Operating Instructions - Jaken Medical...
Operating Instructions - Jaken Medical...
Operating Instructions - Jaken Medical...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Chapter<br />
8 Sending and Receiving Records<br />
NOTE: Sending and receiving functions are available on<br />
Eclipse units equipped with SCP-ECG capability. You may use<br />
a remote connection with either an internal or an external<br />
modem or a direct connection with another Eclipse or a<br />
compatible ECG management system.<br />
Eclipse 850 and Plus units with communication capabilities can receive<br />
requisitions, as well as transmit ECGs to and receive ECGs from other Eclipse<br />
electrocardiographs or the PYRAMIS ECG management system.<br />
How record status affects the sending operations<br />
NOTE:<br />
pg. 7-2.<br />
For the list of status codes, see ÒRecord StatusÓ on<br />
Record status affects whether records can be sent from the Eclipse. The<br />
following rules apply:<br />
l<br />
Records with status Dm can not be sent.<br />
l Records with status Rv can not be sent.<br />
In general, the following records will automatically be sent when BATCH<br />
SEND ECGS is selected in the DIRECTORY menu: records with the status<br />
ECG; records with the status ECG and Pr; records with the status RtE; and<br />
records with the status RtE and Pr. The following rules also apply:<br />
l<br />
l<br />
Records with status St or Rq will not be sent when BATCH SEND<br />
ECGS is selected in the DIRECTORY menu. These records may be<br />
sent individually from the Single ECG Functions list.<br />
Records with status, No, will not be sent when BATCH SEND<br />
ECGS is selected in the DIRECTORY menu. These records may be<br />
sent individually from the Single ECG Functions list.<br />
Changing Record Status<br />
Patient records can be marked so that they are automatically sent when<br />
BATCH SEND ECGS is selected in the DIRECTORY menu. Similarly, patient<br />
record status can be changed to ensure that a record is not sent.<br />
Mark Record as “SEND”<br />
To ensure that a record is sent the next time BATCH SEND ECGS is selected,<br />
select the MARK RECORD AS ÒSENDÓ from the Single ECG Functions list.<br />
1. Follow the instructions for accessing the list of patient Þles (see<br />
ÒUsing the DIRECTORY MenuÓ on pg. 7-1).<br />
Eclipse <strong>Operating</strong> <strong>Instructions</strong> 8-1