10 kg/cm2. Total Qty 35 mtr (n) 12 in nos. S/W system Cu Ni p0ipes/ 32 dia / 4.5 Kg / Cm2. Total Qty10 mtr (p) 22 in nos. Air system MS pipes/ 20/10.5kg/cm2. Total Qty 30 mtr DEPT: QC(E) C. No 74 SHIP: FC MADHUR NAVAL DOCKYARD, MUMBAI QUALITY ASSURANCE PLAN REV DATE: 23 May 12 FORM Q C E 0 7 4 R E 0 1 0 No:01 NO JOB TITLE :REFIT QAP No : QCE74 245 QAP DATE : 11JUL12 PAGE 15 OF22 Activity Description Remove the Pipes (328 Nos. ) from their location prior permission of ss. Manually clean the pipes, subsequently chemical cleaning. Post chemical cleaning the pipes to be offered for opening inspection. On recommendation of QC rep the pipes to be repaired by using original line material. S/W system and Fire main system pipes must be repaired/ renewed by MS (hot dip galvanized) pipes. Pipes to be hydro pressure tested at 1.5 times of working pressure of the system. Post pressure testing all pipes to be painted by oil paint as per systems color code. Pipes to be fitted back in place by using new Gaskets and Fasteners. Secure the pipes. The system to be Leak tested. E20029 Defect Description The following Water valves to be removed, Overhauled, Pressure tested and fitted back.{size (In mm)/Test Pr (in Kg/Cm2).} MaterialGun Metal. (a) Both main sea suction SDNR valve 80/ 3.5 kg/cm2 Qty 02 (b) Both main sea suction SDSL valve 80/ 3.5 kg/cm2 Qty 02 (c) Both sea chest air release SD valve 40/ 3.5 kg/cm2 Qty 02 (d) Both sea chest weed cleaning Air Valve 20/ 10.5 kg/cm2 Qty 02 (e) Both M/E S/W pump suction (N/R) Valve 50/ 3.5 1 3 3 DYT/INCOD/1213/106(a)/PLYCM/MADHURREFIT/420 98/127
kg/cm2 Qty 02 (f) Both M/E S/W suction 3 way plug Valve 50/ 3.5 kg/cm2 Qty 04 (g) Both M/E S/W pump delivery valve 40/ 4.5 kg/cm2 Qty 02 (h) M/E Inter cooler inlet and outlet valve 40/4.5 kg/cm2 Qty 02 DEPT: QC(E) C. No 74 SHIP: FC MADHUR NAVAL DOCKYARD, MUMBAI QUALITY ASSURANCE PLAN REV DATE: 23 May 12 FORM Q C E 0 7 4 R E 0 1 0 No:01 NO JOB TITLE :REFIT QAP No : QCE74 245 QAP DATE : 11JUL12 PAGE 16 OF22 (j) Both M/E Emergency cooling SDNR valve 40/ 4.5 kg/cm2 Qty 02 (k) D/G SW pumps suc/emg. cooling/ overboard SDNR valve 32/ 4.5 kg/cm2 Qty 02 (l) Both M/E S/W pump overboard discharge valve (SDNR)/ 40/ 4.5 kg/cm2 Qty 02 (m) G.S pump & bilge Pump suction and discharge valve 50/4.5 kg/cm2 Qty 04 (n) Both M/E F/W pp suction valve 50/4.5 kg/cm2 Qty 02 (p) Both M/E F/W drain valve 25/4.5 kg/cm2 Qty 02 (q) Both M/E F/W cooler drain valve 25/ 4.5 kg/cm2 Qty 02 (r) Both M/E & DG Spring loaded fire safe fuel line valve/Fuel Storage Tank Valve15/ 03 kg/cm2 Qty 05 (s) G.S pump valve chest (01 nos x 06 valves on chest)/50/06/ 4.5 kg/cm2 Qty 06 (t) Bilge pump valve chest (02 No's x 03 valves on each) 50/ 4.5 kg/cm2 Qty 06 (u) Fire main line valve/ GS Pump system valve 50/ 07 kg/cm2 Qty 04 (v) Fire hydrant valve 32/ 07 kg/cm2 Qty 12 (w) Fuel filling valve 50/ 3.5 kg/cm2 Qty 02 DYT/INCOD/1213/106(a)/PLYCM/MADHURREFIT/420 99/127
- Page 47 and 48: overhauled and tested onboard, (e)
- Page 49 and 50: (b) control panel defective to be o
- Page 51 and 52: (e) (f) Total VAT @______% (if appl
- Page 53 and 54: epair of ships or boats or vessels
- Page 55 and 56: machine, measuring instruments, Oxy
- Page 57 and 58: NAVAL DOCKYARD MUMBAI DOC CODE Q C
- Page 59 and 60: suitable for DP Test approved equiv
- Page 61 and 62: 25 Fairleads,Ventilation trunking e
- Page 63 and 64: followed 37 Provision of material t
- Page 65 and 66: DYT/INCOD/1213/106(a)/PLYCM/MAD
- Page 67 and 68: NAVAL DOCKYARD, MUMBAI TITLE : QUAL
- Page 69 and 70: i) Check for meters serviceability,
- Page 71 and 72: efurbishment, new installation and
- Page 73 and 74: 11 Repair, Overhauling, refurbishme
- Page 75 and 76: of Wall mounted fan 16 Overhauling,
- Page 77 and 78: commissioning / testing of Oily wat
- Page 79 and 80: 25 Carbon brushes, brush holder, Ro
- Page 81 and 82: SCOPE OF WORK P R W H vi) Check for
- Page 83 and 84: DEPT: QC(E) C. No 74 SHIP: FC MADHU
- Page 85 and 86: E20006 Defect Description If clea
- Page 87 and 88: DEPT: QC(E) C. No 74 SHIP: FC MADHU
- Page 89 and 90: DEPT: QC(E) C. No 74 SHIP: FC MADHU
- Page 91 and 92: pump post Overhauling. Make FloRi
- Page 93 and 94: DEPT: QC(E) C. No 74 SHIP: FC MADHU
- Page 95 and 96: DEPT: QC(E) C. No 74 SHIP: FC MADHU
- Page 97: DEPT: QC(E) C. No 74 SHIP: FC MADHU
- Page 101 and 102: 65 mm, Mat Steel, TP 3.0 kg/cm2
- Page 103 and 104: new flanges. Hot bending is not per
- Page 105 and 106: Activity Description Remove the cou
- Page 107 and 108: ARTICLE 14 INDEMNITY & INSURANCE
- Page 109 and 110: ARTICLE 2 EFFECTIVE DATE AND OPE
- Page 111 and 112: 5.2 “END USER” CERTIFICATE. Con
- Page 113 and 114: Certificate (applicable in the case
- Page 115 and 116: ARTICLE 14 INDEMNITY & INSURANCE
- Page 117 and 118: procuring the Contracts or forbeari
- Page 119 and 120: (c) Control generation and disposal
- Page 121 and 122: ANNEX 2 to Encl - III to RFP SCOP
- Page 123 and 124: DESIGNATION / RANK DEPT/ORGANISATIO
- Page 125 and 126: ‘T’ BID COMPLIANCE MATRIX (TO B
- Page 127: Enclosure VII of RFP EMD Bank Guara
kg/cm2 Qty 02<br />
(f) Both M/E S/W suction 3 way plug Valve 50/ 3.5<br />
kg/cm2 Qty 04<br />
(g) Both M/E S/W pump delivery valve 40/ 4.5<br />
kg/cm2 Qty 02<br />
(h) M/E Inter cooler <strong>in</strong>let and outlet valve 40/4.5<br />
kg/cm2 Qty 02<br />
DEPT: QC(E) C. No<br />
74<br />
SHIP: FC MADHUR<br />
NAVAL DOCKYARD, MUMBAI<br />
QUALITY ASSURANCE PLAN<br />
REV DATE: 23 May 12 FORM Q C E 0 7 4 R E 0 1 0<br />
No:01<br />
NO<br />
JOB TITLE :REFIT<br />
QAP No : QCE74 245 QAP DATE : 11JUL12 PAGE 16 OF22<br />
(j) Both M/E Emergency cool<strong>in</strong>g SDNR valve 40/<br />
4.5 kg/cm2 Qty 02<br />
(k) D/G SW pumps suc/emg. cool<strong>in</strong>g/ overboard<br />
SDNR valve 32/ 4.5 kg/cm2 Qty 02<br />
(l) Both M/E S/W pump overboard discharge valve<br />
(SDNR)/ 40/ 4.5 kg/cm2 Qty 02<br />
(m) G.S pump & bilge Pump suction and discharge<br />
valve 50/4.5 kg/cm2 Qty 04<br />
(n) Both M/E F/W pp suction valve 50/4.5 kg/cm2<br />
Qty 02<br />
(p) Both M/E F/W dra<strong>in</strong> valve 25/4.5 kg/cm2 Qty 02<br />
(q) Both M/E F/W cooler dra<strong>in</strong> valve 25/ 4.5 kg/cm2<br />
Qty 02<br />
(r) Both M/E & DG Spr<strong>in</strong>g loaded fire safe fuel l<strong>in</strong>e<br />
valve/Fuel Storage Tank Valve15/ 03 kg/cm2 Qty<br />
05<br />
(s) G.S pump valve chest (01 nos x 06 valves on<br />
chest)/50/06/ 4.5 kg/cm2 Qty 06<br />
(t) Bilge pump valve chest (02 No's x 03 valves on<br />
each) 50/ 4.5 kg/cm2 Qty 06<br />
(u) Fire ma<strong>in</strong> l<strong>in</strong>e valve/ GS Pump system valve 50/<br />
07 kg/cm2 Qty 04<br />
(v) Fire hydrant valve 32/ 07 kg/cm2 Qty 12<br />
(w) Fuel fill<strong>in</strong>g valve 50/ 3.5 kg/cm2 Qty 02<br />
DYT/INCOD/1213/106(a)/PLYCM/MADHURREFIT/420 99/127