<strong>Isco</strong> <strong>Flowlink</strong> <strong>5.1</strong> ® <strong>Software</strong><br />
Menu Commands<br />
• View Log File: Displays the iscolog.txt file, a record of<br />
scheduled events as they occur.<br />
• License: Opens the <strong>Flowlink</strong> License Activation wizard.<br />
Use this wizard when you need to renew or upgrade your<br />
<strong>Flowlink</strong> license.<br />
• Server Options: Opens the Server Options window to<br />
manage <strong>Flowlink</strong> Pro users and server alarms.<br />
Utilities Options<br />
Instrument<br />
Connection Options<br />
Default Connection<br />
Type<br />
Default to … check<br />
box<br />
Direct/Wireless<br />
Connect<br />
Selecting Utilities>Options from the menu displays the Options<br />
window. This window contains the default settings for <strong>Flowlink</strong>’s<br />
operation. The tabs in the Options window contain settings for<br />
the following:<br />
• 4100/4200/6700, 2100, Field Wizard, and Pulse Doppler<br />
• Default Units of Measurement<br />
• Graph Defaults<br />
• Miscellaneous<br />
You establish default communication settings in the<br />
Utilities>Options window. There are four tabs, “4100/4200/6700”,<br />
“2100,” “Field Wizard,” and “Pulse Doppler” that hold these<br />
defaults. <strong>Flowlink</strong> will use the settings on both tabs to assume<br />
the type of instrument to which it is connecting, and which<br />
method (direct, modem, wireless, or TCP) <strong>Flowlink</strong> is to use.<br />
Connection type options include Direct, Modem, Wireless, and<br />
TCP.<br />
• Select the Direct option when connecting to <strong>Isco</strong><br />
instruments through an interrogator cable,<br />
communications cable, or a short haul modem attached<br />
to your computer’s serial port.<br />
• Select the Modem option to connect to instruments<br />
through a telephone modem.<br />
• Select the Wireless option when using the 2102 Wireless<br />
Communication Module.<br />
• Select TCP for remote serial communication via static IP<br />
or public domain address with a 2100 module equipped<br />
with a CDMA modem, or a 6712 sampler equipped with a<br />
CDMA or GSM modem.<br />
Check this box on the instrument tab to direct <strong>Flowlink</strong><br />
to use the communication protocol that is compatible for<br />
the device type to which you are primarily connecting.<br />
For example, if you are primarily connecting to <strong>Isco</strong>’s<br />
2100 devices, check the “Default to 2100” box on the 2100<br />
tab.<br />
• Select the default Com port from the pull-down menu.<br />
Refer to your computer’s documentation for more<br />
information on Com ports.<br />