Appendix E – Report Formats: Format Description<br />

Exercise Final Report Names<br />

Report Name<br />

Summary Report<br />

Tabular Report<br />

Selected Medians Report<br />

Trends and Medians<br />

Median Report<br />

Trend Reports<br />

ST/HR Loops Report<br />

ST/HR Slope Report<br />

Description<br />

One page overview of test with <strong>Resting</strong> and Max ST or peak median morphologies. For Maximal ST Depression, report only<br />

prints when a minimum of -.5 mm of ST depression occurs in one of the following leads. I, II, III, aVF, V2-V6. (V1, aVR, aVL<br />

excluded. For elevation, - aVR is excluded).<br />

Tabular summary of test by stage including time, speed, grade, workload, MET level, heart rate, blood pressure, RPP and<br />

comments.<br />

Records median morphologies at Baseline, Maximum ST Depression, Peak Exercise and Test End for 12 leads. For<br />

Maximum ST medians, column only prints when a minimum of -.5 mm of ST depression occurs in one of the following leads.<br />

I, II, III, aVF, V2-V6. (V1, aVR, aVL excluded. For elevation, - aVR is excluded).<br />

Records a plot of the heart rate and blood pressure against time. Next to these trend graphs are channels of stored median<br />

data from the various stages of an exercise test.<br />

Records median morphologies for 3, 6 or 12 leads. The 3 and 6 lead reports are configured using the ’Swedish format<br />

rhythm leads’ of the Exercise Setups (Report Leads). The 12 lead report uses the standard 12 lead set. The median storage<br />

intervals (also referred to as sample cardiac cycles) can be configured using the Median (First and Repeat) column of the<br />

Protocol Editor.<br />

Records plots of PVCs, heart rate and blood pressure. Also produces trend report of ST level and slope vs. time. The 3-lead<br />

trend report will use the first three leads of the ‘Swedish format rhythm leads’.<br />

A two-dimensional representation of ST Level vs. Heart Rate.<br />

Records linear regression of heart rate-adjusted slope for all leads, plus median morphology of lead with highest slope.<br />