07.03.2014 Views

Flowlink 5.1 Software Instruction Manual - Isco

Flowlink 5.1 Software Instruction Manual - Isco

Flowlink 5.1 Software Instruction Manual - Isco

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Isco</strong> <strong>Flowlink</strong> <strong>5.1</strong> ® <strong>Software</strong><br />

Site Window - 2100<br />

W (wait for dial tone)<br />

• TCP Address - (2100 equipped w/ CDMA modem) Enter<br />

the correct static IP or public domain address.<br />

To save changes to the communications settings, click Apply.<br />

Measurements -<br />

2100<br />

Data - 2100<br />

When connected, <strong>Flowlink</strong> continually polls the site for “realtime”<br />

readings. This tab of the Site window displays the realtime<br />

readings. The number of modules and active sensors at the<br />

site will determine which readings are displayed.<br />

The Measurements tab displays the input voltage for the system.<br />

This information will aid you in determining when battery<br />

powered instruments require service.<br />

To view the real-time readings highlight the module(s) and<br />

<strong>Flowlink</strong> displays the data on the Measurements tab.<br />

To view or set the properties of a specific reading type, click on<br />

the data label. <strong>Flowlink</strong> will then display the Measurement<br />

Properties tab.<br />

When <strong>Flowlink</strong> is disconnected from the site, the last valid<br />

measurement values are shown.<br />

View and manage data storage for 2100 series modules from the<br />

Data tab of the Site window.<br />

The top list box shows the Data Storage Name of each module.<br />

Each module reports:<br />

• Max Readings - The total number of readings that the<br />

module can store.<br />

• Utilization - Displays the amount of memory in use as a<br />

percentage.<br />

• Oldest Reading - The time stamp of the oldest reading<br />

held in the module’s memory.<br />

• Data Storage Fields - Reports how many of the<br />

available storage fields are in use.<br />

When you select (highlight) a Data Storage Name, <strong>Flowlink</strong><br />

shows detailed data storage information in the lower half of this<br />

tab.<br />

The bottom list box displays measurement-specific data storage<br />

information for the module highlighted in the upper box. Each<br />

measurement type that may be stored by the module is listed in<br />

this box. Each measurement reports:<br />

• Measurement - the name of the measurement data<br />

• Primary - the primary data storage rate.<br />

• Secondary - the secondary data storage rate.<br />

• Recent reading - the time/date of the most recent<br />

reading stored in the module.<br />

• Readings - the number of readings stored in the<br />

module’s memory.<br />

52

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!