP PA PBT PC PE PVDF TPX POM PP<br />

Acetamide ++ N/A ++ ++ N/A ++ N/A N/A ++ N/A N/A ++ ++<br />

Ethyl acetate ++ + - ++ ++ ++ ++ ++ ++ ++ + N/A ++<br />

Acetone ++ + - ++ ++ ++ ++ - ++ ++ + + ++<br />

Acetonitrile ++ N/A + ++ + N/A N/A - ++ + N/A N/A ++<br />

Acetic acid 20% ++ ++ + ++ ++ ++ N/A ++ ++ ++ ++ ++ ++<br />

50% ++ ++ + ++ ++ - N/A + ++ ++ ++ ++ ++<br />

100% ++ ++ - ++ + - N/A - ++ ++ + + ++<br />

Hydrochloric acid 10% - ++ ++ ++ ++ - ++ ++ ++ ++ ++ ++ ++<br />

20% - + + ++ ++ - + ++ ++ ++ ++ + ++<br />

37% - - - ++ ++ - - + ++ ++ ++ - ++<br />

Hydrofluoric acid 20% + + - ++ + - + ++ ++ ++ ++ + ++<br />

40% - + - ++ - - - + ++ ++ ++ + ++<br />

Formic acid 100% ++ N/A - ++ ++ - + - ++ ++ N/A + ++<br />

Nitric acid 10% ++ ++ + ++ ++ - ++ ++ ++ ++ ++ + ++<br />

30% ++ + - + ++ - + ++ ++ ++ ++ - +<br />

65% ++ - - - + - - + + + ++ - -<br />

Phosphoric acid 20% ++ N/A + ++ N/A - ++ ++ ++ ++ ++ + ++<br />

85% ++ N/A - ++ N/A - ++ ++ ++ ++ ++ - ++<br />

Propionic acid 50% ++ - + N/A N/A ++ ++ + ++ ++ N/A - ++<br />

100% ++ - - N/A N/A + ++ - ++ ++ N/A - ++<br />

Sulfuric acid 20% ++ ++ + + ++ + ++ ++ ++ ++ ++ + ++<br />

50% ++ ++ - + ++ - + ++ ++ ++ ++ - ++<br />

95% ++ + - - - - - + + + ++ - +<br />

Trifluoroacetic acid 20% ++ N/A - N/A N/A + N/A ++ ++ ++ N/A ++ ++<br />

80% ++ N/A - N/A N/A - N/A + ++ ++ N/A + ++<br />

100% ++ N/A - N/A N/A - N/A - ++ ++ N/A - ++<br />

Benzyl alcohol ++ ++ - N/A N/A + N/A - ++ ++ ++ - ++<br />

Aniline ++ - + ++ N/A ++ N/A - + ++ N/A + ++<br />

Butanol / Butyl alcohol ++ ++ ++ ++ N/A ++ ++ ++ ++ ++ N/A ++ ++<br />

Chloroform ++ - - - N/A + - - + ++ + + -<br />

Cyclohexane ++ ++ ++ - N/A ++ N/A ++ ++ - + ++ +<br />

Diacetone alcohol ++ ++ + N/A N/A N/A N/A N/A N/A + N/A N/A ++<br />

Methylene chloride ++ + - - N/A - - - + ++ ++ ++ +<br />

Diethylene glycol ++ N/A ++ ++ ++ N/A N/A N/A ++ ++ ++ ++ ++<br />

Dimethylformamide (DMF) ++ ++ - + ++ ++ ++ - ++ - ++ ++ ++<br />

Dimethylsulfoxide (DMSO) ++ N/A - N/A N/A + N/A - ++ N/A N/A N/A N/A<br />

Dioxane (1,4) ++ ++ - + N/A ++ ++ - ++ + N/A ++ +<br />

Ethanol ++ ++ ++ ++ ++ ++ ++ ++ ++ ++ ++ ++ ++<br />

Ether ++ ++ ++ + N/A ++ ++ ++ + ++ + ++ ++<br />

Formaldehyde ++ ++ ++ ++ N/A ++ N/A ++ ++ ++ ++ ++ ++<br />

Hexane ++ N/A ++ - + ++ ++ ++ + ++ + ++ ++<br />

Hydrogen peroxide 50% ++ N/A + ++ N/A ++ ++ ++ ++ ++ ++ ++ ++<br />

Ammonium hydroxide 20% ++ ++ ++ ++ N/A N/A + - ++ N/A ++ ++ ++<br />

Sodium hydroxide 10% ++ + ++ ++ ++ ++ + - ++ ++ ++ ++ ++<br />

40% ++ - + ++ ++ ++ + - ++ ++ ++ ++ ++<br />

Sodium hypochlorite 15% Cl + N/A + ++ ++ ++ ++ ++ ++ ++ ++ - +<br />

Methanol ++ ++ ++ ++ + ++ ++ + ++ ++ ++ ++ ++<br />

Methyl ethyl ketone ++ ++ - + ++ ++ ++ - ++ - + + ++<br />

Pentane ++ N/A ++ - N/A N/A N/A ++ ++ ++ + ++ N/A<br />

Tetrahydrofuran (TH-) ++ ++ + + + ++ + - - + + N/A +<br />

Urea ++ ++ N/A N/A - ++ ++ N/A ++ ++ N/A ++ ++<br />

PET = Polyethylene Terephthalate<br />

Nitril = Nitril<br />

EPDM = Ethylene Propylene<br />

LCP = <strong>Liquid</strong> Cristal Polymer<br />

PA = Polyamide<br />

PBT = Polybutylene Terephthalate<br />

PC = Polycarbonate<br />

PE = Polyethylene<br />

PVDF = Polyvinylidene fluoride<br />

TPX = Polymethylpentene<br />

POM = Polyoxymethylene<br />

PP = Polypropylene<br />

++ No chemical degradation<br />

+ Medium resistance<br />

to chemical agents<br />

- Low resistance<br />

to chemical agents<br />

N/A No data available<br />

Chemical compatibility table<br />

47


Distributed by<br />

Mexico<br />

USA<br />

Canada<br />

Ecuador<br />

Colombia<br />

Peru<br />

Venezuela<br />

Guyana<br />

Chili<br />

Bolivia<br />

Guadeloupe<br />

Martinique<br />

Argentina<br />

Brazil<br />

Uruguay<br />

1 Austria<br />

14<br />

10<br />

2 Belgium<br />

26 8<br />

3 Bosnia and Herzegovina<br />

7<br />

4 Bulgaria<br />

18 19<br />

15 21<br />

Belarus<br />

31<br />

23<br />

5 Czech Republic<br />

2 12<br />

6 Croatia<br />

17<br />

1 5 9<br />

13 25 32<br />

30<br />

7 Denmark<br />

27 29<br />

16 6 24<br />

3<br />

8 Estonia<br />

20 4<br />

22 28<br />

9 France<br />

11 Turkey<br />

10 Finland<br />

Cyprus<br />

Tunis Malta<br />

Kuwait<br />

11 Greece<br />

Morocco<br />

Israel<br />

Jordan Bahrain Pakistan<br />

12 Germany<br />

Qatar<br />

13 Hungary<br />

Egypt<br />

14 Iceland<br />

Saudia UAE<br />

Oman<br />

15 Ireland<br />

Arabia<br />

16 Italy<br />

17 Luxembourg<br />

Senegal<br />

18 Lithuania<br />

19 Latvia<br />

Nigeria<br />

20 Macedonia<br />

Cameroon<br />

21 Netherlands<br />

Kenya<br />

22 Portugal<br />

23 Poland<br />

Tanzania<br />

24 Romania<br />

25 Slovakia<br />

26 Sweden<br />

27 Slovenia<br />

Iles Maurice<br />

28 Spain<br />

Reunion<br />

29 Serbia & Montenegro<br />

30 Switzerland<br />

31 United Kingdom<br />

South Africa<br />

32 Ukraine<br />

India<br />

Russia<br />

China<br />

Thailand<br />

South<br />

Korea<br />

Taiwan<br />

Hong kong<br />

Vietnam<br />

Malaysia<br />

Singapore<br />

Indonesia<br />

Japon<br />

Australia<br />

New Caledonia<br />

New Zealand<br />

www.gilson.com I sales@gilson.com I service@gilson.com I training@gilson.com<br />

Gilson, Inc. World Headquarters I 3000 Parmenter Street I P.O. Box 620027 I Middleton, WI 53562-0027 USA<br />

Tel: (1) 800-445-7661 or (1) 608-836-1551 I Fax: (1) 608-831-4451<br />

Gilson S.A.S. I 19, avenue des Entrepreneurs I BP 145, F-95400 Villiers-le-Bel, France<br />

Tel: (33-1) 34 29 50 00 I Fax: (33-1) 34 29 50 20<br />

LT800486E - © 2007 Gilson S.A.S. - All rights reserved - Printed in France, January 2007.<br />

Specifications subject to change without notice. Gilson, Inc. and Gilson S.A.S are ISO 9001 certified.<br />

oxygenemultimedia.fr

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!