Flowlink 5.1 Software Instruction Manual - Isco
Flowlink 5.1 Software Instruction Manual - Isco
Flowlink 5.1 Software Instruction Manual - Isco
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Isco</strong> <strong>Flowlink</strong> <strong>5.1</strong> ® <strong>Software</strong><br />
Graph Window<br />
4. Click OK. The text appears next to the data point on the<br />
graph.<br />
Notes:<br />
• The Cancel button closes the Add Text window without<br />
placing an annotation on the graph.<br />
• To delete a text annotation from the graph, select the<br />
data point for the annotation. Then right-click and select<br />
the TextBox option from the popup menu which opens<br />
the Add Text Box window. Click the Delete button and<br />
<strong>Flowlink</strong> removes the annotation.<br />
• There is a limit of 15 text boxes to a time span, although<br />
more text boxes can be added elsewhere in the graph.<br />
Note that if the time span is increased and the number of<br />
text boxes exceeds the limit, the text boxes are hidden<br />
from the display.<br />
• Text boxes are saved with the Graph (.IGD) file, not as<br />
part of the site data. Be aware that if the graph is used as<br />
a template, the text boxes are retained when the<br />
substituted data is displayed.<br />
Best Fit Curves<br />
To aid the analysis of data represented in a scatter plot, the Best<br />
Fit Curves feature can apply a smooth curve to your data. This<br />
can help you determine if the data fits within an expected model.<br />
Additionally, best fit curves may be used when editing data in a<br />
scatter plot.<br />
To display a best fit curve on a scatter plot, open the graph<br />
properties window and select the “Generate best fit curve” check<br />
box on the General Properties tab.<br />
You can select from two types of best fit curves. A third degree<br />
polynomial curve can be applied using any data in series one and<br />
two. A Manning formula curve can also be applied to plot the<br />
level with a calculated velocity based on the pipe diameter,<br />
roughness coefficient and slope. The Manning formula option<br />
requires that series one use Level data for the Y-Axis and series<br />
two use Velocity data for the X-Axis. Select the check box for the<br />
desired option. If the Manning formula is selected, a window<br />
appears to enter coefficients for the formula.<br />
The best fit curve will be displayed with limits. Enter the limit<br />
value and specify the limit type. Limit type options are:<br />
• Percent of Best Fit Curve - <strong>Flowlink</strong> calculates upper<br />
and lower limit lines using the limit value as a<br />
percentage of each best fit curve data point.<br />
• Offset of Best Fit Curve - <strong>Flowlink</strong> calculates upper<br />
and lower limits using the limit value as a fixed offset for<br />
each best fit curve data point.<br />
• Percent of Maximum Value - <strong>Flowlink</strong> identifies the<br />
maximum value in the best fit curve and determines an<br />
offset value using the limit value as a percentage. Each<br />
127