<strong>2150EX</strong> Area Velocity <strong>Flow</strong> System<br />

Section 1 Introduction<br />

Table 1-5 Technical Specifications – <strong>2150EX</strong> and 2191EX <strong>Module</strong>s<br />

(Zones 0, 1, and 2)<br />

Size (HWD)<br />

<strong>2150EX</strong> connected to 2191EX 22.6 28.0 19.3 cm 8.9 11.0 7.6 in.<br />

Weight<br />

(without batteries)<br />

(with lithium battery packs)<br />

(with lead-acid battery packs)<br />

Material<br />

3.00 kg 6.6 lb<br />

4.20 kg 9.2 lb<br />

7.10 kg 15.7 lb<br />

ABS plastic, stainless steel<br />

Enclosure (self-certified) NEMA 4X, 6P IP 68<br />

Power<br />

Typical Battery Life (estimated)<br />

(assumes 23°C; actual<br />

performance is affected by<br />

site conditions)<br />

Temperature<br />

Operating and Storage<br />

Surface Temperature<br />

Operating Atmospheric Pressure<br />

Program Memory<br />

<strong>Flow</strong> Rate Conversions<br />

Level-to-Area Conversions<br />

Channel Shapes<br />

Data Points<br />

Level-to-<strong>Flow</strong> Rate Conversions<br />

Weirs<br />

Flumes<br />

Manning Formula<br />

Data Points<br />

Equation<br />

Total <strong>Flow</strong> Calculations<br />

Data Storage Memory<br />

Capacity<br />

Data Types<br />

Storage Mode<br />

Storage Interval<br />

7.0 to 9.1 VDC, 120 mA typical at 8 VDC, 1 mA standby<br />

Level Velocity LTC2191EX SLA2191EX<br />

Data Storage Interval Lithium Batteries Rechargeable Lead-Acid Batteries<br />

15 minutes 49 months 157 days<br />

5 minutes 21 months 64 days<br />

2 minutes 8 months 31 days<br />

1 minute 4 months 18 days<br />

-40° to 60°C -40° to 140°F<br />

(lead-acid battery packs have an operating temperature of -20° to 60°C or -4° to 140°F)<br />

Maximum 135 °C / 275 °F; N. American/European classification of T4<br />

80 to 110 kPa (0.8 to 1.1 bar)<br />

Non-volatile, programmable flash; can be updated using PC without opening<br />

enclosure or entering hazardous area; retains user program after updating<br />

Up to 2 independent level-to-area and/or level-to-flow rate conversions<br />

Round, U-shaped, rectangular, trapezoidal, elliptical, with silt correction<br />

Up to 50 level-area points<br />

V-notch, rectangular, Cipolletti, <strong>Isco</strong> <strong>Flow</strong> Metering Inserts, Thel-Mar<br />

Parshall, Palmer-Bowlus, Leopold-Lagco, trapezoidal, H, HS, HL<br />

Round, U-shaped, rectangular, trapezoidal<br />

Up to 50 level-flow rate points<br />

2-term polynomial<br />

Up to 2 independent, net, positive or negative, based on either flow rate conversion<br />

Non-volatile flash; retains stored data during program updates<br />

395,000 bytes (up to 79,000 readings, equal to over 270 days of level and velocity<br />

readings at 15 minute intervals, plus total flow and input voltage readings at 24<br />

hour intervals). Bytes per reading is 5.<br />

Level, velocity, flow rate 1, flow rate 2, total flow 1, total flow 2, input voltage<br />

Rollover with variable rate data storage based on level, velocity, flow rate 1, flow<br />

rate 2, total flow 1, total flow 2, or input voltage<br />

15 or 30 seconds; 1, 2, 5, 15 or 30 minutes; or 1, 2, 4, 12 or 24 hours<br />

1-8