<strong>Isco</strong> <strong>Flowlink</strong> <strong>5.1</strong> ® <strong>Software</strong><br />
Menu Commands<br />
haul modem attached to your computer’s serial port. Select<br />
“Modem” to connect to the instrument through a telephone<br />
modem. Select “Wireless” when using the 2102 Wireless<br />
Communication Module. Select “TCP” for serial communication<br />
with a cellular modem-equipped 2100 module or 6712 sampler<br />
via static IP or public domain address.<br />
Com Port - (Direct and Wireless) Select the Com Port from the<br />
pull-down list.<br />
Baud Rate - (Direct and Wireless) Select the Baud Rate from<br />
the pull-down list. A rate of 9600 is recommended for 4100/4200/<br />
6700 instruments when using Direct or Wireless.<br />
Select 38400 when direct connecting to 2100 and Pulse Doppler<br />
instruments, 19200 for wireless communication.<br />
Select 38400 when direct connecting to a 2101 Field Wizard.<br />
Modem - (Modem only) Select an installed modem on the<br />
computer from the pull-down list. <strong>Flowlink</strong> will only list those<br />
modems installed in Windows. <strong>Flowlink</strong> will use the selected<br />
Modem and its Windows settings (Com port, baud, etc.) to make<br />
the connection. If you need to change the modem settings, open<br />
the Modem Control Panel. (Windows Start>Settings>Control<br />
Panel.) A baud rate of 9600 is recommended for 4100/4200/6700<br />
instruments, 38400 for 2100 and Pulse Doppler instruments.<br />
• Select Default from the list to use the modem<br />
specified in Utilities>Options for the appropriate<br />
device type. This automatically selects the modem<br />
used for a specific site, from any computer.<br />
Phone number - (Modem only) Enter a phone number with or<br />
without dashes. This number can include the following<br />
commands:<br />
T (tone dial)<br />
, (pause)<br />
@ (wait for silence)<br />
W (wait for dial tone)<br />
TCP Address - (2100 w/ CDMA modem or 6712 w/ CDMA or<br />
GSM modem) Enter the correct static IP or public domain<br />
address.<br />
Use the Create new site check box when you do not want<br />
<strong>Flowlink</strong> to match the instrument to a site in the database. This<br />
is useful when you have relocated an instrument to a new site.<br />
<strong>Flowlink</strong> creates a new site, lets you rename it, allows you to<br />
delete all the data from the instrument, and adds the new site to<br />
the workspace.<br />
As a default setting, this window is displayed every time<br />
<strong>Flowlink</strong> is started. To disable this feature, leave the Show this<br />
dialog on startup check box (at the bottom of the dialogue box)<br />
blank.<br />