07.03.2014 Views

2150EX AV Flow Module - Isco

2150EX AV Flow Module - Isco

2150EX AV Flow Module - Isco

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>2150EX</strong> Area Velocity <strong>Flow</strong> System<br />

Section 1 Introduction<br />

1.1 Product Description The <strong>2150EX</strong> Area Velocity <strong>Flow</strong> <strong>Module</strong> is part of <strong>Isco</strong>’s 2100<br />

Series. The 2100 Series measures parameters of open channel<br />

flow streams.<br />

The intrinsically safe <strong>2150EX</strong> is intended for use in potentially<br />

explosive atmospheres, and complies with ATEX Directive<br />

94/9/EC. The <strong>2150EX</strong> is Group II, Category 1G or 2G equipment<br />

as appropriate for use in Hazardous Zones 0, 1, and 2.<br />

The purpose of intrinsic safety is to limit the energy available to<br />

a given circuit or device to a level where electrical discharge<br />

(sparking) cannot ignite the hazardous (flammable or explosive)<br />

atmosphere. With no spark ignition possible, safe operation of<br />

the equipment in areas with potentially explosive atmospheres is<br />

possible.<br />

The standard 2100 Series is designed to be modular so that you<br />

can expand the system by stacking modules to meet your data<br />

collection needs. The <strong>2150EX</strong> incorporates this modularity,<br />

allowing up to two <strong>2150EX</strong> modules to be stacked on one 2191EX<br />

or 2196EX battery module.<br />

The <strong>2150EX</strong> is paired with <strong>Isco</strong>’s <strong>Flow</strong>link software. With this<br />

full-featured application software, you can quickly set up the<br />

module, retrieve measurement data, manage the sites, and<br />

analyze the data, and update the module’s own software, all<br />

without entering the hazardous area.<br />

The module’s data storage memory is quite flexible, able to store<br />

the measurements in intervals from 15 seconds to 24 hours. The<br />

module can also be configured for variable rate data storage.<br />

Variable rates allow you to store data at a different interval<br />

when a programmed condition occurs.<br />

The module’s program and collected data are stored in flash<br />

memory for security. Flash memory retains data without the<br />

concern of power failures or aging backup batteries. Its capacity<br />

is more than sufficient for most applications. The data storage<br />

memory can hold approximately 79,000 readings – the equivalent<br />

of nine months of level and velocity data when stored at<br />

fifteen minute intervals. The flash memory also stores sensor<br />

level adjustment information. A separate flash memory device<br />

inside the module stores the operating firmware.<br />

The rugged <strong>2150EX</strong> components are rated NEMA 4X, 6P (IP68).<br />

The permanently sealed enclosures are designed to meet the<br />

environmental demands of many sewer flow monitoring applications.<br />

All connections between sensors and communication cables<br />

“lock” in place. Each locking mechanism strongly secures the<br />

components and ensures a watertight seal.<br />

1-1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!