<strong>iMC</strong>-P – <strong>Operating</strong> <strong>Instruction</strong><br />

Spindle - 115/230V output, 3-poles<br />

Use this output connector to directly tap a working spindle without speed control. Use<br />

the delivered mating connector. Maximum load of the relay output is 230 V AC / 6A.<br />

AC-Input - net input module 115/230 VAC, 50 - 60 Hz<br />

The net input module consists of net input socket, net filter, fuse holder and net main<br />

switch. Connect the controller via delivered net cable to a free receptacle. After that<br />

you can switch on the controller with the net main switch.<br />

RS232 (PC) – programming interface<br />

Communication between <strong>iMC</strong>-P and control PC is realized via a serial interface<br />

(RS232). Use the delivered communication (null modem) cable for connection.<br />

A software protocol realizes the faultless transmission of the ASCII characters.<br />

Therefore it’s necessary that both systems respect the communication protocol:<br />

The connected control PC sends a command which ends with a line end<br />

character [CR, char (13)].<br />

The processor unit quits the execution or storing of a command with the<br />

quitting signal 0[char (48)] or returns an occurred error with an ASCII character<br />

unequal 0.<br />

Data transfer parameters:<br />

- 19200 baud<br />

- 8 data bits<br />

- 1 stop bit<br />

- no parity<br />