<strong>6100CR</strong> <strong>Refrigerated</strong> <strong>Sampler</strong><br />
Appendix B Material Safety Data Sheets<br />
H&S: 1,2-PROPANEDIOL 57-55-6 Page 4 of 7<br />
*PROPER SHIPPING NAME (IATA): Other regulated substances<br />
*UN/ID NUMBER: ID8027<br />
*HAZARD CLASS: 9 SUBSIDIARY RISK: None PACKING GROUP: None<br />
*LABELS REQUIRED: Miscellaneous<br />
*PACKAGING: PASSENGER: PKG. INSTR.: 906<br />
MAXIMUM QUANTITY: No limit<br />
CARGO : PKG. INSTR.: 906 MAXIMUM QUANTITY: No limit<br />
*SPECIAL PROVISIONS: None<br />
*USES:<br />
Organic synthesis, especially for polypropylene glycol and polyester<br />
resins; antifreeze solutions; solvent for fats, oils, waxes, resins,<br />
flavoring extracts, perfumes, colors, soft-drink syrups, and antioxidants;<br />
cellophane; hygroscopic agent; coolant in refrigeration systems;<br />
plasticizers, hydraulic fluids; bactericide; textile conditioners; in<br />
foods as a solvent, wetting agent and humectant; emulsifier; feed additive;<br />
anticaking agent; preservative (retards mold and fungi); cleansing<br />
creams; suntan lotions; pharmaceuticals; brake fluids; deicing fluids<br />
for airport runways; substitute for ethylene glycol and glycerol; fermentation<br />
inhibitor; as a mist to disinfect air; heat exchangers; as humectant<br />
in textiles, tobacco, and pet foods; and in veterinary medicine as<br />
a glucogenic (orally) in ruminants.<br />
*COMMENTS: Not available<br />
-HANDLING PROCEDURES<br />
===================<br />
*ACUTE/CHRONIC HAZARDS:<br />
This compound may be harmful by inhalation, ingestion or skin absorption<br />
[269]. It may cause irritation of the skin and eyes [042,058,269]. When<br />
heated to decomposition it emits toxic fumes of carbon monoxide and carbon<br />
dioxide [058,269]. It is a lacrimator [099,430].<br />
*MINIMUM PROTECTIVE CLOTHING: Not available<br />
*RECOMMENDED GLOVE MATERIALS:<br />
GlovES Expert System Recommended Gloves For Use With Neat (Undiluted) Chemical:<br />
This chemical has not been tested for permeation by Radian Corporation;<br />
however, the GlovES expert system was used to extrapolate permeation test<br />
information from compounds in the same chemical class and the following<br />
recommendation(s) are provided. The GlovES system uses permeation data from<br />
literature sources; therefore, extra safety margins should be used with the<br />
recommended exposure times. If this chemical comes into contact with your<br />
glove, or if a tear, puncture or hole develops, remove them at once.<br />
Suggested Glove Type Model Number Thickness Estimated Breakthrough<br />
PE/EVOH/PE Broste 4H Glove 0.07 mm 240 min.<br />
Natural rubber Pioneer 4-118 0.46 mm 480 min.<br />
Neoprene Edmont 29-840 0.38 mm 360 min.<br />
Nitrile Edmont 37-165 0.60 mm 360 min.<br />
*RECOMMENDED RESPIRATOR:<br />
When working with this chemical, wear a NIOSH-approved full face<br />
chemical cartride respirator equipped with the appropriate organic vapor<br />
cartridges. If that is not available, a half face respirator similarly<br />
equipped plus airtight goggles can be substituted. However, please note<br />
that half face respirators provide a substantially lower level of protection<br />
than do full face respirators.<br />
B-7