Appendix E – Report Formats: Format Description<br />

Additional Report Names<br />

Report Name<br />

Description<br />

12 Rhythm Leads 10 seconds of 12-lead rhythm.<br />

Autorhythm<br />

10 seconds of 3, 6, or 12 leads of rhythm.<br />

CGR<br />

One median complex for each of the 12 leads combined with 10 seconds of 3-lead rhythm.<br />

Expanded Median Each median complex can be expanded by double the speed and double the gain.<br />

Linked Median<br />

A 4 x 2.5 with 1 rhythm lead format. Each lead begins with a median waveform and is followed by real-time data. The<br />

rhythm lead printed across the bottom of the report is the first lead of the ’Swedish format rhythm leads’ group that is<br />

configured in Exercise Setups (Report Leads).<br />

Medians and Rhythm A median complex for each of the standard 12 leads is displayed in the upper portion of this report. Below the medians are<br />

three rhythm strips. These rhythm leads are the first three leads of the ’Swedish format rhythm leads’ group that is<br />

configured in Exercise Setups (Report Leads).<br />

6 Lead Comparative<br />

Medians and Rhythm<br />

12 Lead Comparative<br />

Medians and Rhythm<br />

Hi-Res or PHi-Res Signal<br />

Averaged Template<br />

Hi-Res or PHi-Res Signal<br />

Averaged Standard<br />

Hi-Res or PHi-Res Signal<br />

Averaged Expanded<br />

ACI-TIPI<br />

The baseline and current medians are compared side-by-side and followed by real-time waveforms. The 6 leads used by<br />

this report are the ’Swedish format rhythm leads’ group that is configured in Exercise Setups (Report Leads).<br />

A one-page report for which the baseline and current medians are compared side-by-side and followed by 2.5 seconds of<br />

real-time rhythm for the standard 12 leads. ST level and ST slope are reported for each lead.<br />

Dominant (averaged) beat type.<br />

Vector magnitudes of X,Y,Z.<br />

400mm/s of expanded X,Y,Z medians and a RMS voltage function/VM plot.<br />

The analysis of the acquired <strong>ECG</strong> data appears at the top of the report.<br />