<strong>Isco</strong> <strong>Flowlink</strong> <strong>5.1</strong> ® <strong>Software</strong><br />

Editor Window<br />

default timespan specified by the Utilities>Options<br />

settings.<br />

• Graph the data. Then right-click on the graph and<br />

select the Edit option to enable the Editor.<br />

Alternatively, you can click the Edit/View<br />

toolbar button to enable the editor. The Editor<br />

window displays the timespan specified by the graph<br />

properties.<br />

2. Locate the incorrect data and highlight it. Using default<br />

settings, <strong>Flowlink</strong> can edit up to 1439 readings (a day of<br />

readings at one-minute intervals) at a time. The number<br />

of readings can be increased or decreased as needed from<br />

the Utilities>Options window.<br />

3. Using the Type pull-down list on the Editor toolbar,<br />

Determine the type of reading adjustment that will be<br />

necessary.<br />

• Constant value - changes all of the highlighted<br />

readings to a single value.<br />

• Fixed offset - increases or decreases the highlighted<br />

readings by a fixed amount.<br />

• Proportional - distributes an adjustment<br />

proportionately over selected readings.<br />

• Multiply by Constant Value - multiplies the readings<br />

by a specified constant value. Specify a value greater<br />

than 1 to increase the readings; less than 1 to<br />

decrease the readings.<br />

• Auto Correct - When selected, <strong>Flowlink</strong> will adjust<br />

the highlighted readings to fit adjacent readings.<br />

Because the amount is calculated by <strong>Flowlink</strong>, the<br />

Amount value is not needed.<br />

• Time (minutes) - shifts the highlighted times forward<br />

or backward a fixed amount.<br />

• Restore to Original - removes any corrections made to<br />

the readings to restore it to the original data.<br />

4. Enter the Amount.<br />

5. Click Adjust. <strong>Flowlink</strong> changes the data according to the<br />

Type and Amount. The new readings are displayed on<br />

the table. The graph shows both the original and the new<br />

readings. Default line colors can be specified on the<br />

Utilities>Options window.<br />

6. Click Save Changes.<br />

Sometimes you may find that a combination of adjustment types<br />

may work best to produce the desired results. Repeat the steps<br />

above to apply additional adjustments.<br />