<strong>Isco</strong> <strong>Flowlink</strong> <strong>5.1</strong> ® <strong>Software</strong><br />
Site Window - 2100<br />
• Set the measurement units by selecting an option from<br />
the pull-down list.<br />
• Set the rain volume per bucket tip.<br />
• Set Up Data Storage...<br />
• Diagnostics... - Downloads and displays a text file from<br />
the module. This file reports the performance of the<br />
module and rain gauge.<br />
• Hide in Measurements check box - when left unchecked,<br />
the Measurements tab displays this reading. If checked,<br />
the Measurements tab does not display this reading.<br />
If you have made any changes, click the Apply button to update<br />
the settings in the module.<br />
Sampler Control -<br />
2100 (2105)<br />
Sampler Enable<br />
Sampler Pacing<br />
The Sampler tab of the Site window displays the settings used by<br />
a 2105 Interface Module to control a connected sampler. The<br />
2105 can control two sampler functions - sampler enable and<br />
sampler pacing.<br />
The 2105 Interface Module can display this tab. From this tab<br />
you may:<br />
• View the Module and Measurement name.<br />
• View the sampler’s current Bottle Number and Enable<br />
Status.<br />
• Set Sampler Enable conditions.<br />
• Hide in Measurements check box - when left unchecked,<br />
the Measurements tab displays this reading. If checked,<br />
the Measurements tab does not display this reading.<br />
If you have made any changes, click the Apply button to update<br />
the settings in the module.<br />
Set up the sampler enable by choosing one of the three options in<br />
the Sampler Enable box:<br />
Always - the sampler remains enabled regardless of changing<br />
conditions.<br />
Never - the sampler remains disabled.<br />
On Trigger - The sampler is enabled when a user-defined<br />
condition is met. Select Latch to keep the sampler enabled after<br />
the condition is no longer true. The enabled state will continue<br />
until the Reset Latch button is pressed.<br />
From the Sampler Pacing box, select either None or Flow Paced.<br />
• None - The 2105 will not send flow pulses.<br />
• Flow Paced - paces the sampler at a rate proportional to<br />
the flow rate by using volume intervals. Use the Flow<br />
Pulse setting to set the interval.<br />