Torque transducer Data sheet

Torque transducer Data sheet

Torque transducer Data sheet

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Specifications (continued)<br />

Nominal (rated) torque M nom N⋅m 5 10 20 50 100 200 500<br />

kN⋅m 1<br />

General data<br />

EMC 2)<br />

Immunity from interference<br />

(DIN EN 61326−1 / EN 61000−6)<br />

Enclosure<br />

HF line interference<br />

150 kHZ − 80 MHz (AM)<br />

ESD (electrostatic discharge)<br />

Enclosure<br />

Electromagnetic field<br />

80 MHz − 1000 MHz (AM)<br />

1400 MHz − 2700 MHz (AM)<br />

V<br />

kV<br />

kV<br />

V/m<br />

V/m<br />

10 / A<br />

Air 8 / A<br />

Contact 4 / A<br />

10 / A<br />

3 / A<br />

Lines − Connecting cable<br />

Burst (fast transients) kV 2 / A<br />

Emission (EME) (EN 61326-1 / EN 55011)<br />

RFI voltage<br />

(interference voltage at DC mains connection)<br />

RFI field strength<br />

−<br />

−<br />

Class B (150 kHz − 30 MHz)<br />

Class B (30 MHz − 1000 MHz)<br />

(Electromagnetic RFI field strength)<br />

Degree of protection per EN 60529 IP 40<br />

Nominal (rated) temperature range °C [°F] +5...+45 [+41...+113]<br />

Operating temperature range °C [°F] 0...+60 [+32...+140]<br />

Storage temperature range °C [°F] −5...+70 [+23...+158]<br />

Impact resistance, test severity level per<br />

DIN IEC 68; Part 2-27; IEC 68-2-29-1987<br />

number n 1000<br />

duration ms 3<br />

acceleration (halfsine) m/s 2 650<br />

Vibration resistance, test severity level<br />

per DIN IEC 68, Part 2-6: IEC 68-2-6-1982<br />

frequency range Hz 5 ... 65<br />

duration h 1.5<br />

acceleration (amplitude) m/s 2 50<br />

Nominal (rated) rotational speed n nom min -1 16 000 12 000 9 000<br />

Load limits 3)<br />

Limit torque, related to M nom % 200 5)<br />

Breaking torque, related to M nom % > 280<br />

Longitudinal limit force kN 0.9 0.9 0.9 1.6 1.6 1.6 4 4<br />

Lateral limit force N 25 45 90 210 420 850 1400 2800<br />

Bending limit moment N⋅m 0.5 0.9 1.9 5.5 11 22 54 109<br />

Oscillation width per DIN 50100 (peak-topeak)<br />

4) %<br />

80<br />

2) Test severity / criterion: Industrial environment, cable length 30 m. Application not outside buildings.<br />

3) Each type of irregular stress (bending moment, lateral or longitudinal force, exceeding nominal (rated) torque) can only be permitted up to its<br />

specified static load limit provided none of the others can occur at the same time. If this condition is not met, the limit values must be<br />

reduced. If 30% of the bending limit moment and lateral limit force occur at the same time, only 40% of the longitudinal limit force is<br />

permissible and the nominal (rated) torque must not be exceeded. The permissible bending moments, longitudinal forces and lateral forces<br />

can affect the measurement result by approx. 1 % of the nominal (rated) torque.<br />

4) The nominal (rated) torque must not be exceeded.<br />

5) Please adhere to the maximum torque (T max ) of the couplings.<br />

B2318-2.0 en<br />

3<br />