07.03.2014 Views

Flowlink 5.1 Software Instruction Manual - Isco

Flowlink 5.1 Software Instruction Manual - Isco

Flowlink 5.1 Software Instruction Manual - Isco

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Isco</strong> <strong>Flowlink</strong> <strong>5.1</strong> ® <strong>Software</strong><br />

Site Window - 4100/4200/6700<br />

3. Enter at least four data points in the table. The table can<br />

hold a maximum of 50 data points. If you have copied<br />

data points from another table or spreadsheet, select the<br />

top-left cell and press Control-V on your keyboard to<br />

paste the data from the clipboard.<br />

Each data point requires two values:<br />

• Level to flow requires a flow stream level and the<br />

flow rate that corresponds to that measured level.<br />

• Level to area requires a flow stream level and the<br />

cross-sectional area of the channel at that level.<br />

4. Select OK when the set is complete.<br />

Note: The conversion accuracy between points increases with<br />

the number of points entered. Keep in mind that you are defining<br />

the entire channel shape mathematically; select points that best<br />

represent any curves or variations. Compound shapes will need<br />

many data points.<br />

Maximum level<br />

Sampler Control -<br />

4100/4200<br />

Sampler Enable<br />

<strong>Isco</strong> instruments that build an internal flow conversion table to<br />

convert readings to flow rates require a Maximum Level. For<br />

most standard primary devices, this is information available<br />

from the manufacturer.<br />

However, you should not arbitrarily enter a value such as the<br />

largest value from a primary device specification sheet. Instead,<br />

use a value that is somewhat above the highest expected level for<br />

your actual situation, even if that level is less than the published<br />

maximum for a given primary device. This will improve the<br />

resolution of the conversion table. For example, if the channel is<br />

six feet deep, but the stream level rarely exceeds four feet,<br />

resolution can be improved if the points within the table were<br />

scaled over four feet instead of six.<br />

Caution: If the actual depth exceeds the entered maximum<br />

level, flow rates will not be calculated for those levels above the<br />

entered maximum level. The indicated flow rate will peak when<br />

depth reaches the maximum level and remain there until actual<br />

depth drops below the entered maximum head.<br />

This tab of the Site window displays the settings that flow<br />

measurement instruments use to control a connected sampler.<br />

These flow measurement instruments can control two sampler<br />

functions - sampler enable and sampler pacing.<br />

Set up the sampler enable by choosing one of the three options in<br />

the When to Enable box.<br />

• Always - sets the sampler inhibit line to always enable<br />

the sampler.<br />

• Never - sets the sampler inhibit line to always disable the<br />

sampler.<br />

• On trigger - controls the sampler inhibit line with a userdefined<br />

condition.<br />

90