<strong>Isco</strong> <strong>Flowlink</strong> <strong>5.1</strong> ® <strong>Software</strong><br />

Site Window - 2100<br />

11. TAP/SMS/SVR: Click the Set Alarm button and define<br />

the alarm condition or multiple conditions using the<br />

Equation Builder window.<br />

After entering the phone number information and defining<br />

condition, click Apply or press F9 to update the settings in the<br />

module.<br />

Server Alarms<br />

Analog Outputs<br />

The Server Alarms tab of the Server Options window is used to<br />

set up alarm notification if the <strong>Flowlink</strong> Server fails to receive<br />

pushed data from a site within a user-specified duration, or when<br />

a user-defined alarm condition is met. These server alarms are<br />

delivered as E-mail or SMS text messages.<br />

If you are using <strong>Isco</strong>’s 2108 Analog Output module, the Channel<br />

tabs on the Site window let you set up information for the analog<br />

output channels.<br />

Output Channel Name - Enter a name for the output channel.<br />

The output channel percentage and the measurement output<br />

value calculated by <strong>Flowlink</strong> will display below the channel<br />

name.<br />

Modify the Measurement Input for This Channel - Use the<br />

drop down list to select the input you want to measure (such as<br />

level or velocity). Indicate a minimum and maximum input range<br />

(minimum = 0% on analog output; maximum = 100%).<br />

Modify the Data Recording for This Channel - Use the<br />

Update Interval field to set how often the output channel is<br />

updated.<br />

<strong>Manual</strong> Control - The <strong>Manual</strong> Control button is used to<br />

temporarily override the channel’s output and is used when you<br />

are calibrating equipment. When you click the button, the<br />

<strong>Manual</strong> Control dialog box will appear. Set the output channel<br />

percentage by selecting one of the percentages displayed, or by<br />

selecting Custom and entering a percentage amount. Click the<br />

Set Output Channel Percentage button. The output will change<br />

to the manual setting; the dialog box will remain until you click<br />

Cancel. Then the output will revert to your previous settings.<br />

Power Control This tab of the Site window controls the On/off times for a 2102<br />

Wireless Communication Module or 2103/5 Cellular Modem<br />

Module.<br />

Set Wireless<br />

Schedule<br />

Rather than have the 2102 Wireless Module continually enabled,<br />

you can specify a time period for when the module is powered up.<br />

Type - Select the type of schedule you want: Specific, Weekly,<br />

Daily, or Mon-Fri. When you enter a Specific time period, the<br />

wireless will be activated only during that specified period.<br />

Weekly, Daily, or Mon-Fri time periods will be ongoing.<br />

Start/Stop - The Start and Stop display will vary, depending on<br />

what you selected for Type. For Specific, you will enter a Start<br />

66