<strong>2150EX</strong> Area Velocity <strong>Flow</strong> System<br />

Section 2 Preparation and Installation<br />

Observe intrinsic safety requirements regarding proximity to<br />

external sources of potential electric or magnetic interference.<br />

Refer to IEC 10079-14 section 12.2.2.5 on installation of cables<br />

and wiring.<br />

If the <strong>2150EX</strong> and <strong>AV</strong> <strong>2150EX</strong> sensor are not located in a potentially<br />

explosive atmosphere, the RS232EX isolator cable can be<br />

connected directly to the top of the <strong>2150EX</strong>.<br />

Label marking for the<br />

RS232EX Isolator<br />

Cable<br />

RATED INPUT<br />

25V 1/2A<br />

EIA-RS232<br />

connects to computer<br />

using maximum<br />

250V (Um =<br />

250V)<br />

Pin 2 Transmit Data<br />

Pin 3 Receive Data<br />

Pin 4 Requires 3 - 15V<br />

Pin 5 Power/Signal Ground<br />

Pin 7 Requires 3 - 15V<br />

Safe Area End<br />

5 4 3 2 1<br />

9 8 7 6<br />

Hazardous Area End<br />

Ui = 9.282V<br />

I i = 4.000A<br />

Pi = 4.000W<br />

Ci = 2.827uF<br />

Li = 0.000uH<br />

connects to an<br />

EX Network Cable<br />

(P/N 60-2004-336)<br />

Figure 2-19 RS232EX Isolator Cable for Connection to a Computer<br />

2.6.3 Connecting to a 2100<br />

Series Network Device<br />

The <strong>2150EX</strong> can be connected to a 2100 Series network device<br />

located in a safe area (with the exception of the 2102 Wireless<br />

module). In order for the <strong>2150EX</strong> to communicate with a 2100<br />

Series network device other than the 2194EX, the two must be<br />

connected by an <strong>Isco</strong> RS485EX Isolator Cable (P/N 60-2004-340).<br />

The hazardous area end, labeled with proper entity parameters,<br />

connects to the EX Network cable.<br />

Observe intrinsic safety requirements regarding proximity to<br />

external sources of potential electric or magnetic interference.<br />

Refer to IEC 10079-14 section 12.2.2.5 on installation of cables<br />

and wiring.<br />

If the <strong>2150EX</strong> and <strong>AV</strong><strong>2150EX</strong> sensor are not located in a potentially<br />

explosive atmosphere, the RS485EX isolator cable can be<br />

connected directly to the top of the <strong>2150EX</strong>.<br />

A site example using the Field Wizard is shown in Figure 2-2.<br />

2-26