<strong>iMC</strong>-P – <strong>Operating</strong> <strong>Instruction</strong><br />
Spindle - 115/230V output, 3-poles<br />
Use this output connector to directly tap a working spindle without speed control. Use<br />
the delivered mating connector. Maximum load of the relay output is 230 V AC / 6A.<br />
AC-Input - net input module 115/230 VAC, 50 - 60 Hz<br />
The net input module consists of net input socket, net filter, fuse holder and net main<br />
switch. Connect the controller via delivered net cable to a free receptacle. After that<br />
you can switch on the controller with the net main switch.<br />
RS232 (PC) – programming interface<br />
Communication between <strong>iMC</strong>-P and control PC is realized via a serial interface<br />
(RS232). Use the delivered communication (null modem) cable for connection.<br />
A software protocol realizes the faultless transmission of the ASCII characters.<br />
Therefore it’s necessary that both systems respect the communication protocol:<br />
The connected control PC sends a command which ends with a line end<br />
character [CR, char (13)].<br />
The processor unit quits the execution or storing of a command with the<br />
quitting signal 0[char (48)] or returns an occurred error with an ASCII character<br />
unequal 0.<br />
Data transfer parameters:<br />
- 19200 baud<br />
- 8 data bits<br />
- 1 stop bit<br />
- no parity<br />