<strong>Isco</strong> <strong>Flowlink</strong> <strong>5.1</strong> ® <strong>Software</strong><br />

Site Window - 2100<br />

Velocity - 2100<br />

Zero Level Offset<br />

The Velocity tab of the Site window is used to view or change<br />

velocity measurement settings. Access this tab by clicking on the<br />

“Velocity” label on the Measurements tab.<br />

Modules able to read liquid velocities can display this tab. From<br />

this tab you may:<br />

• View the Module and Measurement name.<br />

• View the current Velocity measurement.<br />

• Set the measurement units by selecting an option from<br />

the pull-down list.<br />

• Enter a Zero level offset value.<br />

• Control how flow readings are recorded if the module is<br />

unable to measure velocity. Check the “Set flow rate to<br />

zero if no velocity data” to record the flow rate as “0.000”<br />

when the module is unable to take a velocity reading. If<br />

the check box is left blank, a no data code will be<br />

recorded instead.<br />

• Prevent interference from other velocity measurements.<br />

If the area velocity sensors of a multiple-module site are<br />

placed near each other, it is important that each sensor<br />

receives its own transmitted signal. Check this box when<br />

multiple area velocity sensors are located in the same<br />

channel so that the site will ensure only one velocity<br />

measurement is taken at a time. Leave this box<br />

unchecked for single-module sites or multiple module<br />

sites measuring velocities in separate channels.<br />

• Positive Velocities Only check box. Select this box to log<br />

only positive velocities; negative velocities (reversed<br />

flows) are stored as zero. To log both positive and<br />

negative velocities leave this box blank.<br />

• Set Up Data Storage…<br />

• Diagnostics… - Downloads and displays a text file from<br />

the module. This file reports the performance of the<br />

module and its sensor. The measurement type will<br />

determine which information is included in this report.<br />

• Hide in Measurements check box - when left unchecked,<br />

the Measurements tab displays this reading. If checked,<br />

the Measurements tab hides this reading.<br />

If you have made any changes, click on the Apply button to<br />

update the settings in the module.<br />

Area Velocity sensors are sometimes mounted higher on the side<br />

of the channel to avoid silting.<br />

• If the Area Velocity sensor is mounted on the side of the<br />

channel, enter the vertical distance from the bottom<br />

center of the channel. Refer to the instrument’s<br />

instruction manual to calculate this distance.<br />

• If the Area Velocity sensor is mounted at the bottom of<br />

the channel, simply set the Zero level offset to zero.<br />

58