<strong>2150EX</strong> Area Velocity <strong>Flow</strong> System<br />

Safety Information<br />

For example, the <strong>2150EX</strong> network port cannot have an input<br />

voltage greater than 9.282V. When you look at the label on the<br />

power source (in this case the 2191EX), you can see that the<br />

maximum output voltage is 9.282V. From this you know that you<br />

can safely connect the two, and will not be providing too much<br />

voltage to the <strong>2150EX</strong> unit.<br />

Note<br />

This information is not intended to fully explain entity parameters.<br />

Other publications should be referenced for more detailed<br />

explanations.<br />

Installation<br />

Repair and Maintenance<br />

Teledyne <strong>Isco</strong>, Inc.<br />

Technical Service Dept.<br />

P.O. Box 82531<br />

Lincoln, NE 68501 USA<br />

Phone: (800) 228-4373<br />

(402) 464-0231<br />

FAX: (402) 465-3085<br />

E-mail:<br />

<strong>Isco</strong>Service@teledyne.com<br />

Installation of the <strong>2150EX</strong> system is described in this manual.<br />

Typical round-pipe installations are shown in Figures 2-1 and<br />

2-2, and Appendix E provides information on general safety procedures<br />

for work in manholes and sewers.<br />

When the equipment is installed in accordance with the instructions<br />

in this manual, it will not be subjected to dangerous<br />

mechanical or thermal stresses. It should not be installed where<br />

it may be attacked by existing or foreseeable aggressive substances<br />

that could damage the module enclosures. The enclosures<br />

are made of Acrylonitrile Butadiene Stytene (ABS) plastic.<br />

Substances that may cause damage include organic solvents<br />

(ketones and esters, aromatic and chlorinated hydrocarbons),<br />

alcohols, hydrocarbons, fuels, and UV radiation.<br />

Refer to Section 5 of this manual for instructions regarding<br />

periodic maintenance of the <strong>2150EX</strong> and its components.<br />

The internal components of the <strong>2150EX</strong> System are not user-serviceable.<br />

The case is completely sealed to protect the internal<br />

components. If you think your module requires repair, contact<br />

Teledyne <strong>Isco</strong>’s Technical Service Department.<br />

Rapidly failing desiccant may indicate a crack.<br />

WARNING<br />

Any cracks in the module case will impair the safety<br />

protection. If this occurs, return the unit to Teledyne <strong>Isco</strong><br />

for a replacement.<br />

Components of the <strong>AV</strong><strong>2150EX</strong> Sensor are encapsulated in plastic<br />

resin and are not user-serviceable. If any part of the <strong>AV</strong> Sensor<br />

fails, it must be replaced.<br />