Site Window - 2100<br />

• Set up the total flow calculation:<br />

Input flow rate - select the flow rate to be used in the<br />

total flow calculation.<br />

Totalizer - select the type of total flow calculation:<br />

Net, Positive, or Negative.<br />

Resolution - shift the decimal point left or right to set<br />

the desired resolution.<br />

Update total flow every - the interval between total<br />

flow calculations.<br />

• Set Up Data Storage…<br />

• Diagnostics… - Downloads and displays a text file from<br />

the module. This file reports the performance of the<br />

module and its sensor. The measurement type will<br />

determine which information is included in this report.<br />

• Hide in Measurements check box - when left unchecked,<br />

the Measurements tab displays this reading. If checked,<br />

the Measurements tab hides this reading.<br />

If you have made any changes, click on the Apply button to<br />

update the settings in the module.<br />

Zero Total Flow<br />

Total Flow<br />

Diagnostics<br />

Rainfall - 2100<br />

(2105)<br />

Cumulative flow reported will eventually reach a maximum<br />

value, depending on the flow conversion method and units<br />

selected. At this point, the total flow will roll over, just as a car’s<br />

odometer would.<br />

The Zero Total Flow button allows you to reset the cumulative<br />

flow at known intervals so that more meaningful values can be<br />

represented by this field. It is also helpful to zero the total flow<br />

after moving the flow meter to a different site.<br />

After downloading the diagnostics from the module, <strong>Flowlink</strong><br />

displays the information in the Report window. This information<br />

can be useful when evaluating the module’s performance, or<br />

when troubleshooting a problem with the assistance of Teledyne<br />

<strong>Isco</strong>’s Technical Service Department.<br />

Total Flow Diagnostics presents limited information, typically:<br />

• Date and Time - the instrument’s date and time that the<br />

report was generated.<br />

• Any fault indication associated with the Total Flow<br />

Calculation.<br />

The Rainfall tab of the Site window is used to view or change<br />

rainfall measurement settings. Access this tab by clicking the<br />

“Rainfall” label on the Measurements tab.<br />

The 2105 Interface Module can display this tab. From this tab<br />

you may:<br />

• View the Module and Measurement name.<br />

• View the total rainfall since midnight.<br />

61