2150EX AV Flow Module - Isco
2150EX AV Flow Module - Isco
2150EX AV Flow Module - Isco
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>2150EX</strong> Area Velocity <strong>Flow</strong> System<br />
Section 5 Maintenance<br />
Measuring Input Voltage<br />
Input voltage can be monitored while you are connected to the<br />
<strong>2150EX</strong> with <strong>Flow</strong>link. The <strong>2150EX</strong> also can record input voltage<br />
readings.<br />
The <strong>Flow</strong>link voltage readings will drop lower when the batteries<br />
are nearly depleted. The chart in Figure 5-2 shows the noticeable<br />
voltage drop that starts to occur when the battery pack begins to<br />
discharge. Keep in mind that battery discharge rates vary widely<br />
depending on the your system’s operating environment.<br />
Input voltage can also be checked manually by disconnecting the<br />
<strong>2150EX</strong> module(s) from the 2191EX battery module and<br />
attaching the volt meter to the connector on top of the 2191EX.<br />
Check the battery packs individually, not as a pair.<br />
WARNING<br />
When using the above method to check voltage, use care<br />
not to short any pins.<br />
CAUTION<br />
Do not deep discharge the SLA2191EX battery packs, or you<br />
will reduce their cycle life. Battery life is improved by regularly<br />
scheduled recharging before a drop in voltage is indicated.<br />
Charging Batteries<br />
Charge the batteries only with <strong>Isco</strong>’s 8V2191SLA Lead-Acid<br />
Battery Charger, P/N 60-2004-343 (Figure 5-3). The maximum<br />
ambient temperature when charging is 50°C or 122°F. Never<br />
charge the battery packs in a hazardous atmosphere!<br />
WARNING<br />
Charge SLA2191EX battery packs only with the 8V2191SLA<br />
charger at an ambient temperature below 50°C (122°F), and<br />
never in a potentially explosive atmosphere.<br />
CAUTION<br />
Due to the self-discharge characteristics of this type of battery,<br />
it is imperative that the batteries be charged after 6 to 9<br />
months of storage to avoid possible permanent loss of capacity<br />
due to sulfation.<br />
5-5