<strong>Isco</strong> <strong>Flowlink</strong> <strong>5.1</strong> ® <strong>Software</strong><br />

Editor Window<br />

Other Adjustment<br />

Methods<br />

Copy<br />

• Copy and Paste - Highlight correct readings and Copy<br />

(Ctrl-C) them. This places the readings on the clipboard.<br />

Highlight the incorrect data and Paste (Ctrl-V). <strong>Flowlink</strong><br />

replaces the readings with those on the clipboard. You<br />

can also copy and paste using the buttons on the toolbar<br />

or using the menu options displayed when you right-click<br />

in the editor window.<br />

• Cut - Highlight the readings to remove and Cut (Ctrl-X)<br />

them. This places them on the clipboard. They will be<br />

available for pasting elsewhere until they are replaced by<br />

another Copy or Cut. Cut can be used to remove<br />

unwanted readings or No Data codes from the data set.<br />

You can also cut readings with the Cut button on the<br />

toolbar.<br />

• Insert - Highlight the beginning point where you wish to<br />

insert readings. Then, right click and select<br />

Insert>Before or Insert>After. The editor then inserts<br />

data from the clipboard (from the last Copy or Cut).<br />

Insert may be used to fill gaps, or to add readings at the<br />

beginning or end of the data. It cannot overwrite valid<br />

readings.<br />

• Click and drag - Single readings can be moved on the<br />

graph by clicking and dragging the point to a new value.<br />

Notes:<br />

• It is possible to insert readings that will not appear in<br />

the timespan currently viewed on the graph and the<br />

table. It may be necessary to move to the previous or next<br />

time span to see the adjustments.<br />

• When <strong>Flowlink</strong> combines sites to form a line of data on a<br />

graph or report, it will not combine error codes with<br />

readings. Instead, it will report no data.<br />

• New values that you can store in the database are only<br />

limited to the resolution and significant digits for the<br />

data set. Viewing the Data set Properties (Highlight a<br />

data set in the workspace and press Ctrl+F2) will reveal<br />

this information.<br />

• When editing, <strong>Flowlink</strong> saves both the original and the<br />

edited data. If necessary, the original values can be<br />

restored.<br />

To copy readings displayed in the Editor window, first highlight<br />

the data to copy. Then, do one of the following:<br />

• click the Copy button on the toolbar<br />

• right-click and select Copy from the popup menu<br />

• press Ctrl-C on the keyboard.<br />

When you copy data, the data will be stored on a clipboard so<br />

that you can paste it elsewhere, including another data set (of<br />

the same measurement type) or application.<br />

135