<strong>2150EX</strong> Area Velocity <strong>Flow</strong> System<br />

Section 2 Preparation and Installation<br />

2.3 Site Examples Figures 2-1, 2-2, and 2-3 illustrate typical round-pipe sites. Key<br />

items are called out in the illustration and explained below.<br />

Figures 2-1 and 2-2 represent portable installations. For<br />

details about portable installations, see Section 2.4.<br />

Figure 2-3 represents a permanent installation. For details<br />

about permanent installations, see Section 2.5.<br />

The computer running <strong>Flow</strong>link (Figures 2-1 and 2-3) or the<br />

2101 Field Wizard module (Figure 2-2) should be located<br />

outside the potentially explosive atmosphere. The computer and<br />

modules communicate with the <strong>2150EX</strong> module.<br />

The <strong>2150EX</strong> area velocity flow module measures and stores<br />

the stream data. In portable installations (Figures 2-1 and 2-2),<br />

it is attached to a 2191EX or 2196EX battery module, which<br />

supplies power to the module.<br />

As described in Section 2.6.1, the EX network cable connects to<br />

the top of the <strong>2150EX</strong> stack and extends to the interface of the<br />

safe and hazardous areas.<br />

As described in Section 2.6.2, an RS232EX isolator cable connects<br />

the computer and the site. The cable supports the data<br />

transfers between the two, and is connected to an EX Network<br />

Cable connected to the top of the <strong>2150EX</strong> module.<br />

As described in Section 2.6.3, an RS485EX isolator cable connects<br />

the site with a Field Wizard or other network device. The<br />

cable supports the data transfers between the two, and is connected<br />

to an EX Network Cable, connected to the top of the<br />

<strong>2150EX</strong> module.<br />

In permanent installations (Figure 2-3), the <strong>2150EX</strong> is connected<br />

via network interface cable CA75EX-CTL (75m) or<br />

CA150EX-CTL (150m), usually through conduit, to the 2194EX<br />

network module, located in the safe area, which serves as both<br />

power supply and network or PC connection.<br />

The <strong>AV</strong><strong>2150EX</strong> sensor cable must be routed carefully without<br />

kinks, coils, or sharp bends, and secured in place without overtightening<br />

the plastic ties. Any excess cable must be kept out of<br />

the channel to prevent accumulation of debris.<br />

The Mounting Ring holds the <strong>AV</strong><strong>2150EX</strong> sensor in place.<br />

The <strong>AV</strong><strong>2150EX</strong> sensor is positioned in the flow stream to<br />

measure liquid level and velocity.<br />

Note<br />

For a complete listing of part numbers and ordering information,<br />

see Appendix B Accessories.<br />