Site Window - 2100<br />
• View the Module and Measurement name.<br />
• View the current flow rate measurement.<br />
• Select a flow conversion method from a pull-down list.<br />
• Specify the Conversion type.<br />
• Enter the applicable parameters for the chosen<br />
conversion type.<br />
• From the Flow rate measurement dropdown list, set<br />
measurement units by selecting an option from the pulldown<br />
list.<br />
• If more than one instrument is configured to measure<br />
level, select the desired instrument from the Level Input<br />
dropdown list.<br />
• Set Up Data Storage…<br />
• Diagnostics… - Downloads and displays a text file from<br />
the module. This file reports the performance of the<br />
module.<br />
• Hide in Measurements check box - when left unchecked,<br />
the Measurements tab displays this reading. If checked,<br />
the Measurements tab hides this reading.<br />
If you have made changes to the settings on this tab, click on the<br />
Apply button to update the module.<br />
Flow Rate<br />
Diagnostics<br />
Total Flow - 2100<br />
After downloading the diagnostics from the module, <strong>Flowlink</strong><br />
displays the information in the Report window. This information<br />
can be useful when evaluating the module’s performance, or<br />
when troubleshooting a problem with the assistance of Teledyne<br />
<strong>Isco</strong>’s Technical Service Department.<br />
Flow Rate Diagnostics only presents limited information,<br />
typically:<br />
• Date and Time - the instrument’s date and time that the<br />
report was generated.<br />
• A line indicating that the module’s internal flow<br />
conversion is valid<br />
• The silt level, as entered on the Flow Conversion tab<br />
when using area velocity as the flow conversion method.<br />
• The calculated silt area.<br />
The Total Flow and Total Flow 2 tabs are used to view total flow<br />
settings for modules able to calculate total flows. Access this tab<br />
by clicking on the “Total Flow” labels on the Measurements tab.<br />
From this tab you may:<br />
• View the Module and Measurement name.<br />
• View the total flow measurement.<br />
• Set the measurement units by selecting an option from<br />
the pull-down list.<br />
• Zero the total flow. The “Zero Total Flow” button resets<br />
the cumulative flow.<br />
60