<strong>Isco</strong> <strong>Flowlink</strong> <strong>5.1</strong> ® <strong>Software</strong><br />
Graph Window<br />
flow rate of 551.14 gpm would display as 551.1 with a<br />
resolution of 0.1 and 550 with a resolution of 10.)<br />
Operation<br />
Miscellaneous<br />
check boxes<br />
Use the operation pull-down list to apply mathematical<br />
operations to one or more data sets that appear on the list. You<br />
can choose from:<br />
• None - No operations will be applied to the series.<br />
• Series Formula - Add, subtract, multiply, and divide data<br />
sets, and/or raise quantities to a power (exponentiation).<br />
• Flow conversion - Convert level, or level and velocity data<br />
sets to a flow rate off-line.<br />
• Volume Conversion - Convert flow rate readings to a total<br />
volume.<br />
Only one operation can be performed in a series; more operations<br />
will require you to add a series for each operation. <strong>Flowlink</strong><br />
processes the operations in order (S1, S2, S3…). If the result of<br />
one operation is required in another, it must precede the<br />
dependent operation.<br />
• Display summary - If this box is checked, <strong>Flowlink</strong> will<br />
calculate and display a summary value for the series. If<br />
the series contains Total Flow or Rain data, <strong>Flowlink</strong><br />
calculates the sum of all points in the timespan. If this<br />
box is checked for data other than Total Flow or Rain,<br />
<strong>Flowlink</strong> calculates the average of all points in the<br />
timespan. Graphs display the summary in the legend<br />
above the graph; tables display the summary at the<br />
bottom of the column. If the series displays Flow Rate<br />
data, it is possible to change the units.<br />
• Display min/max times - (Tables only) Check this box<br />
to include the time of the minimum or maximum value<br />
generated by a series statistical function.<br />
• Display samples - Check this box to display events that<br />
accompany the readings in the site record. When<br />
displaying events across multiple panes, manual scaling<br />
may be necessary to control the placement of the events<br />
across each pane.<br />
• Visible - This box must be checked to plot the series on<br />
the graph. This does not affect tables.<br />
• Sample Event Position in Y-axis - If the selected<br />
series contains sample event data and the “Visible” box is<br />
checked, enter a percentage of the Y-axis height to specify<br />
the position of the sample event symbols in the pane.<br />
• Total Flow - If the selected series contains flow rate<br />
data, select this option to display the total flow for the<br />
displayed time span above the graph. Total flow will be<br />
reported on the graph using the units selected in the drop<br />
down list below this check box.<br />
118