<strong>2102</strong> <strong>Wireless</strong> Communication <strong>Module</strong><br />

Section 2 Introduction<br />

2.4 Technical<br />

Specifications<br />

This section lists technical information about the <strong>2102</strong> <strong>Module</strong>.<br />

• Table 2-2 lists the technical specifications of the <strong>2102</strong>.<br />

• Table 2-3 lists the technical specifications of the Spread<br />

Spectrum Radio.<br />

• Table 2-4 lists the technical specifications of the 2191<br />

Battery <strong>Module</strong> which must be used with the Model<br />

<strong>2102</strong>.<br />

• Figure 2-2 and Table 2-5 list information about the <strong>2102</strong><br />

<strong>Module</strong>’s communication connector.<br />

Item No.<br />

Fig. 2-1<br />

Table 2-1 Controls, Connectors, and Indicators – <strong>2102</strong> <strong>Module</strong><br />

Name<br />

1 Communication<br />

Connector<br />

Description<br />

Upper communication port. The connection transfers data and 12 VDC power<br />

to other modules. The port may also be used to connect attached modules to<br />

a PC running Flowlink software.<br />

2 Connector Caps Insert into unused communication connectors to terminate the network and<br />

protect them from moisture damage. When communication connectors are in<br />

use, the caps must be stowed as shown in Figure 2-1 to protect the terminating<br />

components inside the caps.<br />

3 Communication Illuminates when the module is active.<br />

Indicator<br />

4 Latch Release Push in to release the module from a stack.<br />

5 Latch Push in to lock the module in a stack.<br />

6 Serial Number Label In back - lists product ID and unit serial numbers.<br />

7 Communication<br />

Connector<br />

Lower communication port. The connector transfers data and 12 VDC power<br />

to other modules.<br />

Table 2-2 Technical Specifications – <strong>2102</strong> <strong>Module</strong><br />

Size (HWD) 2.9 11.3 7.5 in. 7.4 28.7 19.1 cm<br />

Weight 2.0 lbs 0.9 kg<br />

Material<br />

High-impact molded polystyrene<br />

Enclosure (self-certified) NEMA 4X, 6P IP 68<br />

Power<br />

Typical Battery Life (one module)<br />

Carrier Detect Cycle Time<br />

Average Connection Time<br />

10.2 to 16.6 VDC, 100 mA typical at 12 VDC, 1 mA standby<br />

Typical: 50 days (when using two alkaline batteries)<br />

4 minutes<br />

2 minutes<br />

Operating Temperature 0° to 140°F -18° to 60°C<br />

Storage Temperature -40° to 140°F -40° to 60°C<br />

2-4