<strong>Isco</strong> <strong>Flowlink</strong> <strong>5.1</strong> ® <strong>Software</strong><br />

Menu Commands<br />

• View Log File: Displays the iscolog.txt file, a record of<br />

scheduled events as they occur.<br />

• License: Opens the <strong>Flowlink</strong> License Activation wizard.<br />

Use this wizard when you need to renew or upgrade your<br />

<strong>Flowlink</strong> license.<br />

• Server Options: Opens the Server Options window to<br />

manage <strong>Flowlink</strong> Pro users and server alarms.<br />

Utilities Options<br />

Instrument<br />

Connection Options<br />

Default Connection<br />

Type<br />

Default to … check<br />

box<br />

Direct/Wireless<br />

Connect<br />

Selecting Utilities>Options from the menu displays the Options<br />

window. This window contains the default settings for <strong>Flowlink</strong>’s<br />

operation. The tabs in the Options window contain settings for<br />

the following:<br />

• 4100/4200/6700, 2100, Field Wizard, and Pulse Doppler<br />

• Default Units of Measurement<br />

• Graph Defaults<br />

• Miscellaneous<br />

You establish default communication settings in the<br />

Utilities>Options window. There are four tabs, “4100/4200/6700”,<br />

“2100,” “Field Wizard,” and “Pulse Doppler” that hold these<br />

defaults. <strong>Flowlink</strong> will use the settings on both tabs to assume<br />

the type of instrument to which it is connecting, and which<br />

method (direct, modem, wireless, or TCP) <strong>Flowlink</strong> is to use.<br />

Connection type options include Direct, Modem, Wireless, and<br />

TCP.<br />

• Select the Direct option when connecting to <strong>Isco</strong><br />

instruments through an interrogator cable,<br />

communications cable, or a short haul modem attached<br />

to your computer’s serial port.<br />

• Select the Modem option to connect to instruments<br />

through a telephone modem.<br />

• Select the Wireless option when using the 2102 Wireless<br />

Communication Module.<br />

• Select TCP for remote serial communication via static IP<br />

or public domain address with a 2100 module equipped<br />

with a CDMA modem, or a 6712 sampler equipped with a<br />

CDMA or GSM modem.<br />

Check this box on the instrument tab to direct <strong>Flowlink</strong><br />

to use the communication protocol that is compatible for<br />

the device type to which you are primarily connecting.<br />

For example, if you are primarily connecting to <strong>Isco</strong>’s<br />

2100 devices, check the “Default to 2100” box on the 2100<br />

tab.<br />

• Select the default Com port from the pull-down menu.<br />

Refer to your computer’s documentation for more<br />

information on Com ports.<br />